Response to aspirin in healthy individuals Cross-comparison of light transmission aggregometry, VerifyNow system, platelet count drop, thromboelastography (TEG) and urinary 11-dehydrothromboxane B2

被引:63
|
作者
Blais, Normand [1 ,3 ]
Pharand, Chantal [2 ,4 ,5 ]
Lordkipanidze, Marie [2 ,4 ,5 ]
Sia, Ying K. [4 ]
Merhi, Yahye [7 ]
Diodati, Jean G. [3 ,4 ,6 ]
机构
[1] Hop Notre Dame de Bon Secours, CHUM, Hematol & Blood Bank Dept, Montreal, PQ H2L 4M1, Canada
[2] Hop Sacre Coeur, Fac Pharm, Montreal, PQ H4J 1C5, Canada
[3] Univ Montreal, Fac Med, Montreal, PQ H3C 3J7, Canada
[4] Hop Sacre Coeur, Res Ctr, Montreal, PQ H4J 1C5, Canada
[5] Hop Sacre Coeur, Dept Pharm, Montreal, PQ H4J 1C5, Canada
[6] Hop Sacre Coeur, Div Cardiol, Montreal, PQ H4J 1C5, Canada
[7] Montreal Heart Inst, Res Ctr, Montreal, PQ H1T 1C8, Canada
关键词
Agregometry; aspirin; thromboelastography; thromboxane; VerifyNow; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR EVENTS; ARACHIDONIC-ACID; PRIMARY PREVENTION; TREATED PATIENTS; FUNCTION ASSAY; HIGH-RISK; RESISTANCE; METAANALYSIS; AGGREGATION;
D O I
10.1160/TH09-02-0126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Variable biological effect of aspirin is suggested to be related to pharmacological resistance. The incidence of this so-called "resistant" state varies with the study population and the assay used. We determined performance features of five assays used to assess aspirin effects in non-smoking healthy volunteers not taking any drug known to interfere with platelet function. Blood and urine samples were obtained immediately before and after 8-10 days of aspirin 80 mg intake. Forty-five participants 19-59 years old were enrolled. The sensitivity (SE), specificity (SP), and optimal cut-off (CO) value to detect the effect of aspirin were: light transmission aggregometry (LTA) with 1.6 mM arachidonic acid (AA) - SE 100%, SP 95.9%, CO 20%; LTA with adenosine diphosphate (ADP) 10 mu M - SE 84.4%, SP 77.8%, CO 70%;VerifyNow(R) Aspirin - SE 100%, SP 95.6%, CO 550 ARU; platelet count drop - SE 82.2%, SP 86,7%, CO 55%;TEG(R) - SE 82,9%, SP 75,8%, CO 90%; and urinary 11-dehydrothromboxane B-2 levels (11-dHTB(2)) - SE 62.2%, SP 82.2%, CO 60 pg/ml. AA-induced LTA and the VerifyNow(R) assay reliably detected aspirin intake in all subjects; there was wide overlap in pre- and post-aspirin results with ADP-induced LTA, platelet count drop,TEG(R) and urinary 11-dHTB(2) assays. These results suggest that some of the variability in the reported incidence of "aspirin resistance" is unrelated to aspirin intake but related to inherent limitations of some assays to detect aspirin mediated effects or to underlying platelet reactivity variability independent of aspirin-mediated cyclooxygenase-1 inhibition.
引用
收藏
页码:404 / 411
页数:8
相关论文
共 4 条
  • [1] Comparison of Aspirin Response Measured by Urinary 11-Dehydrothromboxane B2 and VerifyNow Aspirin Assay in Patients with Ischemic Stroke
    Dharmasaroja, Pornpatr A.
    Sae-Lim, Suvaraporn
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (05) : 953 - 957
  • [2] Comparison between a new platelet count drop method PL-11, light transmission aggregometry, VerifyNow aspirin system and thromboelastography for monitoring short-term aspirin effects in healthy individuals
    Guan, Jie
    Cong, Yulong
    Ren, Junwei
    Zhu, Yuan
    Li, Li
    Deng, Xinli
    Bai, Jie
    PLATELETS, 2015, 26 (01) : 25 - 30
  • [3] Comparison between urinary 11-dehydrothromboxane B2 detection and platelet Light Transmission Aggregometry (LTA) assays for evaluating aspirin response in elderly patients with coronary artery disease
    Liu, Tengfei
    Zhang, Jingwei
    Chen, Xiahuan
    Feng, Xueru
    Fu, Sidney W.
    McCaffrey, Timothy A.
    Liu, Meilin
    GENE, 2015, 571 (01) : 23 - 27
  • [4] Effects of different doses, enteric-coated preparation of aspirin, and sex on urinary 11-dehydrothromboxane B2 in healthy volunteers
    Dharmasaroja, Pornpatr A.
    Sae-Lim, Suvaraporn
    BLOOD COAGULATION & FIBRINOLYSIS, 2010, 21 (07) : 649 - 652