Square-wave voltammetric stripping analysis of thallium(III) at a poly(4-vinylpyridine)/mercury film electrode

被引:20
|
作者
Zen, JM
Wu, JW
机构
[1] Department of Chemistry, National Chung-Hsing University, Taichung
关键词
thallium; square-wave anodic stripping voltammetry; mercury film electrode; poly(4-vinylpyridine);
D O I
10.1002/elan.1140090408
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A poly(4-vinylpyridine)/mercury film electrode (PVP/MFE) was used for the determination of trace thallium(III) by square-wave anodic stripping voltammetry (SWASV). Thallium(III) is preconcentrated onto the PVP/MFE as the anionic forms in chloride medium by the ion-exchange effect of the PVP. The high solubility of thallium in mercury further facilitates the accumulation effect. Various factors influencing the determination of thallium(III) were thoroughly investigated. This modified electrode displayed good resistance to interferences from surface-active compounds and common ions and increased sensitivity when used in conjunction with SWASV. In addition, detection can be achieved without deoxygenation and the electrode can be easily renewed. Applicability to various water samples is illustrated.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 27 条
  • [1] Potentiometric stripping analysis of traces of thallium(III) at a poly(4-vinylpyridine)/mercury film electrode
    Zen, JM
    Wang, WM
    Kumar, AS
    ELECTROANALYSIS, 2001, 13 (04) : 321 - 324
  • [2] Square-wave anodic stripping voltammetric determination of thallium(I) at a Nafion mercury film modified electrode
    Lu, TH
    Yang, HY
    Sun, IW
    TALANTA, 1999, 49 (01) : 59 - 68
  • [3] Anodic stripping voltammetric determination of thallium(III) using a Tosflex/mercury film electrode
    Lu, TH
    Sun, IW
    ELECTROANALYSIS, 1998, 10 (15) : 1052 - 1056
  • [4] SQUARE-WAVE VOLTAMMETRIC DETERMINATION OF COPPER(II) WITH A NAFION DIMETHYLGLYOXIME MERCURY-FILM ELECTRODE
    ZEN, JM
    CHI, NY
    HSU, FS
    CHUNG, MJ
    ANALYST, 1995, 120 (02) : 511 - 515
  • [5] Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder
    Lee, Gyroung-Ja
    Lee, Hi Min
    Uhm, Young Rang
    Lee, Min Ku
    Rhee, Chang-Kyu
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (12) : 1920 - 1923
  • [6] In situ bismuth-film electrode for square-wave anodic stripping voltammetric determination of tin in biodiesel
    Frena, Morgana
    Campestrini, Iolana
    de Braga, Otoniel C.
    Spinelli, Almir
    ELECTROCHIMICA ACTA, 2011, 56 (12) : 4678 - 4684
  • [7] Selective voltammetric determination of lead(II) on partially quaternized poly(4-vinylpyridine)/mercury film electrodes
    Zen, JM
    Chung, HH
    Ilangovan, G
    ELECTROANALYSIS, 1999, 11 (02) : 108 - 113
  • [8] Square-wave stripping voltammetry with thin mercury-film ultramicroelectrodes
    Jin, JY
    Kinugasa, K
    Takeuchi, T
    Miwa, T
    BUNSEKI KAGAKU, 1998, 47 (06) : 349 - 354
  • [9] Sensitive determination of zinc(II) in real samples using a poly(4-vinylpyridine)/mercury film electrode
    Zen, JM
    Tsai, DM
    Yang, HH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2003, 50 (3A) : 375 - 380
  • [10] A STUDY OF RIBOFLAVIN DETERMINATION BY SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES
    ECONOMOU, A
    FIELDEN, PR
    ELECTROANALYSIS, 1995, 7 (05) : 447 - 453