Likelihood of total resolution in liquid chromatography: Evaluation of one-dimensional, comprehensive two-dimensional, and selective comprehensive two-dimensional liquid chromatography

被引:25
作者
Davis, Joe M. [1 ]
Stoll, Dwight R. [2 ]
机构
[1] So Illinois Univ, Dept Chem & Biochem, Carbondale, IL 62901 USA
[2] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
关键词
Two-dimensional; Liquid chromatography; Comprehensive; Selective comprehensive; Heartcutting; Resolution; EFFECTIVE PEAK-CAPACITY; MULTICOMPONENT CHROMATOGRAMS; MULTIDIMENSIONAL SEPARATION; RESOLVING POWER; PERFORMANCE; 1ST-DIMENSION; OVERLAP; ORTHOGONALITY; PARAMETERS; PRESSURE;
D O I
10.1016/j.chroma.2014.07.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Computer simulations of three methods of liquid chromatography (LC) are developed to understand better the conditions under which each method is superior to the others. The methods are one-dimensional LC (1D-LC), comprehensive two-dimensional LC (LC x LC), and selective comprehensive two-dimensional LC (sLC x LC). The criterion by which superiority is measured in this case is the probability that all peaks in a given sample are separated by a resolution equaling or exceeding unity. A point-process model is developed for the simulation of sLC x LC to complement existing models for 1D-LC and LC x LC. In the sLC x LC model, first-dimension singlet peaks remain in that dimension, and first-dimension multiplets, or clusters of overlapping peaks, are transferred to the second dimension for further separation during the interval of time between successive multiplets. Criteria are developed for the success or failure of multiplet transfer. The three LC methods are simulated for peak numbers ranging from 2 to 50 and analysis times ranging from 10 to 1200 s, using peak capacities that reflect the performance of modern instrumentation. The probability computations predict the experimental finding that LC x LC is superior to 1D-LC at long times (over 210 or so seconds) but is inferior at shorter times due to the broadening of first-dimension peaks by sampling. In general, sLC x LC is predicted to be superior to LC x LC for samples with less than 40 peaks separated using three samples or less per multiplet. Conversely, LC x LC is predicted to be superior to sLC x LC for samples containing more than 40 peaks and when sLC x LC separations are carried out with six samples per multiple. We find that the analysis time required to attain a 50% probability of total resolution is always predicted to be shorter for sLC x LC than for 1D-LC, and 30-75% shorter than for LC x LC when 20 or so peaks are separated. Finally, in light of the substantial predicted time savings for sLC x LC analyses the computations are interpreted relative to practical concerns, e.g., retention-time shifts, to establish good working conditions (e.g., the number of samples per multiplet) for future experimental studies of sLC x LC. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 142
页数:15
相关论文
共 31 条
[1]   Accumulating resampling (modulation) in comprehensive two-dimensional capillary GC (GC x GC) [J].
Blumberg, Leonid M. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (19) :3358-3365
[2]   Effect of Pressure, Particle Size, and Time on Optimizing Performance in Liquid Chromatography [J].
Carr, Peter W. ;
Wang, Xiaoli ;
Stoll, Dwight R. .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5342-5353
[3]   ORIGIN AND CHARACTERIZATION OF DEPARTURES FROM THE STATISTICAL-MODEL OF COMPONENT-PEAK OVERLAP IN CHROMATOGRAPHY [J].
DAVIS, JM ;
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :277-298
[4]   Statistical-overlap theory for elliptical zones of high aspect ratio in comprehensive two-dimensional separations [J].
Davis, JM .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (04) :347-359
[5]   Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[6]   A quantitative theory of the statistical degree of peak overlapping in chromatography [J].
Dondi, F ;
Bassi, A ;
Cavazzini, A ;
Pietrogrande, MC .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :766-773
[7]   FOURIER-ANALYSIS OF MULTICOMPONENT CHROMATOGRAMS - NUMERICAL EVALUATION OF STATISTICAL PARAMETERS [J].
FELINGER, A ;
PASTI, L ;
RESCHIGLIAN, P ;
DONDI, F .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1854-1860
[8]   Orthogonality of separation in two-dimensional liquid chromatography [J].
Gilar, M ;
Olivova, P ;
Daly, AE ;
Gebler, JC .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6426-6434
[9]   Selective comprehensive multidimensional separation for resolution enhancement in high performance liquid chromatography. Part II: Applications [J].
Groskreutz, Stephen R. ;
Swenson, Michael M. ;
Secor, Laura B. ;
Stoll, Dwight R. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :41-50
[10]   Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentation [J].
Groskreutz, Stephen R. ;
Swenson, Michael M. ;
Secor, Laura B. ;
Stoll, Dwight R. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :31-40