Direct Comparison of Point-by-Point and Rapid Ultra-High-Resolution Electroanatomical Mapping in Patients Scheduled for Ablation of Atrial Fibrillation

被引:26
作者
Rottner, Laura [1 ]
Metzner, Andreas [1 ]
Ouyang, Feifan [1 ]
Heeger, Christian [1 ]
Hayashi, Kentaro [1 ]
Fink, Thomas [1 ]
Lemes, Christine [1 ]
Mathew, Shibu [1 ]
Maurer, Tilman [1 ]
Reissmann, Bruno [1 ]
Rexha, Enida [1 ]
Riedl, Johannes [1 ]
Saguner, Ardan M. [1 ]
Santoro, Francesco [1 ]
Kuck, Karl-Heinz [1 ]
Sohns, Christian [1 ]
机构
[1] Asklepios Klin St Georg, Dept Cardiol, Lohmuhlenstr 5, D-20099 Hamburg, Germany
关键词
atrial fibrillation; Carto system; catheter ablation; electroanatomic mapping; Rhythmia system; PULMONARY VEIN ISOLATION; CATHETER ABLATION; IMAGE INTEGRATION; CLINICAL-EXPERIENCE; EUROPEAN-SOCIETY; BASKET CATHETER; CARDIOLOGY ESC; TASK-FORCE; FOLLOW-UP; SYSTEM;
D O I
10.1111/jce.13160
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Point-by-Point versus Rapid Ultra-High-Resolution Electroanatomical Mapping in AF IntroductionThree-dimensional electroanatomical mapping (EAM) is an established tool facilitating catheter ablation. In this context, the novel Rhythmia system sets a new bar in fast high-resolution mapping. The aim of this study was to directly compare point-by-point versus rapid ultra-high-resolution EAM in patients scheduled for ablation of atrial fibrillation (AF) with focus on procedural data, acute success, and midterm clinical outcome. Methods and ResultsA total number of 74 consecutive patients (48/74 male) with symptomatic AF were scheduled to undergo pulmonary vein isolation (PVI) using either Carto or Rhythmia. The Carto-guided procedures were performed using point-by-point acquisition according to our routine approach, whereas for Rhythmia, fast anatomical mapping was utilized. Comparing Rhythmia- versus Carto-guided ablation approaches, we observed a significantly longer total mapping time (P = 0.001), longer total fluoroscopy time (P = 0.001), more delivered RF-applications (P = 0.019), and longer total RF-duration (P = 0.002). There was no difference regarding total ablation time (P = 0.707), total procedure duration (P = 0.99), and acute procedural success. During follow-up, 84.8% of patients remained free from any AF/AT-recurrence using Carto versus 88.2% when using Rhythmia (P = 0.53). From Kaplan-Meier analysis, the event rate estimations were 15% versus 13.5%, respectively. ConclusionThe present study reports our first clinical experience using Rhythmia in direct comparison with the established Carto system for AF ablation. Our data clearly demonstrate that Rhythmia was proved to be effective and well applicable but more data will be mandatory before final conclusions can be drawn.
引用
收藏
页码:289 / 297
页数:9
相关论文
共 27 条
[1]   Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter [J].
Anter, Elad ;
Tschabrunn, Cory M. ;
Contreras-Valdes, Fernando M. ;
Li, Jianqing ;
Josephson, Mark E. .
HEART RHYTHM, 2015, 12 (09) :1927-1934
[2]   Mechanisms of Atrial Fibrillation Rotors, Ionic Determinants, and Excitation Frequency [J].
Berenfeld, Omer ;
Jalife, Jose .
HEART FAILURE CLINICS, 2016, 12 (02) :167-+
[3]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[4]  
Camm AJ, 2010, EUR HEART J, V31, P2369, DOI [10.1093/eurheartj/ehq278, 10.1093/europace/euq350]
[5]   Image Integration-Guided Catheter Ablation of Atrial Fibrillation: A Prospective Randomized Study [J].
Della Bella, Paolo ;
Fassini, Gaetano ;
Cireddu, Manuela ;
Riva, Stefania ;
Carbucicchio, Corrado ;
Giraldi, Francesco ;
Maccabelli, Giuseppe ;
Trevisi, Nicola ;
Moltrasio, Massimo ;
Pepi, Mauro ;
Galli, Claudia A. ;
Andreini, Daniele ;
Ballerini, Giovanni ;
Pontone, Gianluca .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) :258-265
[6]  
Ernst Sabine, 2015, Card Electrophysiol Clin, V7, P117, DOI 10.1016/j.ccep.2014.11.007
[7]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[8]   Response to Letter Regarding Article, "Ablation of Persistent Atrial Fibrillation Targeting Low-Voltage Areas With Selective Activation Characteristics" [J].
Jadidi, Amir S. ;
Lehrmann, Heiko ;
Keyl, Cornelius ;
Sorrel, Jeremie ;
Markstein, Viktor ;
Minners, Jan ;
Park, Chan-il ;
Denis, Arnaud ;
Jais, Pierre ;
Hocini, Meleze ;
Potocnik, Clemens ;
Allgeier, Juergen ;
Hochholzer, Willibald ;
Herrera-Siklody, Claudia ;
Kim, Steve ;
El Omri, Youssef ;
Neumann, Franz-Josef ;
Weber, Reinhold ;
Haissaguerre, Michel ;
Arentz, Thomas .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (07)
[9]   A multi-purpose spiral high-density mapping catheter: initial clinical experience in complex atrial arrhythmias [J].
Jones, David Gareth ;
McCready, James W. ;
Kaba, Riyaz A. ;
Ahsan, Syed Y. ;
Lyne, Jonathan C. ;
Wang, Jack ;
Segal, Oliver R. ;
Markides, Vias ;
Lambiase, Pier D. ;
Wong, Tom ;
Chow, Anthony W. C. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 31 (03) :225-235
[10]   Contact Electroanatomic Mapping Derived Voltage Criteria for Characterizing Left Atrial Scar in Patients Undergoing Ablation for Atrial Fibrillation [J].
Kapa, Suraj ;
Desjardins, Benoit ;
Callans, David J. ;
Marchlinski, Francis E. ;
Dixit, Sanjay .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (10) :1044-1052