Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes

被引:0
作者
Baldini, E
Dall'Orto, VC
Danilowicz, C
Rezzano, I
Calvo, EJ
机构
[1] INQUIMAE, Dept Quim Inorgan Analit & Quim Fis, Fac Ciencias Exactas & Nat, AR-1428 Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Farm & Bioquim, AR-1113 Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
biosensor; peroxide; enzyme; HRP; biomimetic; porphyrin;
D O I
10.1002/1521-4109(200209)14:17<1157::AID-ELAN1157>3.0.CO;2-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors designed with crosslinked redox hydrogel and horseradish peroxidase have been evaluated in aqueous and nonaqueous media. Electrodes made of a single layer of active material were prepared with Os(bYP)(2)ClPyCH2 NHPoly(allylamine) polymer, (PAA-Os), attached to the enzyme by PEG-400 bifunctional reagent with the Os sites acting as electron wires. The electrodes proved to be stable in the presence of organic solvent considering the time evolution of the redox charge and the catalytic current. However, a reasonable decrease in the enzyme response is apparent while increasing solvent content in solution for detection of hydrogen and lauroyl peroxide. As an alternative biomimetic strategy, electrodes were modified with consecutive layers of PAA-Os and electropolymerized Fe-protoporphyrin IX. The electrochemical detection of peroxides was also possible with this system, proving that the poly[Fe-protoporphyrin IX]/Osmium complex system can mimic the peroxidase activity towards hydrogen and organic peroxides. The replacement of Fe-protoporphyrin by Ni-protoporphyrin IX and PAA-Os by PAA in different experiments demonstrates that the mechanism for peroxide reduction involves both Os and Fe-protoporphyrin IX sites. The enzymatic electrodes were applied to benzoyl peroxide quantitation in a pharmaceutical product. The method validation demonstrates that a simple and rapid FIA detection can be applied.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
[41]   Detection of Trace Heavy Metal Ions Using Carbon Nanotube-Modified Electrodes [J].
Morton, Jeffrey ;
Havens, Nathaniel ;
Mugweru, Amos ;
Wanekaya, Adam K. .
ELECTROANALYSIS, 2009, 21 (14) :1597-1603
[42]   Electrosynthesis of a new enzyme-modified electrode for the amperometric detection of glucose [J].
Piro, B ;
Do, VA ;
Le, LA ;
Hedayatullah, M ;
Pham, MC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 486 (02) :133-140
[43]   An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres [J].
Zhang, Hai-Li ;
Lai, Guo-Song ;
Han, De-Yan ;
Yu, Ai-Min .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) :971-977
[44]   Glassy carbon electrodes modified with hemin-carbon nanomaterial films for amperometric H2O2 and NO2- detection [J].
Valentini, Federica ;
Cristofanelli, Lara ;
Carbone, Marilena ;
Palleschi, Giuseppe .
ELECTROCHIMICA ACTA, 2012, 63 :37-46
[45]   Label-free amperometric immunosensor based on prussian blue as artificial peroxidase for the detection of methamphetamine [J].
Zhang, Ling-Yan ;
Liu, Yan-Jun .
ANALYTICA CHIMICA ACTA, 2014, 806 :204-209
[46]   Amperometric Hydrogen Peroxide Sensors with Multivalent Metal Oxide-Modified Electrodes for Biomedical Analysis [J].
Waryo, Tesfaye ;
Kotzian, Petr ;
Begic, Sabina ;
Bradizlova, Petra ;
Beyene, Negussie ;
Baker, Priscilla ;
Kgarebe, Boitumelo ;
Turkusic, Emir ;
Iwuoha, Emmanuel ;
Vytras, Karel ;
Kalcher, Kurt .
13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3) :829-+
[47]   AMPEROMETRIC BIOSENSORS BASED ON ELECTROCATALYTIC REGENERATION OF NAD+ AT REDOX POLYMER-MODIFIED ELECTRODES [J].
PERSSON, B ;
LAN, HL ;
GORTON, L ;
OKAMOTO, Y ;
HALE, PD ;
BOGUSLAVSKY, LI ;
SKOTHEIM, T .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) :81-88
[48]   Preparation of carbon paste electrodes including poly(styrene) attached glycine-Pt(IV) for amperometric detection of glucose [J].
Donmez, Soner ;
Arslan, Fatma ;
Sari, Nursen ;
Yetim, Nurdan Kurnaz ;
Arslan, Halit .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :146-150
[49]   Flow injection analysis of paracetamol using a biomimetic sensor as a sensitive and selective amperometric detector [J].
Oliveira, Mariana C. Q. ;
Lanza, Marcos R. V. ;
Tanaka, Auro A. ;
Sotomayor, Maria D. P. T. .
ANALYTICAL METHODS, 2010, 2 (05) :507-512
[50]   Amperometric sensor for detection of bisphenol A using a pencil graphite electrode modified with polyaniline nanorods and multiwalled carbon nanotubes [J].
Poorahong, Sujittra ;
Thammakhet, Chongdee ;
Thavarungkul, Panote ;
Limbut, Warakorn ;
Numnuam, Apon ;
Kanatharana, Proespichaya .
MICROCHIMICA ACTA, 2012, 176 (1-2) :91-99