Water quality monitoring of the Pirapo River watershed, Parana, Brazil

被引:9
作者
Bortoletto, E. C. [1 ]
Silva, H. A. [2 ]
Bonifacio, C. M. [3 ]
Tavares, C. R. G. [4 ]
机构
[1] UEM, Dept Agr Engn, Rodovia PR 482,Km 45,Bloco L025, BR-87820000 Cidade Gaucha, PR, Brazil
[2] Univ Estadual Maringa, Programa Posgrad Agron, Rodovia PR 482,Km 45,Bloco J45, BR-87020900 Maringa, Parana, Brazil
[3] Univ Estadual Maringa, Programa Posgrad Geog, Ave Colombo 5790,Bloco J12, BR-87020900 Maringa, Parana, Brazil
[4] Univ Estadual Maringa, Dept Engn Quim, Ave Colombo 5790,Bloco D90, BR-87020900 Maringa, Parana, Brazil
关键词
monitoring; water quality; Pirapo River; pollution; principal component analysis;
D O I
10.1590/1519-6984.00313suppl
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to evaluate the water quality of the Pirapo River watershed in Parana, Brazil, and identify the critical pollution sites throughout the drainage basin. The water quality was monitored during the period from January 2011 to December 2012. Nine points distributed throughout the main channel of the Pirapo River were sampled for a total of 17 samplings. The water quality was evaluated based on the determination of 14 physical, chemical and microbiological parameters. Analysis of the variables monitored in the Pirapo River watershed using factor analysis/principal components analysis (FA/PCA) indicated the formation of three distinct groups of parameters: water temperature (T-water), dissolved oxygen (DO) and a group composed of total suspended solids (TSS), turbidity and nitrite (NO2-). The parameters T-water and DO exhibited a relationship with the seasonality, and the TSS, turbidity, and NO2- levels were correlated with surface runoff caused by rainfall events. Principal component analysis (PCA) of the sampling points enabled the selection of the 10 most important variables from among the 14 evaluated parameters. The results showed that the nitrate (NO3-), NO2-, TSS, turbidity and total phosphorous (TP) levels were related to the soil type, and the parameters DO, electrical conductivity (EC), ammoniacal nitrogen (N-NH3) and thermotolerant coliforms (TC) were related to organic matter pollution, with the P5 sampling site being the most critical site. The ordination diagram of the sampling points as a function of the PCA indicated a reduction from 9 to 5 sampling points, indicating the potential for decreasing the costs associated with monitoring.
引用
收藏
页码:148 / 157
页数:10
相关论文
共 21 条
[1]  
Almeida S. G., 2001, CRISE SOCIOAMBIENTAL
[2]  
[Anonymous], 1989, STANDARD METHODS EXA, V17th
[3]  
AOAC, 1999, Official Methods of Analysis of AOAC International, DOI DOI 10.3109/15563657608988149
[4]  
Aprile Fabio Marques, 2001, Bioikos (Campinas), V15, P109
[5]   Water quality of the Chhoti Gandak River using principal component analysis, Ganga Plain, India [J].
Bhardwaj, Vikram ;
Sen Singh, Dhruv ;
Singh, A. K. .
JOURNAL OF EARTH SYSTEM SCIENCE, 2010, 119 (01) :117-127
[6]  
Carneiro PCS, 2012, BIOMETRIC MODELS APP, V1
[7]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond
[8]  
Companhia Ambiental do Estado de Sao Paulo-CETESB (Sao Paulo State Environmental Company), 2009, QUAL AG INT EST SAO
[9]  
FRANCA M.S., 2009, THESIS U FEDERAL PAR
[10]   Application of multivariate statistical analysis in the study of water quality in the Pomba River (MG) [J].
Guedes, Hugo A. S. ;
da Silva, Demetrius D. ;
Elesbon, Abrahao A. A. ;
Ribeiro, Celso B. M. ;
de Matos, Antonio T. ;
Soares, Jose H. P. .
REVISTA BRASILEIRA DE ENGENHARIA AGRICOLA E AMBIENTAL, 2012, 16 (05) :558-563