In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal-resolution β+-sensitive microprobe

被引:32
作者
Pain, F
Besret, L
Vaufrey, F
Grégoire, MC
Pinot, L
Gervais, P
Ploux, L
Bloch, G
Mastrippolito, R
Laniece, P
Hantraye, P [1 ]
机构
[1] Serv Hosp Frederic Joliot, CNRS 2210, URA 22B, CEA,Unite Rech Associee, F-91401 Orsay, France
[2] Inst Phys Nucl, F-91406 Orsay, France
[3] Serv Hosp Frederic Joliot, Isotop Imaging BIochem & Pharmacol Unit U12BP, F-91401 Orsay, France
[4] Serv Hosp Frederic Joliot, CEA, F-91401 Orsay, France
关键词
D O I
10.1073/pnas.162368899
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Understanding brain disorders, the neural processes implicated in cognitive functions and their alterations in neurodegenerative pathologies, or testing new therapies for these diseases would benefit greatly from combined use of an increasing number of rodent models and neuroimaging methods specifically adapted to the rodent brain. Besides magnetic resonance (MR) imaging and functional MR, positron-emission tomography (PET) remains a unique methodology to study in vivo brain processes. However, current high spatial-resolution tomographs suffer from several technical limitations such as high cost, low sensitivity, and the need of restraining the animal during image acquisition. We have developed a beta(+)-sensitive high temporal-resolution system that overcomes these problems and allows the in vivo quantification of cerebral biochemical processes in rodents. This beta-MICROPROBE is an in situ technique involving the insertion of a fine probe into brain tissue in a way very similar to that used for microdialysis and cell electrode recordings. In this respect, it provides information on molecular interactions and pathways, which is complementary to that produced by these technologies as well as other modalities such as MR or fluorescence imaging. This study describes two experiments that provide a proof of concept to substantiate the potential of this technique and demonstrate the feasibility of quantifying brain activation or metabolic depression in individual living rats with 2-[F-18]fluoro-2-deoxy-D-glucose and standard compartmental modeling techniques. Furthermore, it was possible to identify correctly the origin of variations in glucose consumption at the hexokinase level, which demonstrate the strength of the method and its adequacy for in vivo quantitative metabolic studies in small animals.
引用
收藏
页码:10807 / 10812
页数:6
相关论文
共 33 条
[1]   Metabolic compromise with systemic 3-nitropropionic acid produces striatal apoptosis in Sprague-Dawley rats but not in BALB/c ByJ mice [J].
Alexi, T ;
Hughes, PE ;
Knüsel, B ;
Tobin, AJ .
EXPERIMENTAL NEUROLOGY, 1998, 153 (01) :74-93
[2]   Sustained attenuation of the cerebrovascular response to a 10 min whisker stimulation following neuronal nitric oxide synthase inhibition [J].
Bonvento, G ;
Cholet, N ;
Seylaz, J .
NEUROSCIENCE RESEARCH, 2000, 37 (02) :163-166
[3]  
Brouillet E, 1998, J NEUROCHEM, V70, P794
[4]  
CARSON R E, 1986, P347
[5]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[6]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[7]   Local uncoupling of the cerebrovascular and metabolic responses to somatosensory stimulation after neuronal nitric oxide synthase inhibition [J].
Cholet, N ;
Seylaz, J ;
Lacombe, P ;
Bonvento, G .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (11) :1191-1201
[8]   Kinetic modeling of [C-11]raclopride: Combined PET-microdialysis studies [J].
Endres, CJ ;
Kolachana, BS ;
Saunders, RC ;
Su, T ;
Weinberger, D ;
Breier, A ;
Eckelman, WC ;
Carson, RE .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (09) :932-942
[9]   Image noise properties of a phosphor-coated CCD X-ray detector [J].
Gambaccini, M ;
Taibi, A ;
Baldelli, P ;
Del Guerra, A ;
Tuffanelli, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :508-510
[10]  
Garlick PB, 1997, NMR BIOMED, V10, P138, DOI 10.1002/(SICI)1099-1492(199705)10:3<138::AID-NBM474>3.0.CO