Tailored Side-Chain Architecture of Benzil Voltage Stabilizers for Enhanced Dielectric Strength of Cross-Linked Polyethylene

被引:64
作者
Jarvid, Markus [1 ]
Johansson, Anette [2 ]
Bjuggren, Jonas M. [1 ]
Wutzel, Harald [1 ]
Englund, Villgot [3 ]
Gubanski, Stanislaw [2 ]
Muller, Christian [1 ]
Andersson, Mats R. [1 ,4 ]
机构
[1] Chalmers Univ Technol, Dept Chem & Biol Engn Polymer Technol, S-51296 Gothenburg, Sweden
[2] Chalmers Univ Technol, Dept Mat & Mfg Technol High Voltage Engn, S-51296 Gothenburg, Sweden
[3] Borealis AB, Innovat & Technol, S-44486 Stenungsund, Sweden
[4] Univ S Australia, Ian Wark Res Inst, Mawson Lakes, SA 5095, Australia
关键词
additives; electrical treeing; polyethylene (PE); stabilization; voltage stabilizer; BREAKDOWN STRENGTH;
D O I
10.1002/polb.23523
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The synthesis and physico-chemical properties of seven benzil-type voltage stabilizers are reported. The benzil core is substituted with alkyl chains of different length that are linked to the benzil core via an ester, ether, or tertiary amine group. All additives can be melt-processed with low-density polyethylene (LDPE). Fourier-transform infrared spectroscopy confirms that benzil compounds are not affected by the LDPE cross-linking reaction induced by dicumyl peroxide. Moreover, a combination of gel content measurements, thermal analysis, and small-angle X-ray scattering indicates that the presence of benzil voltage stabilizers does not significantly alter the microstructure of cross-linked polyethylene (XLPE). Electrical tree inhibition experiments under high-voltage alternating current conditions show that all investigated additives substantially enhance the dielectric strength of the insulating material at a concentration of only 10 mmol kg(-1). The highest improvement in dielectric strength, of more than 70% with respect to reference XLPE, is obtained with voltage stabilizers, which carry short (methyl) side chains that are linked to the benzil core via an ester or tertiary amine group. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1047 / 1054
页数:8
相关论文
共 29 条
[1]  
Amyot N., 2000, ANN REP C ELECT INSU, V2, P743
[2]   Crosslinking of bimodal polyethylene [J].
Andersson, LHU ;
Gustafsson, B ;
Hjertberg, T .
POLYMER, 2004, 45 (08) :2577-2585
[3]   The role of degassing in XLPE power cable manufacture [J].
Andrews, T. ;
Hampton, R. N. ;
Smedberg, A. ;
Wald, D. ;
Waschk, V. ;
Weissenberg, W. .
IEEE ELECTRICAL INSULATION MAGAZINE, 2006, 22 (06) :5-16
[4]  
[Anonymous], 9302004 IEEE
[5]  
[Anonymous], 2011, 620672011 IEC
[6]  
[Anonymous], 2007, STAND TEST METH EV R
[7]  
Antoniello V. D., 2011, P 47 MINN POW SYST C
[8]  
Ashcraft A. C., 1976, P IEEE INT S EL INS, P213
[9]  
Bamji S. S., U.S. Patent, Patent No. [112, 079, 112079]
[10]   Electrical stress enhancement of contaminants in XLPE insulation used for power cables [J].
Bostrom, JO ;
Marsden, E ;
Hampton, RN ;
Nilsson, U ;
Lennartsson, H .
IEEE ELECTRICAL INSULATION MAGAZINE, 2003, 19 (04) :6-12