Panoramic Ultrasound Examination of Posterior Neck Extensors in Healthy Subjects: Intra-Examiner Reliability Study

被引:13
作者
Valera-Calero, Juan Antonio [1 ,2 ]
Gallego-Sendarrubias, Gracia Maria [1 ]
Fernandez-de-las-Penas, Cesar [3 ,4 ]
Cleland, Joshua A. [5 ]
Ortega-Santiago, Ricardo [3 ,4 ]
Arias-Buria, Jose Luis [3 ,4 ]
机构
[1] Univ Camilo Jose Cela, Dept Phys Therapy, Madrid 28692, Spain
[2] Univ Rey Juan Carlos, Escuela Int Doctorado, Alcorcon 28933, Spain
[3] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys, Alcorcon 28922, Spain
[4] Univ Rey Juan Carlos, Catedra Inst Docencia, Clin Invest Fisioterapia Terapia Manual Punc Seca, Madrid 28922, Spain
[5] Tufts Univ, Sch Med, Dept Publ Hlth & Community Med, Phys Therapy Program, Boston, MA 02155 USA
关键词
ultrasonography; panoramic ultrasound; neck muscles; reproducibility of results; MUSCLE SIZE; ULTRASONOGRAPHY; QUALITY;
D O I
10.3390/diagnostics10100740
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies analyzing morphometry of posterior cervical muscles with ultrasound (US) imaging have mainly used Brightness mode (B-mode). Our aim was to investigate the intra-examiner reliability of panoramic US imaging for assessing posterior-lateral cervical muscle layers. Panoramic US images of the neck at C4/C5 level were acquired in 25 asymptomatic subjects (40% women; mean age: 24 years) by an experienced assessor. The cross-sectional area (CSA) of the upper trapezius, splenius, semispinalis, multifidi, rotators, and levator scapulae was measured from panoramic US scans on two separate days. Intra-class correlation coefficients (ICC3,1), standard error of measurement (SEM), minimal detectable change (MDC) and mean, absolute and percent errors were calculated. In general, intra-examiner reliability was excellent with ICC3,1 ranging from 0.978 (trapezius) to 0.993 (semispinalis). The SEM ranged from 0.02 (multifidus) to 0.07 (semispinalis/levator), whereas the MDC ranged from 0.05 (cervical multifidus) to 0.19 (levator/semispinalis). Absolute error was lower than 0.11 cm(2) (levator/semispinalis). No differences between males and females were found. This study found that intra-examiner/rater reliability of panoramic US imaging was excellent for assessing the CSA of the posterior-lateral neck extensor muscles in asymptomatic subjects. The current findings suggest that panoramic US may be a reliable technique for examining the size of the cervical extensor muscles in both males and females.
引用
收藏
页数:7
相关论文
共 18 条
[1]   Panoramic ultrasonography is a valid method to measure changes in skeletal muscle cross-sectional area [J].
Ahtiainen, Juha P. ;
Hoffren, Merja ;
Hulmi, Juha J. ;
Pietikainen, Mikko ;
Mero, Antti A. ;
Avela, Janne ;
Hakkinen, Keijo .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) :273-279
[2]   NORMAL VALUES FOR QUANTITATIVE MUSCLE ULTRASONOGRAPHY IN ADULTS [J].
Arts, Ilse M. P. ;
Pillen, Sigrid ;
Schelhaas, H. Jurgen ;
Overeem, Sebastiaan ;
Zwarts, Machiel J. .
MUSCLE & NERVE, 2010, 41 (01) :32-41
[3]   Does muscle morphology change in chronic neck pain patients? - A systematic review [J].
De Pauw, R. ;
Coppieters, I. ;
Kregel, J. ;
De Meulemeester, K. ;
Danneels, L. ;
Cagnie, B. .
MANUAL THERAPY, 2016, 22 :42-49
[4]   Cross-sectional area of cervical multifidus muscle in females with chronic bilateral neck pain compared to controls [J].
Fernandez-De-Las-Penas, Cesar ;
Albert-Sanchis, Joan C. ;
Buil, Miguel ;
Benitez, Jose C. ;
Alburquerque-Sendin, Francisco .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (04) :175-180
[5]   Head and neck fascia and compartments: No space for spaces [J].
Guidera, Alice K. ;
Dawes, Patrick J. D. ;
Fong, Amy ;
Stringer, Mark D. .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (07) :1058-1068
[6]   ULTRASONOGRAPHY OF THE CERVICAL MUSCLES: A CRITICAL REVIEW OF THE LITERATURE [J].
Javanshir, Khodabakhsh ;
Amiri, Mohsen ;
Mohseni-Bandpei, Mohammad Ali ;
Rezasoltani, Asghar ;
Fernandez-de-las-Penas, Cesar .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2010, 33 (08) :630-637
[7]   TEST-RETEST RELIABILITY OF SINGLE TRANSVERSE VERSUS PANORAMIC ULTRASOUND IMAGING FOR MUSCLE SIZE AND ECHO INTENSITY OF THE BICEPS BRACHII [J].
Jenkins, Nathaniel D. M. ;
Miller, Jessie M. ;
Buckner, Samuel L. ;
Cochrane, Kristen C. ;
Bergstrom, Haley C. ;
Hill, Ethan C. ;
Smith, Cory M. ;
Housh, Terry J. ;
Cramer, Joel T. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (06) :1584-1591
[8]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[9]   Reliability of ultrasonography for the cervical multifidus muscle in asymptomatic and symptomatic subjects [J].
Kristjansson, E .
MANUAL THERAPY, 2004, 9 (02) :83-88
[10]  
Kumar S, 2010, P 2 NAT C SIGN IM PR