Improved scanning range for coherent anti-Stokes Raman spectroscopy using a tunable optical parametric oscillator

被引:9
作者
Chen, PC
机构
[1] Department of Chemistry, Spelman College, Box 307, Atlanta, GA 30314
关键词
D O I
10.1021/ac960073u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coherent anti-Stokes Raman spectroscopy (CARS) is a well-known form of nonlinear spectroscopy that has been used for a wide range of specialized quantitative applications. From an analytical chemist's point of view, however, conventional CARS is impractical as a tool for qualitative and quantitative analyses because the scan range is too short to produce complete vibrational spectra. This paper introduces a new technique, synchronously scanned optical parametric oscillator (OPO) CARS, that improves the potential for using nonlinear spectroscopy as an analytical technique in both gas- and condensed-phase samples. First, it uses a broadly tunable OPO to increase the scan range. Second, phase matching problems that limit scans in condensed-phase CARS are reduced by using both the signal and the idler beams in a synchronous scanning manner. Finally, this synchronous scanning method generates an output signal that remains fixed at a single wavelength (single-wavelength detection). Advantages of single-wavelength detection include reduction of stray light, simplicity, and elimination of the need for wavelength calibration of the detection optics. Results are presented on neat and mixed samples in gas and condensed phases.
引用
收藏
页码:3068 / 3071
页数:4
相关论文
共 34 条
[1]   MEASUREMENT METHOD OF NONRESONANT 3RD-ORDER SUSCEPTIBILITY BY USING OFF-RESONANT COHERENT ANTI-STOKES-RAMAN SPECTROSCOPY [J].
AKIHAMA, K ;
ASAI, T ;
YAMAZAKI, S .
APPLIED OPTICS, 1993, 32 (36) :7434-7441
[2]   COMPARISON OF GROUND-STATE AND EXCITED-STATE RAMAN TRANSITIONS USING RESONANT COHERENT STOKES GENERATION [J].
ANDREWS, JR ;
HOCHSTRASSER, RM .
CHEMICAL PHYSICS LETTERS, 1981, 83 (03) :427-431
[3]   TEST OF AN OPTICAL PARAMETRIC OSCILLATOR (OPO) AS A COMPACT AND FAST TUNABLE STOKES SOURCE IN COHERENT ANTI-STOKES-RAMAN SPECTROSCOPY (CARS) [J].
BRUGGEMANN, D ;
HERTZBERG, J ;
WIES, B ;
WASCHKE, Y ;
NOLL, R ;
KNOCHE, KF ;
HERZIGER, G .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1992, 55 (04) :378-380
[4]  
Byer R. L., 1977, Nonlinear infrared generation, P81
[5]   ANALYSIS OF VIBRONIC MODE-COUPLING IN PENTACENE BY FULLY RESONANT COHERENT 4-WAVE MIXING [J].
CARLSON, RJ ;
NGUYEN, DC ;
WRIGHT, JC .
JOURNAL OF CHEMICAL PHYSICS, 1990, 92 (03) :1538-1546
[6]   ANALYSIS OF VIBRATIONAL CORRELATIONS AND COUPLINGS IN THE LOWEST 2 SINGLET-STATES OF PENTACENE BY HIGH-RESOLUTION, FULLY RESONANT, COHERENT 4-WAVE MIXING SPECTROSCOPY [J].
CARLSON, RJ ;
WRIGHT, JC .
JOURNAL OF CHEMICAL PHYSICS, 1990, 92 (09) :5186-5195
[7]  
CARREIRA LA, 1982, NONLINEAR RAMAN SPEC, P367
[8]   TEMPERATURE AND CONCENTRATION DISTRIBUTION OF H2 AND H-ATOMS IN HOT-FILAMENT CHEMICAL-VAPOR DEPOSITION OF DIAMOND [J].
CHEN, KH ;
CHUANG, MC ;
PENNEY, CM ;
BANHOLZER, WF .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (03) :1485-1493
[9]  
CHEN PC, 1992, THESIS U WISCONSIN M, P59
[10]  
Clark R J H, 1988, ADV SPECTROSCOPY, V15