Performance Assessment of Smart Meter Traffic over LTE Network Using SDR Testbed

被引:0
|
作者
Hematian, Amirshahram [1 ]
Yu, Wei [1 ]
Griffith, David [2 ]
Golmie, Nada [2 ]
机构
[1] Towson Univ, Towson, MD 21252 USA
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
2019 INTERNATIONAL CONFERENCE ON COMPUTING, NETWORKING AND COMMUNICATIONS (ICNC) | 2019年
关键词
Smart Grid Communications; Software Defined Radio; Performance Assessment; Hardware-In-The-Loop; Wireless Networks; COMMUNICATION; INTERNET; SCHEME;
D O I
10.1109/iccnc.2019.8685535
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In the smart grid, a variety of smart meters will be deployed to support diverse services, such as energy distribution management, grid monitoring and management, and the integration of renewable energy resources. On the power distribution side, regular Smart Meters (SMs) generale low-rate data traffic for system maintenance, billing, and more. In contrast, on the transmission side, a number of enhanced Smart Meters (eSMs), including Phasor Measurement Units (PMUs), among others, are deployed and can generate much higher data rates. Naturally, monitoring the grid becomes much easier for utility providers using real-time information provided by eSMs for timely control of the grid. Nonetheless, how to deliver such large data volumes with high data rates generated by eSMs is a significant challenge. To address this issue, in this paper, we consider the transmission of eSM data over Long-Term Evolution (LTE) network as a potential solution and assess its viability through practical evaluation. Specifically, we design a Software Defined Radio (SDR) testbed that uses the srsLTE library to create an LTE network and conduct Hardware-In-theLoop (HIL) simulation to assess the effectiveness of transmitting the eSM data over LTE. In our experiments, we simulate data traffic from eSMs based on the IEEE C37.118.2 standard for streaming protocol and packet structure, as well as the IEC 61850 standard for data transmission rate and error rate. Our investigation demonstrates how sporadic eSM data traffic in a neighborhood area network (NAN) can challenge a real-world LTE network system, and additionally shows the effectiveness of transmission scheduling of eSM data traffic locally within the NAN.
引用
收藏
页码:408 / 412
页数:5
相关论文
共 30 条
  • [21] Towards Smart Integration of Distributed Energy Resources Using Distributed Network Protocol Over Ethernet
    Padilla, Esteban
    Agbossou, Kodjo
    Cardenas, Alben
    IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (04) : 1686 - 1695
  • [22] SDN-Enabled FiWi-IoT Smart Environment Network Traffic Classification Using Supervised ML Models
    Ganesan, Elaiyasuriyan
    Hwang, I-Shyan
    Liem, Andrew Tanny
    Ab-Rahman, Mohammad Syuhaimi
    PHOTONICS, 2021, 8 (06)
  • [23] Performance assessment of electric power generations using an adaptive neural network algorithm
    Azadeh, A.
    Ghaderi, S. F.
    Anvari, M.
    Saberi, M.
    ENERGY POLICY, 2007, 35 (06) : 3155 - 3166
  • [24] PERFORMANCE ASSESSMENT OF SAFETY BARRIERS IN LIQUID HYDROGEN BUNKERING OPERATIONS USING BAYESIAN NETWORK
    Tamburini, Federica
    Ustolin, Federico
    Cozzani, Valerio
    Paltrinieri, Nicola
    PROCEEDINGS OF ASME 2024 43RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, OMAE2024, VOL 2, 2024,
  • [25] Smart cities dynamic performance assessment in China using vertical and horizontal deviation maximization method and driving indicator analysis
    Wang, Lu
    Yi, Pingtao
    Li, Weiwei
    Dong, Qiankun
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2024, 26 (05) : 11847 - 11880
  • [26] Smart cities dynamic performance assessment in China using vertical and horizontal deviation maximization method and driving indicator analysis
    Wang, Lu
    Yi, Pingtao
    Li, Weiwei
    Dong, Qiankun
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2023, 26 (5) : 11847 - 11880
  • [27] Smart cities dynamic performance assessment in China using vertical and horizontal deviation maximization method and driving indicator analysis
    Lu Wang
    Pingtao Yi
    Weiwei Li
    Qiankun Dong
    Environment, Development and Sustainability, 2024, 26 : 11847 - 11880
  • [28] Initial Over-the-Air Performance Assessment of Ranging and Clock Synchronization Using Radio Frequency Signal Exchange
    Bidigare, Patrick
    Pruessing, Scott
    Raeman, David
    Scherber, Dzul
    Madhow, Upamanyu
    Mudumbai, Raghu
    2012 IEEE STATISTICAL SIGNAL PROCESSING WORKSHOP (SSP), 2012, : 273 - 276
  • [29] Performance assessment of decision-making units using an adaptive neural network algorithm: one period case
    Mona Anvari
    Mohammad Saidi Mehrabad
    Ali Azadeh
    Morteza Saberi
    The International Journal of Advanced Manufacturing Technology, 2010, 46 : 1059 - 1069
  • [30] Performance assessment of decision-making units using an adaptive neural network algorithm: one period case
    Anvari, Mona
    Mehrabad, Mohammad Saidi
    Azadeh, Ali
    Saberi, Morteza
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2010, 46 (9-12) : 1059 - 1069