Influence of reduced VAV flow settings on indoor thermal comfort in an office space

被引:18
作者
Gangisetti, Kavita [1 ]
Claridge, David E. [1 ]
Srebric, Jelena [2 ]
Paulus, Mitchell T. [1 ]
机构
[1] Texas A&M Univ, College Stn, TX 77845 USA
[2] Univ Maryland, College Pk, MD 20742 USA
关键词
CFD; thermal comfort; draught; diffusers; turbulence; NUMERICAL-MODELS; AIR MOVEMENT; BUILDINGS; ROOM; OPENINGS; DRAFT;
D O I
10.1007/s12273-015-0254-3
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air temperature distribution in a space with reduced diffuser flow rates and heat loads was studied using simulation. Computational fluid dynamics (CFD) was used to analyze the room air distribution from a side wall diffuser at the design flow rate, and the results were validated with experimental data. CFD was used to predict occupant discomfort under a range of reduced diffuser flow rates. It was found for diffuser flow rates above 30% of the design flow rate that the temperature influence from the jet was minimal. At these flow rates, there was nearly a uniform temperature distribution in the occupied zone. The predicted maximum value of percentage of dissatisfied occupants within the space began to increase for diffuser flow rates below 30% of the design flow rate. The percent dissatisfaction at 1 m room height was greater than 25% for the lowest diffuser flow rate tested (15% of the design flow rate) directly under the diffuser, which was the highest of the test cases, but was 5% or less throughout more than 90% of the room. In contrast, at the higher flow rates, the percent dissatisfied index was 5% or less in only 60%-80% of the room due to increased velocity. Evidence of dumping was already found at the traditional minimum flow rate setting of 30% of design, and so there would be little harm in reducing the minimum flow rate further. Reducing the flow rate below 30% of design just moved the location of the dumping closer to the diffuser. For very low diffuser flow rates (below 30% of the design flow rate), it is recommended that desks be placed away from the supply diffuser to avoid discomfort. Overall, the simulation results indicate that uniform temperatures are maintained in the room at flow rates as low as 15% of design except immediately under the diffuser. This suggests that the VAV minimum flow rates can be set below 30% of design flow as long as the diffuser is at least 1 m from an occupant's position.
引用
收藏
页码:101 / 111
页数:11
相关论文
共 42 条
[21]  
Huo Y, 1996, P INT C AIR DISTR RO, P233
[22]  
Kajiya R, 2011, P 12 INT IBPSA BUILD, P1670
[23]   Cooling effects of preferred air velocity in muggy conditions [J].
Kubo, H ;
Isoda, N ;
EnomotoKoshimizu, H .
BUILDING AND ENVIRONMENT, 1997, 32 (03) :211-218
[24]   Thermal comfort assessment and potential for energy efficiency enhancement in modern tropical buildings: A review [J].
Kwong, Qi Jie ;
Adam, Nor Mariah ;
Sahari, B. B. .
ENERGY AND BUILDINGS, 2014, 68 :547-557
[25]  
Lemaire A.D., 1993, Room Air and Contaminant Flow, Evaluation of Computational Methods Subtask-1 Summary Report
[26]   Simulation of air flow in the IEA Annex 20 test room - validation of a simplified model for the nozzle diffuser in isothermal test cases [J].
Luo, S ;
Heikkinen, J ;
Roux, B .
BUILDING AND ENVIRONMENT, 2004, 39 (12) :1403-1415
[27]   Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study [J].
Mendell, M. J. ;
Mirer, A. G. .
INDOOR AIR, 2009, 19 (04) :291-302
[28]  
Nielsen P, 1989, REPRESENTATION BOUND
[29]  
NIELSEN PV, 1992, ASHRAE TRAN, V98, P963
[30]   Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system [J].
Noh, Kwang-Chul ;
Jang, Jae-Soo ;
Oh, Myung-Do .
BUILDING AND ENVIRONMENT, 2007, 42 (02) :689-698