Post-column addition as a method of controlling triacylglycerol response coefficient of an evaporative light scattering detector in liquid chromatography-evaporative light-scattering detection

被引:29
作者
Héron, S
Dreux, M
Tchapla, A
机构
[1] Univ Paris 11, Grp Chim Analyt, IUT Orsay, LETIAM, F-91400 Orsay, France
[2] Sedere, F-91140 Alfortville, France
关键词
evaporative light-scattering detection; detection; LC; triacylglycerols;
D O I
10.1016/j.chroma.2004.02.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The non-linear response is generally the main limitation to the general quantitative use of evaporative light-scattering detection (ELSD). In the particular case of triacylglycerol (TG) analysis, we present a preliminary paper dealing with the use of post-column additives as a means of monitoring the response of such a detector. As TG can form molecular association complexes (ligand-ligate associations) with either cholesterol, urea or silver nitrate, we report the influence of the concentration of each of these chemical compounds in the liquid phase directed towards the ELSD system. The results show that the response coefficient b of the calibration curve either decreases from 1.25-1.30 to 0.51 or increases from 1.25-1.30 to 1.78 according to the nature and concentration of post-column additive. The use of cholesterol as additive, at a discrete concentration, may lead to a linear response curve (b = 1), i.e. to the direct proportionality of ELSD response versus the TG concentration, making quantitative analysis of such solutes easier. On the other hand, to improve sensitivity, the addition of silver nitrate may be chosen for an increase in b value. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 36 条
[1]  
Alexander JN, 1998, J MICROCOLUMN SEP, V10, P491, DOI 10.1002/(SICI)1520-667X(1998)10:6<491::AID-MCS4>3.0.CO
[2]  
2-B
[3]  
Andersson MBO, 1998, J MICROCOLUMN SEP, V10, P249, DOI 10.1002/(SICI)1520-667X(1998)10:3<249::AID-MCS2>3.3.CO
[4]  
2-J
[5]   Authentication of vegetable oils by chromatographic techniques [J].
Aparicio, R ;
Aparicio-Ruíz, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 881 (1-2) :93-104
[6]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[7]   Mechanism of response enhancement in evaporative light scattering detection with the addition of triethylamine and formic acid [J].
Deschamps, FS ;
Baillet, A ;
Chaminade, P .
ANALYST, 2002, 127 (01) :35-41
[8]   Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species [J].
Deschamps, FS ;
Gaudin, K ;
Lesellier, E ;
Tchapla, A ;
Ferrier, D ;
Baillet, A ;
Chaminade, P .
CHROMATOGRAPHIA, 2001, 54 (9-10) :607-611
[9]  
Dreux M., 1996, LC GC INTERNATIONAL, V9, P148
[10]   Determination of inorganic anions on porous graphitic carbon using evaporative light scattering detection - Use of carboxylic acids as electronic competitors [J].
Elfakir, C ;
Chaimbault, P ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) :193-199