Morselized bone autograft for high placement of acetabular component closure with hip arthroplasty revision after 3-years screws and cup loosening: A case report

被引:0
作者
Bari, Yunus Abdul [1 ,3 ]
Chilmi, Mohammad Zaim [2 ]
Arianto, Huda Fajar [1 ]
Soetojo, Bagus Wibowo [2 ]
机构
[1] Univ Airlangga Teaching Hosp, Dept Orthoped & Traumatol, Surabaya, East Java, Indonesia
[2] Dr Soetomo Gen Hosp, Dept Orthoped & Traumatol, Surabaya, East Java, Indonesia
[3] Univ Airlangga Teaching Hosp, Dept Orthoped, Jalan Dharmahusada Permai, Surabaya 60155, East Java, Indonesia
来源
INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS | 2022年 / 101卷
关键词
High placement acetabular; Total hip arthroplasty revision; Morselized bone autograft; Case report; FOLLOW-UP; REPLACEMENT; MINIMUM; THA;
D O I
10.1016/j.ijscr.2022.107789
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction and importance: Aseptic loosening in high placement of the acetabular component seriously affects the hip and femoral head loads. Surgery revision is highly recommended with defect closure in previous place. Case presentation: A-40-year-old man came with chief complaint of right groin pain and noticeable leg length discrepancy gait. The first hip arthroplasty through pseudo-acetabulum cup was done three years ago after neglected femoral head necrosis due to eight years of unknown hip dislocation in vehicle accident. On hip x-ray there is a screws and cup loosening, without any sign of infection from blood or from soft tissue which undergoes pathological and mold examination. The patient than assessed with periprosthetic aseptic loosening of hip dextra and simple total hip arthroplasty revision using true acetabulum location was done. The pseudo-acetabulum area closed with morselized bone autograft. One weeks after surgery, the wound healed properly. Hence, the patient sent to the rehabilitation. Clinical discussion: Hip arthroplasty revision of aseptic loosening in high placement acetabular component should perform by returning to anatomical acetabular position. Cancellous morselized bone autograft (MBA) was used to closed the defect formed by previous procedure. Conclusion: Revision of hip arthroplasty combined with morselized bone autograft can be considered for high placement acetabular component defect closure to provide better stability and strength in weight loads transfer.
引用
收藏
页数:4
相关论文
共 3 条
  • [1] New acetabulum bone formation after 10-years impaction bone graft and cemented acetabular cup lead to simple revision-THA with cementless acetabular cup: A case report
    Rahmansyah, Nur
    Santoso, Asep
    Anwar, Iwan Budiwan
    Sibarani, Tangkas S. M. H. S.
    Mariyanto, Ismail
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2022, 95
  • [2] Custom-made 3D-printed porous metal acetabular composite component in revision hip arthroplasty with Paprosky type III acetabular defects: A case report
    Xiao, Cong
    Zhang, Shaoyun
    Gao, Zhixiang
    Tu, Chongqi
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 283 - 291
  • [3] High Risk of Revision Associated with the L-Cup Titanium Alloy Porous Coated Acetabular Component in Primary Total Hip Arthroplasty: Minimum Follow-Up of 14 Years
    Drobniewski, Marek
    Ruzik, Kacper
    Gonera, Bartosz
    Olewnik, Lukasz
    Borowski, Adam
    Triantafyllou, George
    Borowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)