Voltammetric studies on the electrochemical determination of methylmercury in chloride medium at carbon microelectrodes

被引:21
|
作者
Ribeiro, F.
Neto, M. M. M.
Rocha, M. M.
Fonseca, I. T. E.
机构
[1] Univ Lisbon, Ctr Electroquim & Cinet, Dept Quim & Bioquim, Fac Ciencias, P-1749016 Lisbon, Portugal
[2] Inst Super Agron, Dept Quim Agr & Ambiental, P-1349017 Lisbon, Portugal
关键词
methylmercury determination; carbon microelectrodes; square wave voltammetry; fast-scan linear-sweep voltammetry; water analysis;
D O I
10.1016/j.aca.2006.07.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electroanalytical techniques have been used to determine methylmercury at low levels in environmental matrices. The electrochemical behaviour of methylmercury at carbon microelectrodes in a hydrochloric acid medium using cyclic, square wave and fast-scan linear-sweep voltammetric techniques has been investigated. The analytical utility of the methylmercury reoxidation peak has been explored, but the recorded peak currents were found to be poorly reproducible. This is ascribed to two factors: the adsorption of insoluble chloromercury compounds on the electrode surface, which appears to be an important contribution to hinder the voltammetric signal of methylmercury; and the competition between the reoxidation of the methylmercury radical and its dimerization reaction, which limits the reproducibility of the methylmercury peak. These problems were successfully overcome by adopting the appropriate experimental conditions. Fast-scan rates were employed and an efficient electrochemical regeneration procedure of the electrode surface was achieved, under potentiostatic conditions in a mercury-free solution containing potassium thiocyanate-a strong complexing agent. The influence of chloride ion concentration was analysed. Interference by metals, such as lead and cadmium, was considered. Calibration plots were obtained in the micromolar and submicromolar concentration ranges, allowing the electrochemical determination of methylmercury in trace amounts. An estuarine water sample was analysed using the new method with a glassy carbon microelectrode. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
  • [21] Electrochemical analysis of carbon interdigitated microelectrodes
    Kostecki, R
    Song, X
    Kinoshita, K
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (09) : 465 - 467
  • [22] Electrochemical Behavior and Voltammetric Determination of Albendazole Using Carbon Paste Electrode
    Mersal, Gaber A. M.
    Alharthi, Salman S.
    Al Maliki, Nouf A. S.
    Zayed, Sayed I. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (06): : 1 - 14
  • [24] Voltammetric determination of nitric oxide on cobalt phthalocyanine modified microelectrodes
    Vilakazi, SL
    Nyokong, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 512 (1-2): : 56 - 63
  • [25] ANALYTICAL APPLICATIONS OF CYLINDRICAL CARBON-FIBER MICROELECTRODES - SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANTS IN FOOD
    AGUI, ML
    REVIEJO, AJ
    YANEZSEDENO, P
    PINGARRON, JM
    ANALYTICAL CHEMISTRY, 1995, 67 (13) : 2195 - 2200
  • [26] Voltammetric behaviour of indole at carbon fibre microelectrodes in organic solvents:: Application to the determination of indole in food samples
    Gómez-Gil, C
    González-Cortés, A
    Agüí, L
    Yáñez-Sedeño, P
    Pingarrón, JM
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2003, 42 (04): : 727 - 732
  • [27] DIDENT CARBON-FIBER MICROELECTRODES FOR ELECTRO-PHYSIOLOGICAL AND ELECTROCHEMICAL STUDIES
    ARMSTRONGJAMES, M
    FOX, K
    KRUK, ZL
    MILLAR, J
    BRITISH JOURNAL OF PHARMACOLOGY, 1981, 72 (03) : P507 - P507
  • [28] AC VOLTAMMETRIC AND IMPEDANCE STUDIES OF THE ELECTROCHEMICAL OXIDATION OF PYRROLE IN AQUEOUS-MEDIUM
    SHIU, KK
    ZHANG, YZ
    WONG, KY
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 389 (1-2): : 105 - 114
  • [29] Multiwall carbon nanotube-modified electrode as a nanosensor for electrochemical studies and stripping voltammetric determination of an antimalarial drug
    Ghoreishi, Sayed Mehdi
    Attaran, Abdol Mohammad
    Amin, Atiyeh Moqadam
    Khoobi, Asma
    RSC ADVANCES, 2015, 5 (19): : 14407 - 14415
  • [30] RADIOCHEMICAL DETERMINATION OF METHYLMERCURY CHLORIDE .1. ISOTOPE EXCHANGE IN SULFURIC-ACID MEDIUM
    STARY, J
    PRASILOVA, J
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1976, 26 (03): : 193 - 198