Reliability of an ultrasonographical scoring system for diagnosis of sinusoidal obstruction syndrome/veno-occlusive disease in patients with hematopoietic stem cell transplantation

被引:4
作者
Iwai, Takahito [1 ,2 ]
Nishida, Mutsumi [1 ,2 ]
Sugita, Junichi [1 ,3 ]
Kudo, Yusuke [1 ,2 ]
Takasugi, Rika [2 ]
Yokota, Isao [4 ]
Takagi, Ryo [5 ]
Shibuya, Hitoshi [2 ]
Takahashi, Shuichiro [1 ,3 ]
Teshima, Takanori [1 ,3 ]
机构
[1] Hokkaido Univ Hosp, Div Lab & Transfus Med, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ Hosp, Diagnost Ctr Sonog, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ Hosp, Dept Hematol, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Biostat, Sapporo, Hokkaido, Japan
[5] Hokkaido Univ, Biostat Div, Hosp Clin Res & Med Innovat Ctr, Sapporo, Hokkaido, Japan
关键词
Sinusoidal obstruction syndrome; Hepatic veno-occlusive disease; Hematopoietic stem cell transplantation; Operator reliability; Ultrasonography; HEPATIC VENOOCCLUSIVE DISEASE; BONE-MARROW TRANSPLANTATION; CHILDREN; CLASSIFICATION; ULTRASOUND; CRITERIA; BLOOD; LIVER;
D O I
10.1007/s10396-020-01071-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Sinusoidal obstruction syndrome (SOS)/hepatic veno-occlusive disease (VOD) is a fatal complication after hematopoietic stem cell transplantation. We previously reported the usefulness of an ultrasonographical (US) scoring system, the Hokkaido US-based scoring system consisting of ten parameters (HokUS-10): (1) hepatomegaly in the left lobe and (2) right lobe, (3) dilatation of the main portal vein (PV), (4) hepatofugal flow in the main PV, (5) decreased velocity of the PV, (6) dilatation of the para-umbilical vein (PUV), (7) appearance of blood flow signal in the PUV, (8) gallbladder (GB) wall thickening, (9) ascites, and (10) increased resistive index of the hepatic artery, for the diagnosis of SOS/VOD. However, the reliability of this system among operators remains elusive. Therefore, we prospectively evaluated the reliability of HokUS-10. Methods Twenty-four healthy volunteers and 40 patients with liver dysfunction were enrolled. Inter- and intra-operator reliabilities were analyzed using three sonographers. Results The median concordance rate of HokUS-10 among three sonographers and intra-operator in 24 volunteers was 92% (95% CI: 73-98%) and 98% (95% CI: 92-100%), respectively. In all 64 cases, in terms of the reliability between two sonographers for three representative US parameters (amount of ascites, GB wall thickening, and appearance of PUV blood flow signal), the median concordance rate was more than 98% (95% CI: 86-106%). Conclusion The inter- and intra-reliabilities of HokUS-10 were excellent. Thus, US might be a reliable tool for SOS/VOD diagnosis.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 24 条
  • [1] Diagnosis and Treatment of VOD/SOS After Allogeneic Hematopoietic Stem Cell Transplantation
    Bonifazi, Francesca
    Barbato, Francesco
    Ravaioli, Federico
    Sessa, Mariarosaria
    Defrancesco, Irene
    Arpinati, Mario
    Cavo, Michele
    Colecchia, Antonio
    [J]. FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [2] DOPPLER SONOGRAPHY - A NONINVASIVE METHOD FOR EVALUATION OF HEPATIC VENOOCCLUSIVE DISEASE
    BROWN, BP
    ABUYOUSEF, M
    FARNER, R
    LABRECQUE, D
    GINGRICH, R
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) : 721 - 724
  • [3] Modified diagnostic criteria, grading classification and newly elucidated pathophysiology of hepatic SOS/VOD after haematopoietic cell transplantation
    Cairo, Mitchell S.
    Cooke, Kenneth R.
    Lazarus, Hillard M.
    Chao, Nelson
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2020, 190 (06) : 822 - 836
  • [4] Cheuk Daniel Kl, 2012, World J Transplant, V2, P27, DOI 10.5500/wjt.v2.i2.27
  • [5] Hepatic Veno-Occlusive Disease following Stem Cell Transplantation: Incidence, Clinical Course, and Outcome
    Coppell, Jason A.
    Richardson, Paul G.
    Soiffer, Robert
    Martin, Paul L.
    Kernan, Nancy A.
    Chen, Allen
    Guinan, Eva
    Vogelsang, Georgia
    Krishnan, Amrita
    Giralt, Sergio
    Revta, Carolyn
    Carreau, Nicole A.
    Iacobelli, Massimo
    Carreras, Enric
    Ruutu, Tapani
    Barbui, Tiziano
    Antin, Joseph H.
    Niederwieser, Dietger
    [J]. BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2010, 16 (02) : 157 - 168
  • [6] Incidence of Anicteric Veno-Occlusive Disease/Sinusoidal Obstruction Syndrome and Outcomes with Defibrotide following Hematopoietic Cell Transplantation in Adult and Pediatric Patients
    Corbacioglu, Selim
    Kernan, Nancy A.
    Pagliuca, Antonio
    Ryan, Robert J.
    Tappe, William
    Richardson, Paul G.
    [J]. BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2020, 26 (07) : 1342 - 1349
  • [7] NEW ULTRASOUND TECHNIQUES CHALLENGE THE DIAGNOSIS OF SINUSOIDAL OBSTRUCTION SYNDROME
    Dietrich, Christoph F.
    Trenker, Corinna
    Fontanilla, Teresa
    Gorg, Christian
    Hausmann, Andreas
    Klein, Stefan
    Lassau, Nathalie
    Miquel, Rosa
    Schreiber-Dietrich, Dagmar
    Dong, Yi
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (11) : 2171 - 2182
  • [8] VENOOCCLUSIVE LIVER-DISEASE AFTER BONE-MARROW TRANSPLANTATION - FINDINGS AT DUPLEX SONOGRAPHY
    HERBETKO, J
    GRIGG, AP
    BUCKLEY, AR
    PHILLIPS, GL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) : 1001 - 1005
  • [9] Duplexsonography of the mesenteric vessels - acritical evaluation of inter observer variability
    Ignee, A.
    Boerner, N.
    Bruening, A.
    Dirks, K.
    von Herbay, A.
    Jenssen, C.
    Kubale, R.
    Sattler, H.
    Schuler, A.
    Weiss, H.
    Schuessler, G.
    Dietrich, C. F.
    [J]. ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2016, 54 (04): : 304 - 311
  • [10] Assessment of the proposed EBMT pediatric criteria for diagnosis and severity grading of sinusoidal obstruction syndrome
    Kammersgaard, Marte B.
    Kielsen, Katrine
    Heilmann, Carsten
    Ifversen, Marianne
    Mueller, Klaus
    [J]. BONE MARROW TRANSPLANTATION, 2019, 54 (09) : 1406 - 1418