A liquid chromatography-tandem mass spectrometry method for simultaneous determination of simeprevir, daclatasvir, sofosbuvir, and GS-331007 applied to a retrospective clinical pharmacological study

被引:23
作者
Ferrari, Davide [1 ,2 ]
Bagaglio, Sabrina [3 ]
Raso, Michele [2 ]
Galli, Laura [3 ]
Premaschi, Simone [2 ]
Messina, Emanuela [3 ]
Morsica, Giulia [3 ]
Locatelli, Massimo [2 ]
Uberti-Foppa, Caterina [3 ,4 ]
Hasson, Hamid [3 ]
机构
[1] Univ Parma, SCVSA Dept, Parma, Italy
[2] Osped San Raffaele, Lab Med Serv, Milan, Italy
[3] Osped San Raffaele, Clin Infect Dis, Milan, Italy
[4] Univ Vita Salute San Raffaele, Milan, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2019年 / 1120卷
关键词
HCV; Sofosbuvir; Daclatasvir; Simeprevir; Tandem-mass spectrometry; DAA; HEPATITIS-C VIRUS; HUMAN PLASMA-APPLICATION; MS/MS METHOD; ANTIVIRAL THERAPY; QUANTIFICATION; INHIBITOR; SAFETY; LEDIPASVIR; METABOLITE; INFECTION;
D O I
10.1016/j.jchromb.2019.04.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of daclatasvir (DCV), simeprevir (SMV), sofosbuvir (SOF), and its major metabolite GS-331007 in human plasma using stable-isotope-labeled (SIL) analogs as internal standards (IS) to minimize a possible matrix effect. Liquid-liquid extraction (LLE) of the analytes and IS from human plasma was performed using a commercial extraction kit requiring low sample volume (50 4). The analytes were eluted under a gradient program with mobile phase A (water + 0.1% formic acid) and mobile phase B (methanol + 0.1% formic acid) at a flow-rate of 0.6 mL/min for 10 min. The detection was performed on a Qtrap 5500 triple quadrupole tandem-mass spectrometer using multiple reaction monitoring (MRM) mode via the positive electrospray ionization interface. The method was validated according to the European Medicine Agency (EMA) guidelines over the clinically relevant concentration range of 15.6-2000 ng/mL. The high reproducibility, the low matrix effect associated with the use of SIL-IS, and the need of small sample amounts make this method particularly suited for high-throughput routine analysis. The proposed method was successfully applied to a retrospective clinical pharmacology study involving 67 HIV/HCV co-infected patients treated with a SOF-based therapy. DCV, SMV, SOF, and GS-331007 plasma levels were measured at week 4 of treatment and compared with the patients' clinical and laboratory characteristics. Higher GS-331007 plasma concentrations were observed in female patients compared to males, which can be explained by different anthropometric characteristics between genders. Importantly, patients with high plasma levels of GS-331007 also showed enhanced concentration of DCV and SMV probably due to a specific metabolic/pathological condition. Altogether, our findings indicate that the proposed method is a reliable and accurate new tool for high-throughput screening of large patient cohorts that could be readily used to optimize treatment modalities and reduce drug-related toxicities.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 29 条
[21]   Comparison of different methods aiming to account for/overcome matrix effects in LC/ESI/MS on the example of pesticide analyses [J].
Kruve, Anneli ;
Leito, Ivo .
ANALYTICAL METHODS, 2013, 5 (12) :3035-3044
[22]   Efficacy and safety of 3-week response-guided triple direct-acting antiviral therapy for chronic hepatitis C infection: a phase 2, open-label, proof-of-concept study [J].
Lau, George ;
Benhamou, Yves ;
Chen, Guofeng ;
Li, Jin ;
Shao, Qing ;
Ji, Dong ;
Li, Fan ;
Li, Bing ;
Liu, Jialiang ;
Hou, Jinlin ;
Sun, Jian ;
Wang, Cheng ;
Chen, Jing ;
Wu, Vanessa ;
Wong, April ;
Wong, Chris L. P. ;
Tsang, Stella T. Y. ;
Wang, Yudong ;
Bassit, Leda ;
Tao, Sijia ;
Jiang, Yong ;
Hsiao, Hui-Mien ;
Ke, Ruian ;
Perelson, Alan S. ;
Schinazi, Raymond F. .
LANCET GASTROENTEROLOGY & HEPATOLOGY, 2016, 1 (02) :97-104
[23]   Current and Future Therapies for Hepatitis C Virus Infection [J].
Liang, T. Jake ;
Ghany, Marc G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (20) :1907-1917
[24]   eGFR decrease during antiviral C therapy with first generation protease inhibitors: a clinical significance? [J].
Loustaud-Ratti, Veronique ;
Rousseau, Annick ;
Carrier, Paul ;
Vong, Chanlina ;
Chambaraud, Tristan ;
Jacques, Jeremie ;
Debette-Gratien, Marilyne ;
Sautereau, Denis ;
Essig, Marie .
LIVER INTERNATIONAL, 2015, 35 (01) :71-78
[25]   UPLC-MS/MS method for the simultaneous quantification of sofosbuvir, sofosbuvir metabolite (GS-331007) and daclatasvir in plasma of HIV/HCV co-infected patients [J].
Notari, Stefania ;
Tempestilli, Massimo ;
Fabbri, Gabriele ;
Libertone, Raffaella ;
Antinori, Andrea ;
Ammassari, Adriana ;
Agrati, Chiara .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 :183-190
[26]   Development of a sensitive UPLC-ESI-MS/MS method for quantification of sofosbuvir and its metabolite, GS-331007, in human plasma: Application to a bioequivalence study [J].
Rezk, Mamdouh R. ;
Basalious, Emad B. ;
Karim, Iman A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 :97-104
[27]   Safety and efficacy of sofosbuvir-containing regimens in hepatitis C-infected patients with impaired renal function [J].
Saxena, Varun ;
Koraishy, Farrukh M. ;
Sise, Meghan E. ;
Lim, Joseph K. ;
Schmidt, Monica ;
Chung, Raymond T. ;
Liapakis, Annmarie ;
Nelson, David R. ;
Fried, Michael W. ;
Terrault, Norah A. .
LIVER INTERNATIONAL, 2016, 36 (06) :807-816
[28]   Understanding the hepatitis C virus life cycle paves the way for highly effective therapies [J].
Scheel, Troels K. H. ;
Rice, Charles M. .
NATURE MEDICINE, 2013, 19 (07) :837-849
[29]   Determination of simeprevir: A novel, hepatitis C protease inhibitor in human plasma by high-performance liquid chromatography-tandem mass spectrometry [J].
Vanwelkenhuysen, I. ;
de Vries, R. ;
Timmerman, P. ;
Verhaeghe, T. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 958 :43-47