Coupling of capillary electrophoresis with electrospray ionization multiplexing ion mobility spectrometry

被引:4
作者
Guo, Jianheng [1 ,2 ]
Li, Guozhu [3 ]
Zhang, Hanghang [3 ]
Jia, Xu [3 ]
Meng, Qingyan [3 ]
Liu, Wenjie [1 ,3 ]
机构
[1] Xiangtan Univ, Coll Chem Engn, Xiangtan, Hunan, Peoples R China
[2] Southwest MinZu Univ, Coll Pharm, Chengdu, Sichuan, Peoples R China
[3] Xinjiang Prod & Construct Corps Key Lab Protect &, Alar, Xinjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary electrophoresis; Electrospray ionization; Ion mobility spectrometry;
D O I
10.1002/elps.201800462
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two-dimensional separation. To improve the performance of hyphenated CE-IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 mu L/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5-250 mu g/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 mu g/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE-ESI-IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra-violet transparent compounds or none fluorescent compounds.
引用
收藏
页码:1639 / 1647
页数:9
相关论文
共 50 条
[31]   Coupling High-Field Asymmetric Ion Mobility Spectrometry with Capillary Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry Improves Protein Identifications in Bottom-Up Proteomic Analysis of Low Nanogram Samples [J].
Johnson, Kendall R. ;
Gregus, Michal ;
Ivanov, Alexander R. .
JOURNAL OF PROTEOME RESEARCH, 2022, :2453-2461
[32]   Characterization of metastable intermediates of enzymatic peroxidation of NAD(+) by on-line capillary electrophoresis electrospray ionization mass spectrometry [J].
Zhao, ZX ;
Udseth, HR ;
Smith, RD .
JOURNAL OF MASS SPECTROMETRY, 1996, 31 (02) :193-198
[33]   Analysis of antibiotics from liquid sample using electrospray ionization-ion mobility spectrometry [J].
Li, Shu ;
Jia, Jian ;
Gao, Xiaoguang ;
He, Xiuli ;
Li, Jianping .
ANALYTICA CHIMICA ACTA, 2012, 720 :97-103
[34]   Electrospray ionization ion mobility spectrometry as a field monitoring method for the detection of atrazine in natural water [J].
Wu, C ;
Hill, HH ;
Gamerdinger, AP .
FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1998, 2 (03) :155-161
[35]   A capillary electrophoresis and off-line capillary electrophoresis/electrospray ionization-quadrupole time of flight-tandem mass spectrometry approach for ganglioside analysis [J].
Zamfir, A ;
Vukelic, Z ;
Peter-Katalinic, J .
ELECTROPHORESIS, 2002, 23 (17) :2894-2903
[36]   Detection of Amino Acids and Polypeptides by Electrospray Ionization-Ion Mobility Spectrometry [J].
Kong Jing-Lin ;
Liu Wei-Wei ;
Ding Jun-Jie ;
Zhang Lin ;
Li Bao-Qiang ;
Qin Mo-Lin ;
Chen Chuang ;
Li Hai-Yang .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (11) :1583-1588
[37]   Hair analysis for illicit drugs by using capillary zone electrophoresis-electrospray ionization-ion trap mass spectrometry [J].
Gottardo, Rossella ;
Bortolotti, Federica ;
De Paoli, Giorgia ;
Pascali, Jennifer Paola ;
Miksik, Ivan ;
Tagliaro, Franco .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :185-189
[38]   Determination of yessotoxins and pectenotoxins in shellfish by capillary electrophoresis-electrospray ionization-mass spectrometry [J].
de la Iglesia, P. ;
Gago-Martinez, A. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (02) :221-228
[39]   Analysis of isoflavones in soy drink by capillary zone electrophoresis coupled with electrospray ionization mass spectrometry [J].
Bustamante-Rangel, M. ;
Delgado-Zamarreno, M. M. ;
Carabias-Martinez, R. ;
Dominguez-Alvarez, J. .
ANALYTICA CHIMICA ACTA, 2012, 709 :113-119
[40]   Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins [J].
Haselberg, Rob ;
Ratnayake, Chitra K. ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (48) :7605-7611