Coupling of capillary electrophoresis with electrospray ionization multiplexing ion mobility spectrometry

被引:4
|
作者
Guo, Jianheng [1 ,2 ]
Li, Guozhu [3 ]
Zhang, Hanghang [3 ]
Jia, Xu [3 ]
Meng, Qingyan [3 ]
Liu, Wenjie [1 ,3 ]
机构
[1] Xiangtan Univ, Coll Chem Engn, Xiangtan, Hunan, Peoples R China
[2] Southwest MinZu Univ, Coll Pharm, Chengdu, Sichuan, Peoples R China
[3] Xinjiang Prod & Construct Corps Key Lab Protect &, Alar, Xinjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary electrophoresis; Electrospray ionization; Ion mobility spectrometry;
D O I
10.1002/elps.201800462
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two-dimensional separation. To improve the performance of hyphenated CE-IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 mu L/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5-250 mu g/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 mu g/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE-ESI-IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra-violet transparent compounds or none fluorescent compounds.
引用
收藏
页码:1639 / 1647
页数:9
相关论文
共 50 条
  • [1] Coupling Capillary Electrophoresis and Ion Mobility Spectrometry via electrospray interface: a preliminary study
    Jiang, Xuemei
    Svensmark, Bo
    Deng, Linhong
    MATERIALS SCIENCE AND ENGINEERING APPLICATIONS, PTS 1-3, 2011, 160-162 : 1531 - +
  • [2] Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry
    Tong, Ping
    Zhang, Lan
    He, Yu
    Tang, Shurong
    Cheng, Jintian
    Chen, Guonan
    TALANTA, 2010, 82 (04) : 1101 - 1106
  • [3] High resolution electrospray ionization ion mobility spectrometry
    Krueger, Clinton A.
    Hilton, Christopher K.
    Osgood, Mark
    Wu, Jianglin
    Wu, Ching
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (01) : 33 - 37
  • [4] Subambient pressure electrospray ionization ion mobility spectrometry
    Zühlke M.
    Zenichowski K.
    Riebe D.
    Beitz T.
    Löhmannsröben H.-G.
    Zühlke, M. (mzuehlke@uni-potsdam.de), 1600, Springer Verlag (20): : 47 - 56
  • [5] Thermal effects on electrospray ionization ion mobility spectrometry
    Chen, YH
    Hill, HH
    Wittmer, DP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 154 (1-2): : 1 - 13
  • [6] Compact automated capillary electrophoresis instrument for coupling with mass spectrometry by using sheathless electrospray ionization
    Furter, Jasmine S.
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1656
  • [7] Evaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection
    Matz, LM
    Dion, HM
    Hill, HH
    JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 59 - 68
  • [8] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Zhou, Li
    Collins, David C.
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (01) : 189 - 194
  • [9] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2007, 388 : 189 - 194