Non-enzymatic electrochemical sensor to detect γ-aminobutyric acid with ligand-based on graphene oxide modi fied gold electrode

被引:16
|
作者
Alamry, Khalid A. [1 ]
Hussein, Mahmoud A. [1 ]
Choi, Jeong-woo [2 ]
El-Said, Waleed A. [3 ,4 ]
机构
[1] King Abdulaziz Univ, Dept Chem, Fac Sci, POB 80203, Jeddah 21589, Saudi Arabia
[2] Sogang Univ, Dept Chem & Biomol Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
[3] Univ Jeddah, Dept Chem, Coll Sci, POB 80327, Jeddah 21589, Saudi Arabia
[4] Assiut Univ, Dept Chem, Fac Sci, Assiut 71516, Egypt
关键词
Gamma-aminobutyric acid; Electrochemical sensor; Enzymeless; Glutamate; Cyclic voltammetry; Square wave voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; INDUCED FLUORESCENCE DETECTION; REAL-TIME DETECTION; MICRODIALYSIS SAMPLES; CAPILLARY-ELECTROPHORESIS; SIMULTANEOUS GLUTAMATE; DOPAMINE; BRAIN; GABA; CELL;
D O I
10.1016/j.jelechem.2020.114789
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the simple and sensitive enzymeless electrochemical gamma-aminobutyric acid (GABA) neurotransmitter sensor was developed based on the graphene oxide modified Au electrode with the ligand. A mixture of orthophthalaldehyde (OPA) and an alkylthiol reagent is used as a ligand to interact with GABA, which became an electro-chemical active compound. The sensor consisted of a graphene oxide modified Au electrode. The effect of pH variation on the electrochemical signal of GABA was investigated; a good electrochemical response was observed in neutraland slightly alkalinemedium, i.e. the value of the pH for the physiological-like media. The proposed sensor detected the wide range concentration of GABA from 250 nmol L-1 to 100 mu mol L-1 with a detection limit of 98 nmol L-1. And the sensor could detect a mixture of GABA and Glutamate, and GABA in complex solutions including human serum and urine, which indicated the capability of the sensor to detect GABA in complicated matrixes. The proposed sensor system can be applied to detect neurotransmitters in the brain and be used in the field of diagnosis and treatment of neurological disorders.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Non-enzymatic lactose molecularly imprinted sensor based on disposable graphite paper electrode
    da Silva, Jose Luiz
    Buffon, Edervaldo
    Beluomini, Maisa Azevedo
    Pradela-Filho, Lauro Antonio
    Gouveia Araujo, Diele Aparecida
    Santos, Andre Luiz
    Takeuchi, Rgina Massako
    Stradiotto, Nelson Ramos
    ANALYTICA CHIMICA ACTA, 2021, 1143 : 53 - 64
  • [42] Manganese oxides/carbon nanowall nanocomposite electrode as an efficient non-enzymatic electrochemical sensor for hydrogen peroxide
    Bohlooli, Fatemeh
    Yamatogi, Ayumu
    Mori, Shinsuke
    SENSING AND BIO-SENSING RESEARCH, 2021, 31
  • [43] ZnS and Reduced Graphene Oxide Nanocomposite-Based Non-Enzymatic Biosensor for the Photoelectrochemical Detection of Uric Acid
    Zhao, Yao
    Peng, Niancai
    Gao, Weizhuo
    Hu, Fei
    Zhang, Chuanyu
    Wei, Xueyong
    BIOSENSORS-BASEL, 2024, 14 (10):
  • [44] Flexible cotton-AuNP thread electrode for non-enzymatic sensor of uric acid in urine
    Teekayupak, Kanyapat
    Ruecha, Nipapan
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    CELLULOSE, 2021, 28 (16) : 10501 - 10515
  • [45] Graphene-Oxide-Based Electrochemical Sensor for Salicylic Acid
    Vadivaambigai, A.
    Senthilvasan, Prem Anandh
    Kothurkar, Nikhil
    Rangarajan, Murali
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2015, 7 (02) : 140 - 146
  • [46] An electrochemical ascorbic acid sensor based on palladium nanoparticles supported on graphene oxide
    Wu, Geng-huang
    Wu, Yan-fang
    Liu, Xi-wei
    Rong, Ming-cong
    Chen, Xiao-mei
    Chen, Xi
    ANALYTICA CHIMICA ACTA, 2012, 745 : 33 - 37
  • [47] A Nafion-free non-enzymatic amperometric glucose sensor based on copper oxide nanoparticles-graphene nanocomposite
    Alizadeh, Taher
    Mirzagholipur, Shabnam
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 438 - 447
  • [48] Fabrication of Non-enzymatic Electrochemical Glucose Sensor Based on Nano-copper Oxide Micro Hollow-spheres
    Zahra Haghparas
    Zoheir Kordrostami
    Mohsen Sorouri
    Maryam Rajabzadeh
    Reza Khalifeh
    Biotechnology and Bioprocess Engineering, 2020, 25 : 528 - 535
  • [49] Fabrication of Non-enzymatic Electrochemical Glucose Sensor Based on Nano-copper Oxide Micro Hollow-spheres
    Haghparas, Zahra
    Kordrostami, Zoheir
    Sorouri, Mohsen
    Rajabzadeh, Maryam
    Khalifeh, Reza
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2020, 25 (04) : 528 - 535
  • [50] Development of Non-enzymatic Cholesterol Electrochemical Sensor Based on Polyindole/Tungsten Carbide Nanocomposite
    Shubham Sharma
    Preeti Joshi
    Sameena Mehtab
    Md. Ghulam Haider Zaidi
    Kavita Singhal
    Tanveer Irshad Siddiqi
    Journal of Analysis and Testing, 2020, 4 : 13 - 22