Validation and application of solid-phase chemiluminescent immunoassays for diagnosis of endocrine diseases in animals

被引:70
作者
Reimers, TJ
Salerno, VJ
Lamb, SV
机构
[1] Diagnostic Laboratory, College of Veterinary Medicine, Cornell University, Ithaca, NY
来源
COMPARATIVE HAEMATOLOGY INTERNATIONAL | 1996年 / 6卷 / 03期
关键词
automation; chemiluminescence; endocrinology; immunoassay; validation; veterinary medicine;
D O I
10.1007/BF00368462
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Significant progress has been made in the ability of veterinarians to diagnose endocrine diseases since introduction and development of the radioimmunoassay (RIA) in the 1960s. Alternatives to the radioactive label have been commercialised for human diagnostic applications. Because healthy animals have concentrations of several hormones in serum that are lower than in humans, these non-isotopic assays generally lack the sensitivity for measuring hormones in animals. However, the chemiluminescent enzyme immunoassay may provide this needed sensitivity. We validated the DPC-Cirrus Immulite(R) automated chemiluminescent immunoassay system for measurement of cortisol in dogs, cats and horses. Serial dilutions of serum inhibited binding of alkaline phosphatase-labelled cortisol in a manner that was parallel with inhibition produced by the stored master calibration curve. Six dogs were injected with adrenocorticotropin (ACTH; 2.2 IU/kg i.m.) and five dogs were injected with dexamethasone (0.015 mg/kg i.v.). Changes in cortisol concentrations measured with the Immulite(R) were as expected based on published results. Similar tests of biological specificity in other species yielded similar results. Accuracy of the Immulite(R) cortisol assay was evaluated by comparing cortisol concentrations in serum with concentrations obtained by a validated RIA. The regression equations were: y = 14.6 + 0.8x for dogs (n = 59, r(2) = 0.91), y = 13.5 + 0.9x for horses (n = 23, r(2) = 0.90), and y = 29.8 + 1.Ox for cats (n = 18, r(2) = 0.96), where y = Immulite(R) result (nmol/l) and x = RIA result (nmol/l). The regression equation for the canine urinary cortisol: creatinine ratio was y = 0.43 + 1.55x, where y = ratio calculated from Immulite(R) cortisol concentrations and x = ratio using RIA concentrations (n = 35, r(2) = 0.93). Initially, the lower limit of the reportable range by the Immulite(R) was 27.6 nmol/l, a value that was unacceptable for veterinary diagnostics. After consultation with DPC-Cirrus, we adjusted the lower limit to 1.4 nmol/l. Coefficients of variation for two canine, one feline, and two equine quality-control serum samples included in 73 consecutive Immulite(R) assays ranged from 0.29 (mean = 29.0 nmol/l) to 0.09 (mean = 261.6 nmol/l). We are using the Immulite(R) routinely for the diagnosis of adrenal disease in animals and have found it to provide diagnostically useful cortisol results for dexamethasone-suppression and ACTH-stimulation tests. Its diagnostic accuracy on single baseline samples is probably less than for the RIA, particularly at concentrations of cortisol less than 27.6 nmol/l.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
[41]   HPLC-DAD Development and Validation Method for Short-Chain Fatty Acids Quantification from Chicken Feces by Solid-Phase Extraction [J].
Diaz-Corona, Lenin Rodolfo ;
Parra-Saavedra, Karina Jeanette ;
Mora-Alonzo, Renata Sofia ;
Macias-Rodriguez, Maria Esther ;
Martinez-Preciado, Alma H. ;
Guevara-Martinez, Santiago Jose ;
Zamudio-Ojeda, Adalberto ;
Macias-Lamas, Adriana Macaria .
SEPARATIONS, 2023, 10 (05)
[42]   Validation and application of sub-2 μm core-shell UHPLC-UV-ESI-Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction [J].
Martano, G. ;
Bojaxhi, E. ;
Forstenlehner, I. C. ;
Huber, C. G. ;
Bresgen, N. ;
Eckl, P. M. ;
Stutz, H. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (12) :2909-2924
[43]   APPLICATION OF AMD TO THE DETERMINATION OF CROP-PROTECTION AGENTS IN DRINKING-WATER .3. SOLID-PHASE EXTRACTION AND AFFECTING FACTORS [J].
PFAAB, G ;
JORK, H .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1994, 22 (05) :216-223
[44]   Modified magnetic-based solvent-assisted dispersive solid-phase extraction: application to the determination of cortisol and cortisone in human saliva [J].
Grau, Jose ;
Benede, Juan L. ;
Chisvert, Alberto ;
Salvador, Amparo .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1652
[45]   Use of a presolvent to include volatile organic analytes in the application range of on-line solid-phase extraction gas chromatography mass spectrometry [J].
Hankemeier, T ;
van Leeuwen, SPJ ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 811 (1-2) :117-133
[46]   Development and validation of a bioanalytical method using automated solid-phase extraction and LC-UV for the simultaneous determination of lumefantrine and its desbutyl metabolite in plasma [J].
Lindegårdh, N ;
Annerberg, A ;
Blessborn, D ;
Bergqvist, Y ;
Day, N ;
White, NJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) :1081-1088
[47]   Validation of an on-line solid-phase extraction method coupled to liquid chromatography-tandem mass spectrometry detection for the determination of Indacaterol in human serum [J].
Emotte, Corinne ;
Heudi, Olivier ;
Deglave, Fanny ;
Bonvie, Adrien ;
Masson, Laurence ;
Picard, Franck ;
Chaturvedi, Animesh ;
Majumdar, Tapan ;
Agarwal, Ashish ;
Woessner, Ralph ;
Kretz, Olivier .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 :1-9
[48]   Determination of endocrine-disrupting compounds in water samples by on-line solid-phase extraction-programmed-temperature vaporisation-gas chromatography-mass spectrometry [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2003, 998 (1-2) :41-50
[49]   Automated solid-phase extraction for the determination of polybrominated diphenyl ethers and polychlorinated biphenyls in serum - application on archived Norwegian samples from 1977 to 2003 [J].
Thomsen, Cathrine ;
Liane, Veronica Horpestad ;
Becher, Georg .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2) :252-263
[50]   Preliminary validation of a single-spot version of a solid-phase competition ELISA for the detection of southern African territories foot-and-mouth disease serotype exposure in goats [J].
Gobiye, Moses ;
Fosgate, Geoffrey T. ;
Heath, Livio ;
Lazarus, David D. ;
Seoke, LaToya ;
Opperman, Pamela A. .
SMALL RUMINANT RESEARCH, 2023, 224