A fast, highly selective and sensitive dansyl-based fluorescent sensor for copper (II) ions and its imaging application in living cells

被引:21
|
作者
Zhou, Ming [1 ,2 ]
Wang, Xiaobo [1 ,3 ,4 ]
Huang, Kunzhu [1 ,5 ]
Huang, Yuzhao [2 ]
Hu, Shou [2 ]
Zeng, Wenbin [1 ]
机构
[1] Cent South Univ, Xiangya Sch Pharmaceut Sci, 172 Tongzipo Rd, Changsha 410013, Hunan, Peoples R China
[2] Cent South Univ, Xiangya Hosp, Changsha 410078, Hunan, Peoples R China
[3] Zhengzhou Univ, Henan Prov Peoples Hosp, Dept Nucl Med, Zhengzhou 450003, Henan, Peoples R China
[4] Zhengzhou Univ, Peoples Hosp, Zhengzhou 450003, Henan, Peoples R China
[5] Changsha Med Univ, Sch Pharmaceut Sci, Changsha 410219, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluorescent sensor; Copper (II) ions; Dansyl; ALZHEIMERS; DISEASES; METALS;
D O I
10.1016/j.tetlet.2017.01.090
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Since the copper ions (Cu2+) play a fatal role in many foundational physiological processes, it is important to develop a simple, highly sensitive and selective sensor for Cu2+ detection in living systems. Herein, an intramolecular charge transfer (ICT) and dansyl-based fluorescent chemosensor 1 was designed, synthesized and characterized for the sensitive and selective quantification of Cu2+. It exhibited remarkable fluorescence quenching upon addition of Cu2+ over other selected metal ions, attributed to the complex formation between 1 and Cu2+ with the association constant 6.7 x 10(5) M-1. The sensor 1 showed a fast and linear response towards Cu2+ in the concentration range from 0 to 12.5 x 10(-6) mol L-1 with the detection limit of 2.5 x 10(-7) mol L-1. This detection could be carried out in a wide pH range of 5.0-14. Furthermore, sensor 1 can be used for detecting Cu2+ in living cells. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:991 / 994
页数:4
相关论文
共 50 条
  • [41] Fluorescent probe for copper(II) ion based on a rhodamine spirolactame derivative, and its application to fluorescent imaging in living cells
    Yu, Chunwei
    Zhang, Jun
    Li, Jinhua
    Liu, Ping
    Wei, Peihai
    Chen, Lingxin
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 247 - 255
  • [42] Fluorescent probe for copper(II) ion based on a rhodamine spirolactame derivative, and its application to fluorescent imaging in living cells
    Chunwei Yu
    Jun Zhang
    Jinhua Li
    Ping Liu
    Peihai Wei
    Lingxin Chen
    Microchimica Acta, 2011, 174 : 247 - 255
  • [43] A novel quinoline-based fluorescent sensor for imaging Copper (II) in living cells
    Zhou, Chen
    Liu, Heng
    Zhang, Yinan
    MAIN GROUP CHEMISTRY, 2018, 17 (01) : 53 - 61
  • [44] A highly sensitive turn-on fluorescent chemosensor for recognition of Zn(II) ions and its application in live cells imaging
    Wang, Peng
    Wu, Jiang
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 386 (386)
  • [45] A Highly Zinc(II)-Selective Fluorescent Sensor Based on 8-Aminoquinoline and Its Application in Biological Imaging
    Xie, Guoqiang
    Xi, Pinxian
    Wang, Xiao
    Zhao, Xuefei
    Huang, Liang
    Chen, Fengjuan
    Wu, Yongjie
    Yao, Xiaojun
    Zeng, Zhengzhi
    EUROPEAN JOURNAL OF INORGANIC CHEMISTRY, 2011, (19) : 2927 - 2931
  • [46] Highly Selective Fluorescent Probe for the Detection of Copper (II) and Its Application in Live Cell Imaging
    Guo, Zhihao
    Wang, Xiuji
    Wei, Pei
    Gao, Yihua
    Li, Qin
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2019, 2019
  • [47] Highly selective and sensitive peptide-based fluorescent chemosensor for detection of Zinc(II) ions in aqueous medium and living cells
    Wang, Peng
    Wu, Xuehua
    Wu, Jiang
    Liao, Yunwen
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2019, 382
  • [48] A highly sensitive and selective fluorescent molecular sensor for Pb(II) based on a calix[4]arene bearing four dansyl groups
    Métivier, R
    Leray, I
    Valeur, B
    CHEMICAL COMMUNICATIONS, 2003, (08) : 996 - 997
  • [49] Fluorescent ion-imprinted sensor for selective and sensitive detection of copper (II) ions
    Xu, Zhifeng
    Deng, Peihong
    Li, Junhua
    Tang, Siping
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2095 - 2104
  • [50] A highly selective and sensitive 1,8-naphthalimide-based fluorescent sensor for Zn2+ imaging in living cells
    Liu, Daying
    Zhao, Ye
    Shi, Jun
    Zhu, Hualing
    Zhang, Tingting
    Qi, Pengpeng
    Chen, Jiatong
    Yang, Guangming
    He, Huarui
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2019, 29 (18) : 2646 - 2649