Development of an analytical method for the targeted screening and multi-residue quantification of environmental contaminants in urine by liquid chromatography coupled to high resolution mass spectrometry for evaluation of human exposures

被引:29
作者
Cortejade, A. [1 ]
Kiss, A. [1 ]
Cren, C. [1 ]
Vulliet, E. [1 ]
Bulete, A. [1 ]
机构
[1] Univ Lyon 1, Inst Sci Analyt, ENS Lyon, UMR5280,CNRS, F-69100 Villeurbanne, France
关键词
Exposome; LC-HRMS; Urine; ToF; Organic contaminants; SOLID-PHASE EXTRACTION; LC-MS/MS METHOD; RAPID-DETERMINATION; UV-FILTERS; PESTICIDE-RESIDUES; GAS-CHROMATOGRAPHY; ENDOCRINE ACTIVITY; SAMPLE PREPARATION; METHOD VALIDATION; VETERINARY DRUGS;
D O I
10.1016/j.talanta.2015.06.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 43 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ, The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:694 / 706
页数:13
相关论文
共 67 条
[1]   Multiclass method for fast determination of veterinary drug residues in baby food by ultra-high-performance liquid chromatography-tandem mass spectrometry [J].
Aguilera-Luiz, M. M. ;
Martinez Vidal, J. L. ;
Romero-Gonzalez, R. ;
Garrido Frenich, A. .
FOOD CHEMISTRY, 2012, 132 (04) :2171-2180
[2]  
[Anonymous], 2005, INT C HARM TECHN REQ
[3]  
ANSES, 2011, CAMP NAT OCC RES MED
[4]  
ANSES (Agence francaise de securite sanitaire de l'environnement et du travail), 2010, EXP POP GEN RES PEST
[5]   Urinary excretion of alkylphosphates in the general population (Italy) [J].
Aprea, C ;
Sciarra, G ;
Orsi, D ;
Boccalon, P ;
Sartorelli, P ;
Sartorelli, E .
SCIENCE OF THE TOTAL ENVIRONMENT, 1996, 177 :37-41
[6]   Development and validation of a LC-MS/MS method for homocysteine thiolactone in plasma and evaluation of its stability in plasma samples [J].
Arora, Beauty ;
Narayanasamy, Angayarkanni ;
Nirmal, Jayabalan ;
Halder, Nabanita ;
Patnaik, Santosh ;
Ravi, Alok K. ;
Velpandian, Thirumurthy .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 944 :49-54
[7]   A multi-class bioanalytical methodology for the determination of bisphenol A diglycidyl ethers, p-hydroxybenzoic acid esters, benzophenone-type ultraviolet filters, triclosan, and triclocarban in human urine by liquid chromatography-tandem mass spectrometry [J].
Asimakopoulos, Alexandros G. ;
Wang, Lei ;
Thomaidis, Nikolaos S. ;
Kannan, Kurunthachalam .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1324 :141-148
[8]   Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry I. Screening analysis [J].
Badoud, F. ;
Grata, E. ;
Perrenoud, L. ;
Avois, L. ;
Saugy, M. ;
Rudaz, S. ;
Veuthey, J. -L. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (20) :4423-4433
[9]  
Baldi I., 2008, CANC ENV
[10]   MicroQuEChERS-nanoliquid chromatography-nanospray-tandem mass spectrometry for the detection and quantification of trace pharmaceuticals in benthic invertebrates [J].
Berlioz-Barbier, Alexandra ;
Baudot, Robert ;
Wiest, Laure ;
Gust, Marion ;
Garric, Jeanne ;
Cren-Olive, Cecile ;
Bulete, Audrey .
TALANTA, 2015, 132 :796-802