Study on Spread of Fire Overflow on Building Facades with Insulation Materials

被引:0
作者
Li, Yanfeng [1 ]
Xu, Congcong [1 ]
Xing, Xuefei [1 ]
Zhang, Jin [2 ]
Hu, Cheng [2 ]
机构
[1] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[2] Beijing Municipal Inst Labor Protect, Beijing 10054, Peoples R China
来源
PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4 | 2013年 / 405-408卷
关键词
Building insulation; Facade opening; FDS; Fire overflow;
D O I
10.4028/www.scientific.net/AMM.405-408.2438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fire overflow on exterior wall with thermal insulation system has been studied by numerical simulation. The spread laws of fire overflow are analyzed through the temperature distribution near the window. The computational results are compared with those of test in the Exterior Insulation Fire Barrier Technical Guidelines (EIFBTG). It has been found that the calculated maximum temperature points is closed to the test on the first floor, the first ceiling, and the points near the above two windows. However, there are differences between two kinds of results above two floors and ceilings, and the points near the first window. It has also shown that when the HEIR is 7.5KW, the scope of damage of exterior thermal insulation layer is about 15 square meters near the window. The research would provide reference for fire protection design of exterior wall thermal insulation in the high-rise buildings.
引用
收藏
页码:2438 / +
页数:2
相关论文
共 7 条
[1]  
[Anonymous], 2012, EXTERIOR INSULATION
[2]  
CHOW W.K., 1999, APPL FIRE SCI, V9, P275
[3]   Large eddy simulation of fire-induced buoyancy driven plume dispersion in an urban street canyon under perpendicular wind flow [J].
Hu, L. H. ;
Huo, R. ;
Yang, D. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (01) :394-406
[4]  
Liu Jianmin, 2008, FIRE TECHNIQUE PRODU, P20
[5]  
Zhang HX, 2007, THESIS
[6]  
Zhou Ci, 2003, J LIAONING ENG TECHN, V22, P524
[7]  
ZHUO Ping, 2011, FIRE SCI TECHNOLOGY, V30, P8