Theory and Application of Audio-Based Assessment of Cough

被引:30
作者
Shi, Yan [1 ]
Liu, He [1 ]
Wang, Yixuan [1 ]
Cai, Maolin [1 ]
Xu, Weiqing [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
关键词
OBJECTIVE ASSESSMENT; AUTOMATED COUGH; FREQUENCY; VALIDATION; SYSTEM; GUIDELINES; CHILDREN; ADULT; SOUND;
D O I
10.1155/2018/9845321
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cough is a common symptom of many respiratory diseases. Many medical literatures underline that a system for the automatic, objective, and reliable detection of cough events is important and very promising to detect pathology severity in chronic cough disease. In order to track the development status of an audio-based cough monitoring system, we briefly described the history of objective cough detection and then illustrated the cough sound generating principle. The probable endpoints of cough clinical studies, including cough frequency, intensity of coughing, and acoustic properties of cough sound, were analyzed in this paper. Finally, we introduce some successful cough monitoring equipment and their recognition algorithm in detail. It can be obtained that, firstly, acoustic variability of cough sounds within and between individuals makes it difficult to assess the intensity of coughing. Furthermore, now great progress in audio-based cough detection is being made. Moreover, accurate portable objective monitoring systems will be available and widely used in home care and clinical trials in the near future.
引用
收藏
页数:10
相关论文
共 79 条
[1]  
Abaza Ayman A, 2009, Cough, V5, P8, DOI 10.1186/1745-9974-5-8
[2]   Cough Sound Analysis Can Rapidly Diagnose Childhood Pneumonia [J].
Abeyratne, Udantha R. ;
Swarnkar, Vinayak ;
Setyati, Amalia ;
Triasih, Rina .
ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (11) :2448-2462
[3]  
Amoh J, 2015, BIOMED CIRC SYST C, P438
[4]  
Amoh Justice, 2013, Critical Reviews in Biomedical Engineering, V41, P457
[5]   Automatic cough segmentation from non-contact sound recordings in pediatric wards [J].
Amrulloh, Yusuf A. ;
Abeyratne, Udantha R. ;
Swarnkar, Vinayak ;
Triasih, Rina ;
Setyati, Amalia .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 21 :126-136
[6]  
[Anonymous], INT J NEURAL SYSTEMS
[7]  
Barry Samantha J, 2006, Cough, V2, P8, DOI 10.1186/1745-9974-2-8
[8]  
Barton Antony, 2012, Cough, V8, P12, DOI 10.1186/1745-9974-8-12
[9]  
BICKERMAN H A, 1958, J Chronic Dis, V8, P629, DOI 10.1016/0021-9681(58)90054-7
[10]   The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough [J].
Birring, S. S. ;
Fleming, T. ;
Matos, S. ;
Raj, A. A. ;
Evans, D. H. ;
Pavord, I. D. .
EUROPEAN RESPIRATORY JOURNAL, 2008, 31 (05) :1013-1018