Penetration of corrosion products and corrosion-induced cracking in reinforced cementitious materials: Experimental investigations and numerical simulations

被引:99
作者
Michel, Alexander [1 ]
Pease, Brad J. [2 ]
Peterova, Adela [3 ]
Geiker, Mette R. [1 ,4 ]
Stang, Henrik [1 ]
Thybo, Anna Emilie A. [1 ]
机构
[1] Tech Univ Denmark, Dept Civil Engn, DK-2800 Lyngby, Denmark
[2] SIA Primekss, Riga, Latvia
[3] Prague Inst Chem Technol, CR-16628 Prague, Czech Republic
[4] Norwegian Univ Sci & Technol NTNU, Dept Struct Engn, Trondheim, Norway
关键词
Corrosion; Crack detection; Non-destructive testing (NDT); Reinforcement; Modelling; FEM; COVER CRACKING; INITIATION; TIME; STEEL; MODEL;
D O I
10.1016/j.cemconcomp.2013.04.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes experimental investigations on corrosion-induced deterioration in reinforced cementitious materials and the subsequent development and implementation of a novel conceptual model. Rejnforced mortar specimens of varying water-to-cement ratios were subjected to current-induced corrosion (10, 50, and 100 mu A/cm(2)). X-ray attenuation measurements and visual investigations provided both qualitative and quantitative information on the penetration of solid corrosion products into the surrounding cementitious matrix. X-ray attenuation measurements provided time- and location-dependent concentrations of corrosion products averaged through the specimen thickness. Digital image correlation (DIC) was used to measure corrosion-induced deformations including deformations between steel and cementitious matrix as well as formation and propagation of corrosion-induced cracks. Based on experimental observations, a conceptual model was developed to describe the penetration of solid corrosion products into capillary pores of the cementitious matrix. Only capillary pores within a corrosion accommodating region (CAR), i.e. in close proximity of the steel reinforcement, were considered accessible for corrosion products. The conceptual model was implemented into a FEM based cracking model and compared to experimental results provided in the literature and obtained from DIC measurements. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:75 / 86
页数:12
相关论文
共 36 条
[21]  
Michel A, 2012, P ICDC INT C DUR CON
[22]   Monitoring reinforcement corrosion and corrosion-induced cracking using non-destructive x-ray attenuation measurements [J].
Michel, Alexander ;
Pease, Brad J. ;
Geiker, Mette R. ;
Stang, Henrik ;
Olesen, John Forbes .
CEMENT AND CONCRETE RESEARCH, 2011, 41 (11) :1085-1094
[23]   COVER CRACKING AS A FUNCTION OF REBAR CORROSION .2. NUMERICAL-MODEL [J].
MOLINA, FJ ;
ALONSO, C ;
ANDRADE, C .
MATERIALS AND STRUCTURES, 1993, 26 (163) :532-548
[24]  
Pease B., 2009, CONCRETELIFE 09
[25]  
Pease B.J., 2010, THESIS TU DENMARK KG
[26]  
Pease BJ, 2012, P IABAMAS 2012 6 INT
[27]  
Pease BJ, 2012, P MICR AMST NETH
[28]   Monitoring moisture movements in building materials using X-ray attenuation: Influence of beam-hardening of polychromatic X-ray photon beams [J].
Pease, Brad J. ;
Scheffler, Gregor A. ;
Janssen, Hans .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 36 :419-429
[29]  
Pereira E., 2011, P INT C ADV CONSTR M
[30]  