A Flexible Near-Field Biosensor for Multisite Arterial Blood Flow Detection

被引:7
作者
Mohammed, Noor [1 ,2 ]
Cluff, Kim [2 ]
Sutton, Mark [2 ]
Villafana-Ibarra, Bernardo [2 ]
Loflin, Benjamin E. [2 ,3 ]
Griffith, Jacob L. [2 ,4 ]
Becker, Ryan [2 ,5 ]
Bhandari, Subash [2 ,6 ]
Alruwaili, Fayez [2 ,7 ]
Desai, Jaydip [2 ]
机构
[1] Univ Massachusetts, Dept Elect & Comp Engn, Amherst, MA 01003 USA
[2] Wichita State Univ, Dept Biomed Engn, Wichita, KS 67260 USA
[3] Indiana Univ Sch Med, Dept Orthopaed Surg, Indianapolis, IN 46202 USA
[4] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[5] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[6] Cornell Univ, Meinig Sch Biomed Engn, Ithaca, NY 14850 USA
[7] Rowan Univ, Dept Biomed Engn, Glassboro, NJ 08028 USA
基金
美国国家航空航天局; 美国国家科学基金会;
关键词
RF resonator; biosensor; microwave sensing; blood flow sensor; hemodynamics; wearable sensor; point-of-care technology; WAVE-FORM; SENSOR; PATCH;
D O I
10.3390/s22218389
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Modern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body's variable geometry to accurately detect those vital signs and to understand health better. Flexible radio frequency (RF) resonators are well poised to address this need by providing conformable bio-interfaces suitable for different anatomical locations. In this work, we develop a compact wearable RF biosensor that detects multisite hemodynamic events due to pulsatile blood flow through noninvasive tissue-electromagnetic (EM) field interaction. The sensor consists of a skin patch spiral resonator and a wearable transceiver. During resonance, the resonator establishes a strong capacitive coupling with layered dielectric tissues due to impedance matching. Therefore, any variation in the dielectric properties within the near-field of the coupled system will result in field perturbation. This perturbation also results in RF carrier modulation, transduced via a demodulator in the transceiver unit. The main elements of the transceiver consist of a direct digital synthesizer for RF carrier generation and a demodulator unit comprised of a resistive bridge coupled with an envelope detector, a filter, and an amplifier. In this work, we build and study the sensor at the radial artery, thorax, carotid artery, and supraorbital locations of a healthy human subject, which hold clinical significance in evaluating cardiovascular health. The carrier frequency is tuned at the resonance of the spiral resonator, which is 34.5 +/- 1.5 MHz. The resulting transient waveforms from the demodulator indicate the presence of hemodynamic events, i.e., systolic upstroke, systolic peak, dicrotic notch, and diastolic downstroke. The preliminary results also confirm the sensor's ability to detect multisite blood flow events noninvasively on a single wearable platform.
引用
收藏
页数:18
相关论文
共 49 条
[11]   Nanoscale flexoelectric energy harvesting [J].
Deng, Qian ;
Kammoun, Mejdi ;
Erturk, Alper ;
Sharma, Pradeep .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2014, 51 (18) :3218-3225
[12]  
Durney C.H., 1986, RADIOFREQUENCY RAD D
[13]  
Elgendi Mohamed, 2018, Diseases, V6, DOI 10.3390/diseases6010020
[14]   Comparative Design Study for Power Reduction in Organic Optoelectronic Pulse Meter Sensor [J].
Elsamnah, Fahed ;
Bilgaiyan, Anubha ;
Affiq, Muhamad ;
Shim, Chang-Hoon ;
Ishidai, Hiroshi ;
Hattori, Reiji .
BIOSENSORS-BASEL, 2019, 9 (02)
[15]  
Ermak G. P., 2012, 2012 22nd International Crimean Conference "Microwave & Telecommunication Technology" (CriMiCo 2012), P827
[16]   A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables [J].
Etemadi, Mozziyar ;
Inan, Omer T. ;
Heller, J. Alex ;
Hersek, Sinan ;
Klein, Liviu ;
Roy, Shuvo .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :280-288
[17]  
Ganguly P., 2016, P 2016 ASIA PACIFIC, P1
[18]   Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid-Volume Shifts [J].
Griffith, Jacob ;
Cluff, Kim ;
Eckerman, Brandon ;
Aldrich, Jessica ;
Becker, Ryan ;
Moore-Jansen, Peer ;
Patterson, Jeremy .
SENSORS, 2018, 18 (04)
[19]   A Chest-Laminated Ultrathin and Stretchable E-Tattoo for the Measurement of Electrocardiogram, Seismocardiogram, and Cardiac Time Intervals [J].
Ha, Taewoo ;
Tran, Jason ;
Liu, Siyi ;
Jang, Hongwoo ;
Jeong, Hyoyoung ;
Mitbander, Ruchika ;
Huh, Heeyong ;
Qiu, Yitao ;
Duong, Jason ;
Wang, Rebecca L. ;
Wang, Pulin ;
Tandon, Animesh ;
Sirohi, Jayant ;
Lu, Nanshu .
ADVANCED SCIENCE, 2019, 6 (14)
[20]   Toward Accurate Extraction of Respiratory Frequency From the Photoplethysmogram: Effect of Measurement Site [J].
Hartmann, Vera ;
Liu, Haipeng ;
Chen, Fei ;
Hong, Wentao ;
Hughes, Stephen ;
Zheng, Dingchang .
FRONTIERS IN PHYSIOLOGY, 2019, 10