A Flexible Near-Field Biosensor for Multisite Arterial Blood Flow Detection

被引:7
作者
Mohammed, Noor [1 ,2 ]
Cluff, Kim [2 ]
Sutton, Mark [2 ]
Villafana-Ibarra, Bernardo [2 ]
Loflin, Benjamin E. [2 ,3 ]
Griffith, Jacob L. [2 ,4 ]
Becker, Ryan [2 ,5 ]
Bhandari, Subash [2 ,6 ]
Alruwaili, Fayez [2 ,7 ]
Desai, Jaydip [2 ]
机构
[1] Univ Massachusetts, Dept Elect & Comp Engn, Amherst, MA 01003 USA
[2] Wichita State Univ, Dept Biomed Engn, Wichita, KS 67260 USA
[3] Indiana Univ Sch Med, Dept Orthopaed Surg, Indianapolis, IN 46202 USA
[4] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[5] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[6] Cornell Univ, Meinig Sch Biomed Engn, Ithaca, NY 14850 USA
[7] Rowan Univ, Dept Biomed Engn, Glassboro, NJ 08028 USA
基金
美国国家航空航天局; 美国国家科学基金会;
关键词
RF resonator; biosensor; microwave sensing; blood flow sensor; hemodynamics; wearable sensor; point-of-care technology; WAVE-FORM; SENSOR; PATCH;
D O I
10.3390/s22218389
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Modern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body's variable geometry to accurately detect those vital signs and to understand health better. Flexible radio frequency (RF) resonators are well poised to address this need by providing conformable bio-interfaces suitable for different anatomical locations. In this work, we develop a compact wearable RF biosensor that detects multisite hemodynamic events due to pulsatile blood flow through noninvasive tissue-electromagnetic (EM) field interaction. The sensor consists of a skin patch spiral resonator and a wearable transceiver. During resonance, the resonator establishes a strong capacitive coupling with layered dielectric tissues due to impedance matching. Therefore, any variation in the dielectric properties within the near-field of the coupled system will result in field perturbation. This perturbation also results in RF carrier modulation, transduced via a demodulator in the transceiver unit. The main elements of the transceiver consist of a direct digital synthesizer for RF carrier generation and a demodulator unit comprised of a resistive bridge coupled with an envelope detector, a filter, and an amplifier. In this work, we build and study the sensor at the radial artery, thorax, carotid artery, and supraorbital locations of a healthy human subject, which hold clinical significance in evaluating cardiovascular health. The carrier frequency is tuned at the resonance of the spiral resonator, which is 34.5 +/- 1.5 MHz. The resulting transient waveforms from the demodulator indicate the presence of hemodynamic events, i.e., systolic upstroke, systolic peak, dicrotic notch, and diastolic downstroke. The preliminary results also confirm the sensor's ability to detect multisite blood flow events noninvasively on a single wearable platform.
引用
收藏
页数:18
相关论文
共 49 条
[1]   Passive Self Resonant Skin Patch Sensor to Monitor Cardiac Intraventricular Stroke Volume Using Electromagnetic Properties of Blood [J].
Alruwaili, Fayez ;
Cluff, Kim ;
Griffith, Jacob ;
Farhoud, Hussam .
IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
[2]   Sensitivity Enhanced Vital Sign Detection Based on Antenna Reflection Coefficient Variation [J].
An, Yong-Jun ;
Yun, Gi-Ho ;
Yook, Jong-Gwan .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :319-327
[3]   Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators [J].
An, Yong-Jun ;
Kim, Byung-Hyun ;
Yun, Gi-Ho ;
Kim, Sung -Woo ;
Hong, Seung-Bum ;
Yook, Jong-Gwan .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :300-308
[4]   Wrist Pulse Detection System Based on Changes in the Near-Field Reflection Coefficient of a Resonator [J].
An, Yong-Jun ;
Yun, Gi-Ho ;
Kim, Sung Woo ;
Yook, Jong-Gwan .
IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2014, 24 (10) :719-721
[5]  
[Anonymous], Body Tissue Dielectric Parameters
[6]  
Becker R., 2019, RF RESONANT SKIN PAT
[7]   Mechanisms for interaction between RF fields and biological tissue [J].
Challis, LJ .
BIOELECTROMAGNETICS, 2005, :S98-S106
[8]   High Durable, Biocompatible, and Flexible Piezoelectric Pulse Sensor Using Single-Crystalline III-N Thin Film [J].
Chen, Jie ;
Liu, Haoran ;
Wang, Weijie ;
Nabulsi, Noor ;
Zhao, Wenbo ;
Kim, Ja Yeon ;
Kwon, Min-Ki ;
Ryou, Jae-Hyun .
ADVANCED FUNCTIONAL MATERIALS, 2019, 29 (37)
[9]   Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care [J].
Chen, Lisa Y. ;
Tee, Benjamin C. -K. ;
Chortos, Alex L. ;
Schwartz, Gregor ;
Tse, Victor ;
Lipomi, Darren J. ;
Wong, H. -S. Philip ;
McConnell, Michael V. ;
Bao, Zhenan .
NATURE COMMUNICATIONS, 2014, 5
[10]   Passive Wearable Skin Patch Sensor Measures Limb Hemodynamics Based on Electromagnetic Resonance [J].
Cluff, Kim ;
Becker, Ryan ;
Jayakumar, Balakumar ;
Han, Kiyun ;
Condon, Ernie ;
Dudley, Kenneth ;
Szatkowski, George ;
Pipinos, Iraklis I. ;
Amick, Ryan Z. ;
Patterson, Jeremy .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (04) :847-856