Microextraction by Packed Molecularly Imprinted Polymer Combined Ultra-High-Performance Liquid Chromatography for the Determination of Levofloxacin in Human Plasma

被引:24
作者
Meng, Jia [1 ,2 ]
Wang, Xu [3 ]
机构
[1] Tianjin Med Univ, Hosp 2, Dept Kidney Dis, Tianjin 300211, Peoples R China
[2] Tianjin Med Univ, Hosp 2, Blood Purificat Ctr, Tianjin 300211, Peoples R China
[3] Tianjin Med Univ, Hosp 2, Tianjin Inst Urol, Dept Urol, Tianjin 300211, Peoples R China
关键词
DEEP EUTECTIC SOLVENT; SIMULTANEOUS QUANTIFICATION; LOCAL-ANESTHETICS; SORBENT MEPS; MOXIFLOXACIN; ANTIBIOTICS; PROSTATE; SAMPLES; PURIFICATION; GATIFLOXACIN;
D O I
10.1155/2019/4783432
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fluoroquinolones are considered as gold standard for the prevention of bacterial infections. To improve assessment of antibacterial efficacy, a novel method for determination of levofloxacin was developed and validated. Deep eutectic solvents (DESs) as only green solvent were used as a porogen for preparation of water-compatible molecularly imprinted polymers (MIPs) with a pseudotemplate. The DESs-MIPs were characterized in detail, including scanning electron microscope, nitrogen sorption porosimetry, and Fourier transform-infrared spectra. Clearly, the maximum binding capacity of levofloxacin on DESs-MIPs in water and methanol was 0.216 and 0.077 mu mol g(-1), respectively. The DESs-MIPs as adsorbing materials were applied in microextraction by packed sorbent (MEPS), and the DESs-MIPs-MEPS conditions were optimized. The DESs-MIPs-MEPS coupled with ultra-high-performance liquid chromatography (UHPLC) was used to determine levofloxacin in human plasma. The method was found linear over 0.05-10 mu g mL(-1) with coefficient of correlation equal to 0.9988. The limit of detection and limit of quantification were 0.012 and 0.04 mu g mL(-1), respectively. At three spiked levels, the precision of proposed method was between 95.3% and 99.7% with intraday and interday relative standard deviations <= 8.9%. Finally, the developed method was used to examine levofloxacin from human plasma of 20 hospitalized patients after transrectal ultrasound-guided prostate biopsy, and the average concentration (+/- SD) of levofloxacin was 2.35 +/- 0.99 mu g mL(-1) in plasma.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Determination of sulfadiazine in eggs using molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography
    He, Xiuping
    Tan, Liju
    Wu, Wei
    Wang, Jiangtao
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (11) : 2204 - 2212
  • [42] Preconcentration of Nicotinamide Using Molecularly Imprinted Microspheres for Solid-phase Extraction with Determination by High-performance Liquid Chromatography
    Wu, Dengyu
    Li, Li
    Zhu, Yongyan
    Li, Zhijian
    Zhu, Quanhong
    ANALYTICAL LETTERS, 2017, 50 (16) : 2560 - 2578
  • [43] Determination of metoprolol enantiomers in human plasma and saliva samples utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry
    Elmongy, Hatem
    Ahmed, Hytham
    Wahbi, Abdel-Aziz
    Amini, Ahmad
    Colmsjo, Anders
    Abdel-Rehim, Mohamed
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (08) : 1309 - 1317
  • [44] Determination of pesticide residues in ginseng by dispersive liquid-liquid microextraction and ultra high performance liquid chromatography-tandem mass spectrometry
    Chen, Lina
    Yin, Lihua
    Song, Fengrui
    Liu, Zhiqiang
    Zheng, Zhong
    Xing, Junpeng
    Liu, Shuying
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 917 : 71 - 77
  • [45] Determination of ciprofloxacin in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with fluorescence detection
    Lian, Ziru
    Wang, Jiangtao
    MARINE POLLUTION BULLETIN, 2016, 111 (1-2) : 411 - 417
  • [46] In-tube solid-phase microextraction with a dummy molecularly imprinted monolithic capillary coupled to ultra-performance liquid chromatography-tandem mass spectrometry to determine cannabinoids in plasma samples
    Marchioni, Camila
    Vieira, Tatiana Manzini
    Miller Crotti, Antonio Eduardo
    Crippa, Jose Alexandre
    Costa Queiroz, Maria Eugenia
    ANALYTICA CHIMICA ACTA, 2020, 1099 : 145 - 154
  • [47] Determination of plasma concentrations of levofloxacin by high performance liquid chromatography for use at a multidrug-resistant tuberculosis hospital in Tanzania
    Ebers, Andrew
    Stroup, Suzanne
    Mpagama, Stellah
    Kisonga, Riziki
    Lekule, Isaack
    Liu, Jie
    Heysell, Scott
    PLOS ONE, 2017, 12 (01):
  • [48] Ionic liquid-based single-drop liquid-phase microextraction combined with high-performance liquid chromatography for the determination of sulfonamides in environmental water
    Guo, Xueping
    Yin, Daqiang
    Peng, Jingfeng
    Hu, Xialin
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (03) : 452 - 458
  • [49] Magnetic molecularly imprinted polymer based - micro-solid phase extraction of cocaine and metabolites in plasma followed by high performance liquid chromatography - tandem mass spectrometry
    Sanchez-Gonzalez, Juan
    Barreiro-Grille, Tania
    Cabarcos, Pamela
    Jesus Tabernero, Maria
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    MICROCHEMICAL JOURNAL, 2016, 127 : 206 - 212
  • [50] Simultaneous quantification of levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin in microvolumes of human plasma using high-performance liquid chromatography with ultraviolet detection
    Zheng, Yi
    Wang, Ziqing
    Lui, Gabrielle
    Hirt, Deborah
    Treluyer, Jean-Marc
    Benaboud, Sihem
    Aboura, Radia
    Gana, Ines
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (05)