Microextraction by Packed Molecularly Imprinted Polymer Combined Ultra-High-Performance Liquid Chromatography for the Determination of Levofloxacin in Human Plasma

被引:24
作者
Meng, Jia [1 ,2 ]
Wang, Xu [3 ]
机构
[1] Tianjin Med Univ, Hosp 2, Dept Kidney Dis, Tianjin 300211, Peoples R China
[2] Tianjin Med Univ, Hosp 2, Blood Purificat Ctr, Tianjin 300211, Peoples R China
[3] Tianjin Med Univ, Hosp 2, Tianjin Inst Urol, Dept Urol, Tianjin 300211, Peoples R China
关键词
DEEP EUTECTIC SOLVENT; SIMULTANEOUS QUANTIFICATION; LOCAL-ANESTHETICS; SORBENT MEPS; MOXIFLOXACIN; ANTIBIOTICS; PROSTATE; SAMPLES; PURIFICATION; GATIFLOXACIN;
D O I
10.1155/2019/4783432
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fluoroquinolones are considered as gold standard for the prevention of bacterial infections. To improve assessment of antibacterial efficacy, a novel method for determination of levofloxacin was developed and validated. Deep eutectic solvents (DESs) as only green solvent were used as a porogen for preparation of water-compatible molecularly imprinted polymers (MIPs) with a pseudotemplate. The DESs-MIPs were characterized in detail, including scanning electron microscope, nitrogen sorption porosimetry, and Fourier transform-infrared spectra. Clearly, the maximum binding capacity of levofloxacin on DESs-MIPs in water and methanol was 0.216 and 0.077 mu mol g(-1), respectively. The DESs-MIPs as adsorbing materials were applied in microextraction by packed sorbent (MEPS), and the DESs-MIPs-MEPS conditions were optimized. The DESs-MIPs-MEPS coupled with ultra-high-performance liquid chromatography (UHPLC) was used to determine levofloxacin in human plasma. The method was found linear over 0.05-10 mu g mL(-1) with coefficient of correlation equal to 0.9988. The limit of detection and limit of quantification were 0.012 and 0.04 mu g mL(-1), respectively. At three spiked levels, the precision of proposed method was between 95.3% and 99.7% with intraday and interday relative standard deviations <= 8.9%. Finally, the developed method was used to examine levofloxacin from human plasma of 20 hospitalized patients after transrectal ultrasound-guided prostate biopsy, and the average concentration (+/- SD) of levofloxacin was 2.35 +/- 0.99 mu g mL(-1) in plasma.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Microextraction by packed molecularly imprinted polymer followed by ultra-high performance liquid chromatography for determination of fipronil and fluazuron residues in drinking water and veterinary clinic wastewater
    Teixeira, Roseane Andrade
    Fonseca Dinali, Laise Aparecida
    Silva, Camilla Fonseca
    de Oliveira, Hanna Leijoto
    Maria da Silva, Anny Talita
    Nascimento Jr, Clebio Soares
    Borges, Keyller Bastos
    MICROCHEMICAL JOURNAL, 2021, 168
  • [2] Magnetic molecularly imprinted polymer combined with high performance liquid chromatography for selective extraction and determination of the metabolic content of quercetin in rat plasma
    Xie, Zenghui
    Chen, Yanli
    Zhang, Lanyun
    Hu, Xujia
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2020, 31 (01) : 53 - 71
  • [3] Molecularly imprinted polymer-based solid phase extraction combined high performance liquid chromatography for determination of fluoroquinolones in milk
    Wang, Geng Nan
    Yang, Kun
    Liu, Hui Zhi
    Feng, Meng Xiao
    Wang, Jian Ping
    ANALYTICAL METHODS, 2016, 8 (27) : 5511 - 5518
  • [4] Determination of Acephate in Vegetables by Magnetic Molecularly Imprinted Polymer Isolation Coupled with High-Performance Liquid Chromatography
    Gao, Lei
    Piao, Chunying
    Chen, Ligang
    ANALYTICAL LETTERS, 2015, 48 (05) : 752 - 765
  • [5] Application of Molecularly Imprinted Polymer for Extraction and Determination of Nalidixic Acid by High-Performance Liquid Chromatography
    Panahi, Homayon Ahmad
    Mahabadi, Somayeh Ashrafi
    SEPARATION SCIENCE AND TECHNOLOGY, 2015, 50 (05) : 683 - 689
  • [6] Microextraction by packed sorbent liquid chromatography with time-of-flight mass spectrometry of triazines employing a molecularly imprinted polymer
    Andrade, Felipe Nascimento
    Santos-Neto, Alvaro Jose
    Lancas, Fernando Mauro
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (21) : 3150 - 3156
  • [7] Determination of urinary trans,trans-muconic acid using molecularly imprinted polymer in microextraction by packed sorbent followed by liquid chromatography with ultraviolet detection
    Soleimani, Esmaeel
    Bahrami, Abdulrahman
    Afkhami, Abbas
    Shahna, Farshid Ghorbani
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1061 : 65 - 71
  • [8] Determination of benzimidazoles in beef by molecularly imprinted boron nitride composite based dispersive solid phase microextraction and ultra performance liquid chromatography
    Wang, Su Han
    Zang, Xiao Huan
    Zhang, Shuai Hua
    Wang, Jian Ping
    MICROCHEMICAL JOURNAL, 2022, 179
  • [9] Selective extraction of zolpidem from plasma using molecularly imprinted polymer followed by high performance liquid chromatography
    Alimohammadi, Zinat
    Pourmoslemi, Shabnam
    MICROCHEMICAL JOURNAL, 2021, 162
  • [10] Synthesis of a molecularly imprinted polymer and its application for microextraction by packed sorbent for the determination of fluoroquinolone related compounds in water
    Prieto, A.
    Schrader, S.
    Bauer, C.
    Moeder, M.
    ANALYTICA CHIMICA ACTA, 2011, 685 (02) : 146 - 152