Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study

被引:102
|
作者
Savoldelli, Georges L. [1 ,2 ]
Schiffer, Eduardo [1 ]
Abegg, Christoph [1 ]
Baeriswyl, Vincent [1 ]
Clergue, Francois [1 ]
Waeber, Jean-Luc [1 ]
机构
[1] Univ Hosp Geneva, Dept Anaesthesiol Pharmacol & Intens Care, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Fac Med, Unit Dev & Res Med Educ, CH-1211 Geneva 4, Switzerland
关键词
Airtraq laryngoscope; anaesthetic equipement; education; glidescope videolaryngoscope; intratracheal; intubation; laryngoscopes; McGrath videolaryngoscope; CERVICAL-SPINE MOTION; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; DIFFICULT; VIDEOLARYNGOSCOPE; STABILIZATION; STYLET;
D O I
10.1097/EJA.0b013e3283269ff4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective Several video and optical laryngoscopes have been developed but few have been compared in terms of their learning curves and efficacy. Using a manikin with normal airways we compared the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes. Methods Sixty anaesthetists (20 staff, 20 residents and 20 nurses) participated in the study. All subjects were novice with the new devices. They intubated a Laerdal SimMan manikin (with normal airway) five times in a row with all laryngoscopes. The sequence of use of the devices was randomized. Before using a device, a presentation and a demonstration were provided. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use. Results The Airtraq had the most favourable learning curve and mirrored the Macintosh after two intubation attempts. The Glidescope and McGrath had steep learning curves but, after five attempts, differences persisted when compared with the Macintosh and Airtraq. Time taken to visualize the glottis was similar but time taken to position the endotracheal tube was shorter for the Airtraq when compared with the Glidescope and McGrath. Indirect laryngoscopes seemed to have advantages over the Macintosh blade in terms of laryngeal exposure and potential dental trauma. Conclusions In a 'normal airway' model, intubation skills with the new devices appeared to be rapidly mastered. The three indirect laryngoscopes provided a better glottic exposure than the Macintosh. The Airtraq displayed the most favourable learning curve, probably reflecting differences in the techniques of endotracheal tube placement: guiding channel versus steering technique. Eur J Anaesthesiol 26:554-558 (C) 2009 European Society of Anaesthesiology.
引用
收藏
页码:554 / 558
页数:5
相关论文
共 50 条
  • [1] A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study
    Owada, Gen
    Mihara, Takahiro
    Inagawa, Gaku
    Asakura, Ayako
    Goto, Takahisa
    Ka, Koui
    PLOS ONE, 2017, 12 (02):
  • [2] Endotracheal intubation with the GlideScope®, the Airtraq®, the McGrath® videolaryngoscope and direct laryngoscopy: A comparative study on an infant manikin
    Orliaguet, G. A.
    Blot, R. -M.
    Bourdaud, N.
    Egan, M.
    Dogaru, E.
    Salvi, N.
    Gall, O.
    Carli, P.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 (12): : 844 - 849
  • [3] A randomised crossover trial comparing the Airtraq® NT, McGrath® MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin
    Angel Gomez-Rios, Manuel
    Pinegger, Stephan
    de Carrillo Mantilla, Maria
    Vizcaino, Lucia
    Barreto-Calvo, Purisima
    Paech, Michael J.
    Gomez-Rios, David
    Lopez-Calvino, Beatriz
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2016, 66 (03): : 289 - 297
  • [4] A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study
    Ray, D. C.
    Billington, C.
    Kearns, P. K.
    Kirkbride, R.
    Mackintosh, K.
    Reeve, C. S.
    Robinson, N.
    Stewart, C. J.
    Trudeau, T.
    ANAESTHESIA, 2009, 64 (11) : 1207 - 1210
  • [5] Comparison of the Glidescope® and Airtraq® optical laryngoscopes in patients undergoing direct microlaryngoscopy
    Lange, M.
    Frommer, M.
    Redel, A.
    Trautner, H.
    Hampel, J.
    Kranke, P.
    Kehl, F.
    Scholtz, L. U.
    Roewer, N.
    ANAESTHESIA, 2009, 64 (03) : 323 - 328
  • [6] Comparison of the Macintosh, GlideScope®, Airtraq®, and King Vision™ laryngoscopes in routine airway management
    Al-Ghamdi, Abdulmohsen A.
    El Tahan, Mohamed R.
    Khidr, Alaa M.
    MINERVA ANESTESIOLOGICA, 2016, 82 (12) : 1278 - +
  • [7] Randomized controlled trial of the AP Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study
    Burdett, E.
    Ross-Anderson, D. J.
    Makepeace, J.
    Bassett, P. A.
    Clarke, S. G.
    Mitchell, V.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (06) : 983 - 988
  • [8] Comparison of Bullard and Airtraq laryngoscopes with conventional laryngoscopy in a manikin study of simulated difficult intubation
    Legrand, Maria A. -L.
    Steinmann, Daniel
    Priebe, Hans-Joachim
    Mols, Georg
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (07) : 343 - 350
  • [9] Intubation using the Miller and Airtraq (TM) laryngoscopes: A paediatric manikin study
    Castle, N.
    Gangaram, P.
    Tong, J. L.
    Spencer, N. H.
    Pillay, B.
    Pillay, Y.
    AFRICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 1 (01) : 25 - 29
  • [10] Can the new McGrath laryngoscope rival the GlideScope Ranger portable video laryngoscope? A randomized manikin study
    Kim, Wonhee
    Choi, Hyuk Joong
    Lim, Taeho
    Kang, Bo Seung
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (10) : 1225 - 1229