Electrochemical deposition of gold nanoparticles on graphite rod for glucose biosensing

被引:75
作者
German, Natalija [1 ,3 ]
Ramanavicius, Arunas [2 ,3 ]
Ramanaviciene, Almira [2 ]
机构
[1] Ctr Innovat Med, Div Immunol, State Res Inst, LT-01102 Vilnius, Lithuania
[2] Vilnius Univ, Fac Chem, Ctr Nanotechnol & Mat Sci NanoTechnas, LT-03225 Vilnius, Lithuania
[3] Ctr Phys Sci & Technol, State Sci Res Inst, Inst Semicond Phys, Lab BioNanotechnol,Div Mat Sci & Elect, LT-01108 Vilnius, Lithuania
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2014年 / 203卷
关键词
Gold nanoparticles; Electrochemical deposition; Cyclic voltammetry; Glucose oxidase; Glucose biosensor; DIRECT ELECTRON-TRANSFER; COVALENT ATTACHMENT; AU-ELECTRODES; OXIDASE; ENZYME; IMMOBILIZATION; FILM; RECONSTITUTION; CONSTRUCTION; FERROCENE;
D O I
10.1016/j.snb.2014.06.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor based on glucose oxidase (GOx) immobilized on gold nanoparticles (Au-NPs) electrochemically predeposited on the surface of graphite rod (GR) electrode was developed (GOx/Au-NPs/GR). Main analytical characteristics of this biosensor were determined and compared with those determined using a biosensor setup without Au-NP modification (GOx/GR). The highest analytical signal of GOx/Au-NPs/GR electrode was observed after 13 nm Au-NP deposition on the electrode from 0.8 nmol L-1 solution lasting 20 min, when cyclic voltammetry was performed in the range from 0.0 to + 1.0 V vs Ag/AgCl. The best analytical characteristics of the developed biosensor were obtained after 25 mg mL(-1) GOx immobilization on the Au-NPs/GR electrode. Analytical signal registered using GOx/Au-NPs/GR electrode was 2.08 times higher in comparison to GOx/GR electrode. The registered currents of both electrodes were linearly dependent on glucose concentration in the range of 0.1-10 mmol L-1. The developed GOx/AuNPs/GR electrode was characterized by high sensitivity, which was equal to 101.02 mu A mM(-1) cm(-2) in the linear glucose detection range. The limit of detection was 0.083 mmol L-1 with relative standard deviation of 6% for GOx/Au-NPs/GR electrode. This study demonstrates a successful practical exploitation of the developed biosensor in a human serum sample. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条
  • [41] A Novel Graphene-Grafted Gold Nanoparticles Composite for Highly Sensitive Electrochemical Biosensing
    Salahandish, Razieh
    Ghaffarinejad, Ali
    Naghib, Seyed Morteza
    Majidzadeh-A, Keivan
    Sanati-Nezhad, Amir
    IEEE SENSORS JOURNAL, 2018, 18 (06) : 2513 - 2519
  • [42] Gold microtubes assembling architecture for an impedimetric glucose biosensing system
    Bianchini, C.
    Zane, D.
    Curulli, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 734 - 742
  • [43] The use of different glucose oxidases for the development of an amperometric reagentless glucose biosensor based on gold nanoparticles covered by polypyrrole
    German, Natalija
    Kausaite-Minkstimiene, Asta
    Ramanavicius, Arunas
    Semashko, Tatiana
    Mikhailova, Raisa
    Ramanaviciene, Almira
    ELECTROCHIMICA ACTA, 2015, 169 : 326 - 333
  • [44] The electrochemical study of glucose oxidase on gold-coated magnetic iron oxide nanoparticles
    Eskandari, Khadijeh
    Zarei, Hajar
    Ghourchian, Hedayatollah
    Amoozadeh, Seyed-Mostafa
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (10) : 1254 - 1260
  • [45] Electrochemical biosensing with nanoparticles
    Merkoci, Arben
    FEBS JOURNAL, 2007, 274 (02) : 310 - 316
  • [46] Biosensing and electrochemical properties of flavin adenine dinucleotide (FAD)-Dependent glucose dehydrogenase (GDH) fused to a gold binding peptide
    Lee, Hyeryeong
    Lee, Yoo Seok
    Reginald, Stacy Simai
    Baek, Seungwoo
    Lee, Eun Mi
    Choi, In-Geol
    Chang, In Seop
    BIOSENSORS & BIOELECTRONICS, 2020, 165
  • [47] A Review of the Construction of Nano-Hybrids for Electrochemical Biosensing of Glucose
    Batool, Razia
    Rhouati, Amina
    Nawaz, Mian Hasnain
    Hayat, Akhtar
    Marty, Jean Louis
    BIOSENSORS-BASEL, 2019, 9 (01):
  • [48] The effect of colloidal solutions of gold nanoparticles on the performance of a glucose oxidase modified carbon electrode
    German, Natalija
    Ramanavicius, Arunas
    Voronovic, Jaroslav
    Oztekin, Yasemin
    Ramanaviciene, Almira
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 185 - 191
  • [49] Influence of Different Nanoparticles on Electrochemical Behavior of Glucose Biosensor
    Nenkova, R. D.
    Ivanov, Y. L.
    Godjevargova, T. I.
    PROCEEDINGS OF THE 6TH INTERNATIONAL ADVANCES IN APPLIED PHYSICS AND MATERIALS SCIENCE CONGRESS & EXHIBITION (APMAS 2016), 2017, 1809
  • [50] Electrochemical glucose biosensor based on silver nanoparticles/multiwalled carbon nanotubes modified electrode
    Chen, Lifei
    Xie, Huaqing
    Li, Jing
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (10) : 3323 - 3329