Electrochemical deposition of gold nanoparticles on graphite rod for glucose biosensing

被引:75
|
作者
German, Natalija [1 ,3 ]
Ramanavicius, Arunas [2 ,3 ]
Ramanaviciene, Almira [2 ]
机构
[1] Ctr Innovat Med, Div Immunol, State Res Inst, LT-01102 Vilnius, Lithuania
[2] Vilnius Univ, Fac Chem, Ctr Nanotechnol & Mat Sci NanoTechnas, LT-03225 Vilnius, Lithuania
[3] Ctr Phys Sci & Technol, State Sci Res Inst, Inst Semicond Phys, Lab BioNanotechnol,Div Mat Sci & Elect, LT-01108 Vilnius, Lithuania
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2014年 / 203卷
关键词
Gold nanoparticles; Electrochemical deposition; Cyclic voltammetry; Glucose oxidase; Glucose biosensor; DIRECT ELECTRON-TRANSFER; COVALENT ATTACHMENT; AU-ELECTRODES; OXIDASE; ENZYME; IMMOBILIZATION; FILM; RECONSTITUTION; CONSTRUCTION; FERROCENE;
D O I
10.1016/j.snb.2014.06.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor based on glucose oxidase (GOx) immobilized on gold nanoparticles (Au-NPs) electrochemically predeposited on the surface of graphite rod (GR) electrode was developed (GOx/Au-NPs/GR). Main analytical characteristics of this biosensor were determined and compared with those determined using a biosensor setup without Au-NP modification (GOx/GR). The highest analytical signal of GOx/Au-NPs/GR electrode was observed after 13 nm Au-NP deposition on the electrode from 0.8 nmol L-1 solution lasting 20 min, when cyclic voltammetry was performed in the range from 0.0 to + 1.0 V vs Ag/AgCl. The best analytical characteristics of the developed biosensor were obtained after 25 mg mL(-1) GOx immobilization on the Au-NPs/GR electrode. Analytical signal registered using GOx/Au-NPs/GR electrode was 2.08 times higher in comparison to GOx/GR electrode. The registered currents of both electrodes were linearly dependent on glucose concentration in the range of 0.1-10 mmol L-1. The developed GOx/AuNPs/GR electrode was characterized by high sensitivity, which was equal to 101.02 mu A mM(-1) cm(-2) in the linear glucose detection range. The limit of detection was 0.083 mmol L-1 with relative standard deviation of 6% for GOx/Au-NPs/GR electrode. This study demonstrates a successful practical exploitation of the developed biosensor in a human serum sample. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条
  • [31] Electrochemical Activity of Glutathione at a Graphite Electrode Modified with Gold Nanoparticles
    Perevezentseva, D. O.
    Skirdin, K. V.
    Gorchakov, E. V.
    Bimatov, V. I.
    ORIENTAL JOURNAL OF CHEMISTRY, 2015, 31 (02) : 837 - 844
  • [32] Dispersed Conducting Polymer Nanocomposites with Glucose Oxidase and Gold Nanoparticles for the Design of Enzymatic Glucose Biosensors
    German, Natalija
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    POLYMERS, 2021, 13 (13)
  • [33] Electrochemical study of mono-6-thio-β-cyclodextrin/ferrocene capped on gold nanoparticles: Characterization and application to the design of glucose amperometric biosensor
    Chen, Ming
    Diao, Guowang
    TALANTA, 2009, 80 (02) : 815 - 820
  • [34] Bienzymatic glucose biosensor based on direct electrochemistry of cytochrome c on gold nanoparticles/polyaniline nanospheres composite
    Xiang, Cuili
    Zou, Yongjin
    Qiu, Shujun
    Sun, Lixian
    Xu, Fen
    Zhou, Huaiying
    TALANTA, 2013, 110 : 96 - 100
  • [35] Comparative study of conductometric glucose biosensor based on gold and on magnetic nanoparticles
    Nouira, Wided
    Maaref, Abderrazak
    Elaissari, Hamid
    Vocanson, Francis
    Siadat, Maryam
    Jaffrezic-Renault, Nicole
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (01): : 298 - 303
  • [36] An ultrasensitive nanobiohybrid platform for glucose electrochemical biosensing based on ferrocenyl iminopropyl-modified silica nanoparticles
    Saadaoui, M.
    Braiek, M.
    Jaffrezic-Renault, N.
    Raouafi, N.
    RSC ADVANCES, 2016, 6 (52): : 46238 - 46243
  • [37] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    Natalija German
    Almira Ramanaviciene
    Jaroslav Voronovic
    Arunas Ramanavicius
    Microchimica Acta, 2010, 168 : 221 - 229
  • [38] Preparation of gold nanoparticles on eggshell membrane and their biosensing application
    Zheng, Baozhan
    Qian, Lei
    Yuan, Hongyan
    Xiao, Dan
    Yang, Xiupei
    Paau, Man Chin
    Choi, Martin M. F.
    TALANTA, 2010, 82 (01) : 177 - 183
  • [39] Nitrite electrochemical biosensing based on coupled graphene and gold nanoparticles
    Jiang, Jingjing
    Fan, Wenjuan
    Du, Xuezhong
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 343 - 348
  • [40] Novel Composite Electrode of the Reduced Graphene Oxide Nanosheets with Gold Nanoparticles Modified by Glucose Oxidase for Electrochemical Reactions
    Dong, Li
    Yu, Wenjuan
    Liu, Minmin
    Liu, Yang
    Shao, Qinsi
    Li, Aijun
    Yan, Wei
    Zhang, Jiujun
    CATALYSTS, 2019, 9 (09)