Electrochemical deposition of gold nanoparticles on graphite rod for glucose biosensing

被引:80
作者
German, Natalija [1 ,3 ]
Ramanavicius, Arunas [2 ,3 ]
Ramanaviciene, Almira [2 ]
机构
[1] Ctr Innovat Med, Div Immunol, State Res Inst, LT-01102 Vilnius, Lithuania
[2] Vilnius Univ, Fac Chem, Ctr Nanotechnol & Mat Sci NanoTechnas, LT-03225 Vilnius, Lithuania
[3] Ctr Phys Sci & Technol, State Sci Res Inst, Inst Semicond Phys, Lab BioNanotechnol,Div Mat Sci & Elect, LT-01108 Vilnius, Lithuania
关键词
Gold nanoparticles; Electrochemical deposition; Cyclic voltammetry; Glucose oxidase; Glucose biosensor; DIRECT ELECTRON-TRANSFER; COVALENT ATTACHMENT; AU-ELECTRODES; OXIDASE; ENZYME; IMMOBILIZATION; FILM; RECONSTITUTION; CONSTRUCTION; FERROCENE;
D O I
10.1016/j.snb.2014.06.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor based on glucose oxidase (GOx) immobilized on gold nanoparticles (Au-NPs) electrochemically predeposited on the surface of graphite rod (GR) electrode was developed (GOx/Au-NPs/GR). Main analytical characteristics of this biosensor were determined and compared with those determined using a biosensor setup without Au-NP modification (GOx/GR). The highest analytical signal of GOx/Au-NPs/GR electrode was observed after 13 nm Au-NP deposition on the electrode from 0.8 nmol L-1 solution lasting 20 min, when cyclic voltammetry was performed in the range from 0.0 to + 1.0 V vs Ag/AgCl. The best analytical characteristics of the developed biosensor were obtained after 25 mg mL(-1) GOx immobilization on the Au-NPs/GR electrode. Analytical signal registered using GOx/Au-NPs/GR electrode was 2.08 times higher in comparison to GOx/GR electrode. The registered currents of both electrodes were linearly dependent on glucose concentration in the range of 0.1-10 mmol L-1. The developed GOx/AuNPs/GR electrode was characterized by high sensitivity, which was equal to 101.02 mu A mM(-1) cm(-2) in the linear glucose detection range. The limit of detection was 0.083 mmol L-1 with relative standard deviation of 6% for GOx/Au-NPs/GR electrode. This study demonstrates a successful practical exploitation of the developed biosensor in a human serum sample. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 44 条
[1]   A glucose biosensor based on electrodeposited biocomposites of gold nanoparticles and glucose oxidase enzyme [J].
Bharathi, S ;
Nogami, M .
ANALYST, 2001, 126 (11) :1919-1922
[2]   Electrochemical organization of gold nanoclusters in three dimensions as thin films from an aminosilicate-stabilized gold sol and their characterization [J].
Bharathi, S ;
Nogami, M ;
Lev, O .
LANGMUIR, 2001, 17 (09) :2602-2609
[3]   CHARACTERIZATION OF A FERROCENE CONTAINING POLYACRYLAMIDE-BASED REDOX GEL FOR BIOSENSOR USE [J].
BU, HZ ;
MIKKELSEN, SR ;
ENGLISH, AM .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4071-4076
[4]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289
[5]   Direct electron transfer: An approach for electrochemical biosensors with higher selectivity and sensitivity [J].
Freire, RS ;
Pessoa, CA ;
Mello, LD ;
Kubota, LT .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) :230-243
[6]   Probing cysteine self-assembled monolayers over gold nanoparticles - Towards selective electrochemical sensors [J].
Galal, Ahmed ;
Atta, Nada F. ;
El-Ads, Ekram H. .
TALANTA, 2012, 93 :264-273
[7]   Glucose biosensor based on glucose oxidase and gold nanoparticles of different sizes covered by polypyrrole layer [J].
German, Natalija ;
Ramanavicius, Arunas ;
Voronovic, Jaroslav ;
Ramanaviciene, Almira .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2012, 413 :224-230
[8]   The effect of colloidal solutions of gold nanoparticles on the performance of a glucose oxidase modified carbon electrode [J].
German, Natalija ;
Ramanavicius, Arunas ;
Voronovic, Jaroslav ;
Oztekin, Yasemin ;
Ramanaviciene, Almira .
MICROCHIMICA ACTA, 2011, 172 (1-2) :185-191
[9]   Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles [J].
German, Natalija ;
Ramanaviciene, Almira ;
Voronovic, Jaroslav ;
Ramanavicius, Arunas .
MICROCHIMICA ACTA, 2010, 168 (3-4) :221-229
[10]   AMPEROMETRIC ENZYME ELECTRODES [J].
GREEN, MJ ;
HILL, HAO .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1237-1243