摘要
Purpose: To quantitatively compare a scanning liquid ion chamber electronic portal imaging device (SLIC-EPID) and an amorphous silicon flat panel (aSi) EPID with portal film in clinical applications using measures of landmark visibility and treatment review accuracy. Methods and Materials: Six radiation oncologists viewed 39 electronic portal images (EPIs) from the SLIC-EPID, 36 EPIs from the aSi-EPID, and portal films of each of these treatment fields. The physicians rated the clarity of anatomic landmarks in the portal images, and the scores were compared between EPID and film. Nine hundred portal image reviews were performed. EPID and film portal images were acquired with known setup errors in either phantom or cadaver treatments. Physicians identified the errors visually in portal films and with computerized analysis for EPID. Results: There were no statistically significant (p < 0.05) differences between film and SLIC-EPID in ratings of landmark clarity. Eleven of 12 landmarks were more visible in aSi-EPID than in film. Translational setup errors were identified with an average accuracy of 2.5 mm in film, compared to 1.5 mm with SLIC-EPID and 1.3 nun with aSi-EPID. Conclusions: Both EPIDs are clinically viable replacements for film, but aSi-EPID represents a significant advancement in image quality over film. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:584 / 591
页数:8
相关论文
共 31 条
  • [1] Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager
    Antonuk, LE
    Yorkston, J
    Huang, WD
    Sandler, H
    Siewerdsen, JH
    ElMohri, Y
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03): : 661 - 672
  • [2] ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS
    BALTER, JM
    CHEN, GTY
    PELIZZARI, CA
    KRISHNASAMY, S
    RUBIN, S
    VIJAYAKUMAR, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01): : 137 - 143
  • [3] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [4] RADIOTHERAPY PORTAL VERIFICATION - AN OBSERVER STUDY
    BISSETT, R
    BOYKO, S
    LESZCZYNSKI, K
    COSBY, S
    DUNSCOMBE, P
    LIGHTFOOT, N
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (806) : 165 - 174
  • [5] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [6] WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS
    BYHARDT, RW
    COX, JD
    HORNBURG, A
    LIERMANN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10): : 881 - 887
  • [7] QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER
    CREUTZBERG, CL
    ALTHOF, VGM
    HUIZENGA, H
    VISSER, AG
    LEVENDAG, PC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 529 - 539
  • [8] INTERACTIVE USE OF ONLINE PORTAL IMAGING IN PELVIC RADIATION
    DENEVE, W
    VANDENHEUVEL, F
    COGHE, M
    VERELLEN, D
    DEBEUKELEER, M
    ROELSTRAETE, A
    DEROOVER, P
    THON, L
    STORME, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 517 - 524
  • [9] DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY
    EZZ, A
    MUNRO, P
    PORTER, AT
    BATTISTA, J
    JAFFRAY, DA
    FENSTER, A
    OSBORNE, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 159 - 165
  • [10] Preliminary study of a metal/a-Se-based portal detector
    Falco, T
    Wang, H
    Fallone, BG
    [J]. MEDICAL PHYSICS, 1998, 25 (06) : 814 - 823