Retention and stress distribution in distal extension removable partial dentures with and without implant association

被引:21
|
作者
Silveira Rodrigues, Renata Cristina [1 ]
Lapria Faria, Adriana Claudia [1 ]
Macedo, Ana Paula [1 ]
Chiarello de Mattos, Maria da Gloria [1 ]
Ribeiro, Ricardo Faria [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, BR-14040904 Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implantation; Dental prosthesis retention; Denture precision attachments; Removable partial dentures; COMMERCIALLY PURE TITANIUM; WEAR-RESISTANCE; CLASP RETENTION; SUPPORT; FRAMEWORKS; ALLOYS;
D O I
10.1016/j.jpor.2012.07.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR). Methods: Frameworks were cast from cp Ti (n = 18) and Co-Cr alloy (n = 18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (a = 0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD. Results: Retention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co-Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co-Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD. Conclusion: The results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs. (C) 2012 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 38 条
  • [21] Attachment-Retained versus Clasp-Retained Removable Partial Dentures: Effects of Retention on Patient Satisfaction
    Dula, Linda J.
    Kelmendi, Tringa Z.
    Shala, Kujtim
    Staka, Gloria
    Pustina-Krasniqi, Teuta
    Kosumi, Shera
    EUROPEAN JOURNAL OF DENTISTRY, 2024,
  • [22] Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures
    Rungsiyakull, Pimduen
    Kujarearntaworn, Kallaya
    Khongkhunthian, Pathawee
    Swain, Michael
    Rungsiyakull, Chaiy
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [23] Oral function of implant-assisted removable partial dentures with magnetic attachments using short implants: A prospective study
    Watanabe, Masataka
    Kanazawa, Manabu
    Sato, Daisuke
    Uehara, Yoko
    Miyayasu, Anna
    Iwaki, Maiko
    Komagamine, Yuriko
    Naing, Sai Tun
    Katheng, Awutsadaporn
    Kusumoto, Yuriko
    Abe, Yuka
    Baba, Kazuyoshi
    Minakuchi, Shunsuke
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (12) : 1265 - 1272
  • [24] Mechanical Evaluation of Implant-Assisted Removable Partial Dentures in Kennedy Class I Patients: Finite Element Design Considerations
    Messias, Ana
    Neto, Maria A.
    Amaro, Ana M.
    Lopes, Vitor M.
    Nicolau, Pedro
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 18
  • [25] Patient-reported outcomes of implant-assisted removable partial dentures with magnetic attachments using short implants: A prospective study
    Negoro, Masatoshi
    Kanazawa, Manabu
    Sato, Daisuke
    Shimada, Ryo
    Miyayasu, Anna
    Asami, Mari
    Katheng, Awutsadaporn
    Kusumoto, Yuriko
    Abe, Yuka
    Baba, Kazuyoshi
    Minakuchi, Shunsuke
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 554 - 558
  • [26] Evaluation of the Defects of Removable Partial Dentures' (RPD) Frameworks Made in Prosthodontics Department Of Qazvin Dentistry School Regarding Retention, Stability, and Support
    Haddad, Mohammad Amin
    Sajad, Mohammad Ebrahim Moosavi
    Aalaei, Shima
    GALEN MEDICAL JOURNAL, 2014, 3 (01): : 46 - 53
  • [27] Strains Around Abutment Teeth with Different Attachments Used for Implant-Assisted Distal Extension Partial Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Omran, Abdelbaset Omar
    Fouad, Mohammed Mohammed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (01): : 42 - 47
  • [28] Comparison of the prognosis of the remaining teeth between implant-supported fixed prostheses and removable partial dentures in partially edentulous patients: A retrospective study
    Yamada, Ryo
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Iwata, Kai
    Saito, Masayasu
    Yokoyama, Atsuro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 83 - 93
  • [29] Effect of Implant Position and Edentulous Span Length on Stresses Around Implants Assisting Claspless Distal Extension Partial Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Kabil, Ahmed Abd El Ghany
    El Mekawy, Nesreen
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (02) : 100 - 106
  • [30] Stresses Induced by Mesially and Distally Placed Implants to Retain a Mandibular Distal-Extension Removable Partial Overdenture: A Comparative Study
    Hegazy, Salah A. F.
    Elshahawi, Inas M.
    ElMotayam, Hassan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 403 - 407