Retention and stress distribution in distal extension removable partial dentures with and without implant association

被引:21
|
作者
Silveira Rodrigues, Renata Cristina [1 ]
Lapria Faria, Adriana Claudia [1 ]
Macedo, Ana Paula [1 ]
Chiarello de Mattos, Maria da Gloria [1 ]
Ribeiro, Ricardo Faria [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, BR-14040904 Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implantation; Dental prosthesis retention; Denture precision attachments; Removable partial dentures; COMMERCIALLY PURE TITANIUM; WEAR-RESISTANCE; CLASP RETENTION; SUPPORT; FRAMEWORKS; ALLOYS;
D O I
10.1016/j.jpor.2012.07.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR). Methods: Frameworks were cast from cp Ti (n = 18) and Co-Cr alloy (n = 18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (a = 0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD. Results: Retention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co-Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co-Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD. Conclusion: The results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs. (C) 2012 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 38 条
  • [1] Effect of implant support on distal extension removable partial dentures:: in vitro assessment
    Ohkubo, C.
    Kurihara, D.
    Shimpo, H.
    Suzuki, Y.
    Kokubo, Y.
    Hosoi, T.
    JOURNAL OF ORAL REHABILITATION, 2007, 34 (01) : 52 - 56
  • [2] Photoelastic Study of the Support Structures of Distal-Extension Removable Partial Dentures
    Costa, Marcio Magno
    Moreira Rodrigues da Silva, Marco Antonio
    Goulart Oliveira, Sonia Aparecida
    Gomes, Vanderlei Luiz
    Carvalho, Polliane Morais
    Lucas, Barbara Lima
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (07): : 589 - 595
  • [3] Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: Patient satisfaction
    Wismeijer, Daniel
    Tawse-Smith, Andrew
    Payne, Alan G. T.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (01) : 20 - 27
  • [4] In vitro study of the effect of implant position and attachment type on stress distribution of implant-assisted removable partial dentures
    Naing, Sai Tun
    Kanazawa, Manabu
    Hada, Tamaki
    Iwaki, Maiko
    Komagamine, Yuriko
    Miyayasu, Anna
    Uehara, Yoko
    Minakuchi, Shunsuke
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (04) : 1697 - 1703
  • [5] Influence of working side contacts on masticatory function for mandibular distal extension removable partial dentures
    Sueda, S
    Fueki, K
    Sato, S
    Sato, H
    Shiozaki, T
    Kato, M
    Ohyama, T
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (03) : 301 - 306
  • [6] MASTICATION WITH AND WITHOUT REMOVABLE PARTIAL DENTURES - AN INTRAINDIVIDUAL STUDY
    LIEDBERG, B
    SPIECHOWICZ, E
    OWALL, B
    DYSPHAGIA, 1995, 10 (02) : 107 - 112
  • [7] A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment
    Bae, Eun-Bin
    Kim, Seong-Jong
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Huh, Jung-Bo
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [8] Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures
    Toshifumi Nogawa
    Masayasu Saito
    Naomichi Murashima
    Yoshiyuki Takayama
    Atsuro Yokoyama
    International Journal of Implant Dentistry, 6
  • [9] Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures
    Nogawa, Toshifumi
    Saito, Masayasu
    Murashima, Naomichi
    Takayama, Yoshiyuki
    Yokoyama, Atsuro
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [10] Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies
    Ichikawa, Hiromi
    Yoda, Nobuhiro
    Ogawa, Toru
    Iwamoto, Maya
    Kawata, Tetsuo
    Egusa, Hiroshi
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)