Simultaneous determination of amino acids and carbohydrates by anion-exchange chromatography with integrated pulsed amperometric detection

被引:57
作者
Yu, H
Ding, YS
Mou, SF
Jandik, P
Cheng, J
机构
[1] Acad Sinica, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
[2] Dionex Chem Corp, Sunnyvale, CA 94086 USA
[3] Harbin Normal Univ, Dept Chem, Harbin 150080, Peoples R China
关键词
amino acids; carbohydrates;
D O I
10.1016/S0021-9673(02)00739-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A direct, sensitive, simple and practical method for simultaneous determination of amino acids and carbohydrates by anion-exchange chromatography with integrated pulsed amperometric detection was developed. The retention behavior of amino acids and carbohydrates on the anion-exchange column and the detection of amino acids and carbohydrates at different integrated pulsed amperometric detection waveforms were investigated. The optimized gradient eluent conditions for analysis of 17 amino acids and nine carbohydrates were obtained. Separation time was 100 min. Detection limits for amino acids and carbohydrates were 5.2-207.1 nM under injection volume of 25 mul. The RSDs of peak area were 1.2-3.3%. The calibration graphs of peak area for the analytes were linear over about three orders of magnitude with a correlation coefficient of 0.9950-0.9999. The method was applied to determine amino acids and carbohydrates in a liquid condiment with satisfactory results. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 14 条
[1]   An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography [J].
Clarke, AP ;
Jandik, P ;
Rocklin, RD ;
Liu, Y ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2774-2781
[2]  
El Rassi Z, 1999, ELECTROPHORESIS, V20, P3134, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3134::AID-ELPS3134>3.0.CO
[3]  
2-8
[4]   Recent progress in reversed-phase and hydrophobic interaction chromatography of carbohydrate species [J].
ElRassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :93-118
[5]   Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry and their trace detection in complex matrices by gas chromatography-tandem mass spectrometry [J].
Fox, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :287-300
[6]   Analyzing mixtures of amino acids and carbohydrates using bi-modal integrated amperometric detection [J].
Jandik, P ;
Clarke, AP ;
Avdalovic, N ;
Andersen, DC ;
Cacia, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01) :193-201
[7]   New technique for increasing retention of arginine on an anion-exchange column [J].
Jandik, P ;
Cheng, J ;
Jensen, D ;
Manz, S ;
Avdalovic, N .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :38-44
[8]   Simplified in-line sample preparation for amino acid analysis in carbohydrate containing samples [J].
Jandik, P ;
Cheng, J ;
Jensen, D ;
Manz, S ;
Avdalovic, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 758 (02) :189-196
[9]  
Lee JE, 1996, J MICROBIOL BIOTECHN, V6, P137
[10]  
Smith JT, 1999, ELECTROPHORESIS, V20, P3078, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3078::AID-ELPS3078>3.3.CO