Endovascular Stent-graft Management of Aortic Intramural Hematomas

被引:31
|
作者
Monnin-Bares, Valerie [1 ]
Thony, Frederic [1 ]
Rodiere, Mathieu [1 ]
Bach, Vincent [2 ]
Hacini, Rachid [2 ]
Blin, Dominique [2 ]
Ferretti, Gilbert [1 ]
机构
[1] Univ Grenoble 1, Ctr Hosp Univ A Michallon, Dept Radiol, F-38043 Grenoble, France
[2] Univ Grenoble 1, Ctr Hosp Univ A Michallon, Dept Thorac & Cardiovasc Surg, F-38043 Grenoble, France
关键词
DESCENDING THORACIC AORTA; PENETRATING ATHEROSCLEROTIC ULCERS; DIFFERENT CLINICAL-FEATURES; COMPUTED-TOMOGRAPHY; PREDICTIVE FACTORS; NATURAL-HISTORY; FOLLOW-UP; REPAIR; DISSECTION; COMPLICATIONS;
D O I
10.1016/j.jvir.2009.02.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To report initial experience with endovascular stent-grafting in aortic intramural hematoma (IMH) MATERIALS AND METHODS: From 2000 to 2006, 15 patients (mean age, 67 years; range, 54-83 y) underwent endovascular treatment of aortic IMH. Thirteen patients were admitted for acute aortic syndrome and two for traumatic aortic injury. An endovascular procedure was performed as primary treatment for four patients (type A IMH, n = 3; type B IMH, n = 1) and as a second-line therapy in 11 patients because of unfavorable evolution (type A IMH, n = 1; type B IMH, n = 10). All stent-grafts were placed in the descending aorta, even for type A IMH. The mean follow-up was 21 months (range, 6-72 months). RESULTS: The primary success rate was 93%, with complete exclusion of the lesion (n = 14). Exclusion was partial for one patient with a type I endoleak (7%). The 30-day mortality rate was zero. IMH evolution was favorable in all cases, with decreased aortic wall thickening (n = 8) or complete regression (n = 7). Complications associated with endovascular repair were mainly related to aneurysm formation (20%). The late death rate was 7%. CONCLUSIONS: Endovascular stent-graft treatment can be performed in the management of complicated IMH, even in some cases of type A IMH, when an intimal lesion is located in the isthmus or descending aorta with contraindications to surgery. This procedure offers low morbidity and mortality rates, representing a feasible therapeutic option especially for elderly patients with comorbidities. Further studies are necessary to confirm these preliminary results.
引用
收藏
页码:713 / 721
页数:9
相关论文
共 50 条
  • [41] Aortic Remodeling in Type B Aortic Dissection: Effects of Endovascular Stent-Graft Repair and Medical Treatment on True and False Lumen Volumes
    Huptas, Sebastian
    Mehta, Rajendra H.
    Kuehl, Hilmar
    Tsagakis, Konstantinos
    Reinsch, Nico
    Kahlert, Philipp
    Jakob, Heinz G.
    Erbel, Raimund
    Eggebrecht, Holger
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (01) : 28 - 38
  • [42] Technical Assessment of the Preloaded Fenestrated Stent-Graft in the Management of Pararenal Aortic Aneurysms
    Bisdas, Theodosios
    Donas, Konstantinos P.
    Torsello, Giovanni
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 461 - 468
  • [43] Comparison of a percutaneous separate stent endograft and a conventional thoracic stent-graft for endovascular repair of type B aortic dissection
    Park, S
    Min, PK
    Joung, B
    Ko, YG
    Choi, D
    Jang, Y
    Lee, DY
    Chang, BC
    Shim, WH
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (04) : 378 - 384
  • [44] Back-Table Modified Stent-Graft for Endovascular Repair of Ascending Aorta
    Shi, Juan
    Liu, Ligang
    Wei, Xiang
    Ma, Mingjia
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (06) : 888 - 896
  • [45] Descending thoracic aortic diseases: Stent-graft repair
    Fattori, R
    Napoli, G
    Lovato, L
    Grazia, C
    Piva, T
    Rocchi, G
    Angeli, E
    Di Bartolomeo, R
    Gavelli, G
    RADIOLOGY, 2003, 229 (01) : 176 - 183
  • [46] The contemporary design of endovascular aneurysm stent-graft materials: PTFE versus polyester
    Hynes, Niamh
    Acharya, Yogesh
    Sultan, Sherif
    FRONTIERS IN SURGERY, 2022, 9
  • [47] Penetrating atherosclerotic ulcer of the aorta: treatment by endovascular stent-graft
    Eggebrecht, H
    Baumgart, D
    Schmermund, A
    Herold, U
    Hunold, P
    Jakob, H
    Erbel, R
    CURRENT OPINION IN CARDIOLOGY, 2003, 18 (06) : 431 - 435
  • [48] Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance
    Giannoni, MF
    Palombo, G
    Sbarigia, E
    Speziale, F
    Zaccaria, A
    Fiorani, P
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (02) : 208 - 217
  • [49] Outcomes of Endovascular Aneurysm Repair Using the Anaconda Stent-Graft
    Tigkiropoulos, Konstantinos
    Stavridis, Kyriakos
    Lazaridis, Ioannis
    Bontinis, Evangelos
    Zournatzi, Ioulia
    Kolaki, Nikoletta
    Karamanos, Dimitrios
    Saratzis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (03) : 462 - 467
  • [50] Is Endovascular Stent-Graft Treatment of Primary Aortoesophageal Fistula Worthwhile?
    Malas, Mahmoud B.
    Saha, Surajit
    Qazi, Umair
    Duncan, Mark
    Perler, Bruce A.
    Freischlag, Julie A.
    Veith, Frank J.
    VASCULAR AND ENDOVASCULAR SURGERY, 2011, 45 (01) : 83 - 89