Effect of Temperature on performance of 3He Filled Neutron Proportional Counters

被引:1
|
作者
Desai, Shraddha S. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Solid State Phys, Bombay 400085, Maharashtra, India
关键词
neutron detectors; thermal expansion; Thermal neutron cross section;
D O I
10.1063/1.4872713
中图分类号
O59 [应用物理学];
学科分类号
摘要
Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with 3 He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with 3 He and stopping gases Kr and CF4. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.
引用
收藏
页码:668 / 670
页数:3
相关论文
共 50 条
  • [31] New application of 3He and 10BF3 proportional counters in a polythene moderator
    Pszona, S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 402 (01): : 139 - 142
  • [32] On studies of 3He and isobutane mixture as neutron proportional counter gas
    Desai, SS
    Shaikh, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 557 (02): : 607 - 614
  • [33] Response matrix of a multisphere neutron spectrometer with an 3He proportional counter
    Vega-Carrillo, HR
    Manzanares-Acuña, E
    Hernández-Dávila, VM
    Sánchez, GAM
    REVISTA MEXICANA DE FISICA, 2005, 51 (01) : 47 - 52
  • [34] Neutron sensitivity and detection efficiency of 3He and 10BF3 counters
    A. Kh. Khokonov
    Yu. V. Savoiskii
    A. V. Kamarzaev
    Physics of Atomic Nuclei, 2010, 73 : 1482 - 1486
  • [35] Neutron sensitivity and detection efficiency of 3He and 10BF3 counters
    Khokonov, A. Kh.
    Savoiskii, Yu. V.
    Kamarzaev, A. V.
    PHYSICS OF ATOMIC NUCLEI, 2010, 73 (09) : 1482 - 1486
  • [36] Verification of He-3 proportional counters' fast neutron sensitivity through a comparison with He-4 detectors: He-3 and He-4 proportional counters' fast neutron sensitivity and evaluation of the cosmic neutron fluxes at ESS
    Piscitelli, Francesco
    Mauri, Giacomo
    Laloni, Alessio
    Hall-Wilton, Richard
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (07):
  • [37] Verification of He-3 proportional counters’ fast neutron sensitivity through a comparison with He-4 detectorsHe-3 and He-4 proportional counters’ fast neutron sensitivity and evaluation of the cosmic neutron fluxes at ESS
    Francesco Piscitelli
    Giacomo Mauri
    Alessio Laloni
    Richard Hall-Wilton
    The European Physical Journal Plus, 135
  • [38] High-voltage microdischarge in ultra-low background 3He proportional counters
    Heeger, KM
    Elliott, SR
    Robertson, RGH
    Smith, MWE
    Steiger, TD
    Wilkerson, JF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1829 - 1833
  • [39] A novel method to measure low flux ambient thermal neutrons with 3He proportional counters
    Zeng, Z. M.
    Gong, H.
    Yue, Q.
    Li, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 866 : 242 - 247
  • [40] COMPACT NEUTRON DETECTOR OF A BATTERY FORM FROM PROPORTIONAL HE-3-COUNTERS
    BEMER, B
    VANKOV, AA
    GRIGOREV, YV
    DITTSE, K
    KEPERNIK, K
    KONYUSHKOV, AG
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (06): : 57 - 59