The high energy X-ray timing experiment on XTE

被引:0
|
作者
Gruber, DE [1 ]
Blanco, PR [1 ]
Heindl, WA [1 ]
Pelling, MR [1 ]
Rothschild, RE [1 ]
Hink, PL [1 ]
机构
[1] WASHINGTON UNIV,DEPT PHYS,ST LOUIS,MO 63130
来源
ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES | 1996年 / 120卷 / 04期
关键词
space vehicles; instrumentation; detectors; miscellaneous;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The High Energy X-ray Timing Experiment (HEXTE) is one of three science instruments of NASA's X-ray Timing Explorer (XTE) mission, which was launched into low earth orbit in late 1995. Its energy range of 15-250 keV overlaps with the OSSE and BATSE detectors of the Compton Gamma Ray Observatory (CGRO). The HEXTE consists of eight NaI scintillation detectors grouped into two independent clusters, each with its own data processing electronics. State-of-the art detector resolution is achieved with the help of an automatic gain control system. Like OSSE, the HEXTE permits on-the-fly correction of internal background by beam-switching to blank fields adjacent to the source on the sky. We present here a description of the HEXTE, and demonstrate some aspects of its performance by a spectral simulation of a bright Galactic source with cyclotron absorption. While the HEXTE's large collecting area yields the high event rates essential for temporal studies, the sensitivity to faint sources (such as active galaxies) is limited by systematic effects in the residual background, which we discuss in some detail.
引用
收藏
页码:C641 / C644
页数:4
相关论文
共 50 条
  • [21] First ptychographic X-ray computed tomography experiment on the NanoMAX beamline
    Kahnt, Maik
    Sala, Simone
    Johansson, Ulf
    Bjorling, Alexander
    Jiang, Zhimin
    Kalbfleisch, Sebastian
    Lenrick, Filip
    Pikul, James H.
    Thanell, Karina
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2020, 53 : 1444 - 1451
  • [22] New Science Case for the Micro-X High Energy Resolution Microcalorimeter X-ray Imaging Rocket
    Figueroa-Feliciano, E.
    Adams, J. S.
    Baker, R.
    Bandler, S. R.
    DeLaney, T. A.
    Dewey, D.
    Doriese, W. B.
    Eckart, M. E.
    Galeazzi, M.
    Goeke, R.
    Hamersma, R.
    Hilton, G. C.
    Hwang, U.
    Irwin, K. D.
    Kelley, R. L.
    Kilbourne, C. A.
    Leman, S. W.
    McCammon, D.
    Okajima, T.
    Porter, F. S.
    Reintsema, C. D.
    Rutherford, J. M.
    Saab, T.
    Serlemitsos, P.
    Soong, Y.
    Trowbridge, S. N.
    Wikus, P.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 426 - +
  • [23] High spectral and spatial resolution X-ray transmission radiography and tomography using a Color X-ray Camera
    Boone, Matthieu N.
    Garrevoet, Jan
    Tack, Pieter
    Scharf, Oliver
    Cormode, David P.
    Van Loo, Denis
    Pauwels, Elin
    Dierick, Manuel
    Vincze, Laszlo
    Van Hoorebeke, Luc
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 644 - 648
  • [24] An X-ray all-sky monitor with extraordinary sensitivity
    Priedhorsky, WC
    Peele, AG
    Nugent, KA
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1996, 279 (03) : 733 - &
  • [25] The medium-energy concentrator spectrometer on board the BeppoSAX X-ray astronomy satellite
    Boella, G
    Chiappetti, L
    Conti, G
    Cusumano, G
    DelSordo, S
    LaRosa, G
    Maccarone, MC
    Mineo, T
    Molendi, S
    Re, S
    Sacco, B
    Tripiciano, M
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1997, 122 (02): : 327 - 340
  • [26] Elemental composition x-ray fluorescence analysis with a TES-based high-resolution x-ray spectrometer
    Wu, Bingjun
    Xia, Jingkai
    Zhang, Shuo
    Fu, Qiang
    Zhang, Hui
    Xie, Xiaoming
    Liu, Zhi
    CHINESE PHYSICS B, 2023, 32 (09)
  • [27] Characterization of X-ray Detectors in the MIT X-ray Polarimetry Beamline
    Heine, Sarah N. T.
    Marshall, Herman L.
    Schneider, Benjamin
    LaMarr, Beverly
    Kothnur, Nithya
    Garner, Alan
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [28] Simulations and measurements of the background encountered by a high-altitude balloon-borne experiment for hard X-ray astronomy
    Lum, KSK
    Mohr, JJ
    Barret, D
    Grindlay, JE
    Manandhar, RP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 396 (03): : 350 - 359
  • [29] The low-energy concentrator spectrometer on-board the BeppoSAX X-ray astronomy satellite
    Parmar, AN
    Martin, DDE
    Bavdaz, M
    Favata, F
    Kuulkers, E
    Vacanti, G
    Lammers, U
    Peacock, A
    Taylor, BG
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1997, 122 (02): : 309 - 326
  • [30] A laboratory X-ray microbeam for combined X-ray diffraction and fluorescence measurements
    Rouziere, S.
    Jourdanneau, E.
    Kasmi, B.
    Joly, P.
    Petermann, D.
    Albouy, P. A.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2010, 43 : 1131 - 1133