Leak detection in branched pipe systems coupling wavelet analysis and a Lagrangian model

被引:85
作者
Ferrante, Marco [1 ]
Brunone, Bruno [1 ]
Meniconi, Silvia [1 ]
机构
[1] Univ Perugia, Dipartimento Ingn Civile & Ambientale, I-06125 Perugia, Italy
来源
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA | 2009年 / 58卷 / 02期
关键词
leak detection; pressurized pipes; water hammer; wavelets; UNSTEADY-STATE TESTS; PRESSURE; DIAGNOSIS; NETWORKS; SIGNALS;
D O I
10.2166/aqua.2009.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Transient analysis of pressurized pipe systems yields useful information regarding the actual state in an effective and rapid manner and then it can be used for the diagnosis of the system. Besides the framework of the inverse problem solution, transient based leak detection can also focus on the modalities with which pressure waves generated by a known manoeuvre travel through a system. This latter approach has been successfully applied by several authors to simple systems, usually comprising a single pipe with a constant head reservoir and a valve at the end section. The present work extends this approach to more complex systems, that is, those with at least one junction. To accomplish this, the pressure signal is analysed using wavelet analysis, a technique which has produced encouraging results. Moreover, the analysis of the pressure signals is generalized by means of a Lagrangian model, which directly simulates the pressure waves' generations and movements in the system. Coupling wavelet analysis with the Lagrangian model allows us to associate singularities pointed out in pressure signals to singularities in the system. In order to better ascertain the applicability of the method, tests were carried out on both a laboratory installation and a real system.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 22 条
[1]   Pressure waves as a tool for leak detection in closed conduits [J].
Brunone, B. ;
Ferrante, M. .
URBAN WATER JOURNAL, 2004, 1 (02) :145-155
[2]   Transient test-based technique for leak detection in outfall pipes [J].
Brunone, B .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1999, 125 (05) :302-306
[3]   Detecting leaks in pressurised pipes by means of transients [J].
Brunone, B ;
Ferrante, M .
JOURNAL OF HYDRAULIC RESEARCH, 2001, 39 (05) :539-547
[4]  
BRUNONE B, 1989, TECNICA VERIFICA INT, pD222
[5]  
Brunone B, 2008, J AM WATER WORKS ASS, V100, P108
[6]  
Covas D, 2000, BHR GR CONF SER PUBL, P169
[7]   DE-NOISING BY SOFT-THRESHOLDING [J].
DONOHO, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1995, 41 (03) :613-627
[8]   Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis [J].
Ferrante, M ;
Brunone, B .
ADVANCES IN WATER RESOURCES, 2003, 26 (01) :95-105
[9]   Pipe system diagnosis and leak detection by unsteady-state tests. 2. Wavelet analysis [J].
Ferrante, M ;
Brunone, B .
ADVANCES IN WATER RESOURCES, 2003, 26 (01) :107-116
[10]   Wavelets for the analysis of transient pressure signals for leak detection [J].
Ferrante, Marco ;
Brunone, Bruno ;
Meniconi, Silvia .
JOURNAL OF HYDRAULIC ENGINEERING, 2007, 133 (11) :1274-1282