An efficient X-ray radiography image analysis algorithm is developed for defect detection in submerged arc welding and segmentation. The raw X-ray image is pre-processed to remove impulsive noise, enhance greyscale contrast and segment the regions of interest (ROI) where the welding images are located. A density-based spatial clustering method is then applied to detect and segment suspicious defect regions (SDRs) within the ROIs. These SDRs will then be normalised in size. An important assumption is that since the shapes of the SDRs are rather similar, a given SDR may be represented by a linear combination of very few model SDRs. In other words, if a dictionary of model defect images and noise images is provided, a given defect should then be better represented by the linear combination of true defect images rather than noisy images. A sparse vector representation is thus sought by performing l(0), l(1), and l(2) norm minimisation. Finally, the sparse representations of the defect part and noisy part are compared in the context of a maximum likelihood ratio test, which leads to the final classification. Tested with 400 X-ray radiographic images obtained from a factory production line, the proposed algorithm achieves a sensitivity of 99% (198/200) and a specificity of 98% (196/200). Compared to previously reported radiographic image analysis algorithms, the proposed algorithm is robust, efficient and readily applicable to real-world applications.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 45 条
  • [41] Real-time CBCT imaging and motion tracking via a single arbitrarily-angled x-ray projection by a joint dynamic reconstruction and motion estimation (DREME) framework
    Shao, Hua-Chieh
    Mengke, Tielige
    Pan, Tinsu
    Zhang, You
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (02)
  • [42] DETECTION OF XANTHOMONAS CITRI subsp CITRI A☆, AW AND X-FUSCANS subsp AURANTIFOLII B, C USING PCR AND REAL-TIME PCR
    Yu, S. M.
    Ramkumar, G.
    Lee, Y. H.
    JOURNAL OF PLANT PATHOLOGY, 2017, 99 (02) : 461 - +
  • [43] Time-Resolved Quantitative Analysis of the Diaphragms During Tidal Breathing in a Standing Position Using Dynamic Chest Radiography with a Flat Panel Detector System ("Dynamic X-Ray Phrenicography"): Initial Experience in 172 Volunteers
    Yamada, Yoshitake
    Ueyama, Masako
    Abe, Takehiko
    Araki, Tetsuro
    Abe, Takayuki
    Nishino, Mizuki
    Jinzaki, Masahiro
    Hatabu, Hiroto
    Kudoh, Shoji
    ACADEMIC RADIOLOGY, 2017, 24 (04) : 393 - 400
  • [44] Sub-10 nm Lanthanide-Doped Lu6O5F8 Nanoscintillators for Real-Time High-Resolution Dynamic 3D X-Ray Imaging
    Zou, Huirong
    Zhu, Wenjuan
    Zhao, Jingtao
    Zhou, Su
    Xu, Shiqing
    Lei, Lei
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (49)
  • [45] Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: Time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system ("dynamic X-ray phrenicography")
    Yamada, Yoshitake
    Ueyama, Masako
    Abe, Takehiko
    Araki, Tetsuro
    Abe, Takayuki
    Nishino, Mizuki
    Jinzaki, Masahiro
    Hatabu, Hiroto
    Kudoh, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 76 - 82