A Case of False-Positive Test Results in a Pregnant Woman of Unknown HIV Status at Delivery

被引:5
|
作者
Akl, Pascale [1 ]
Blick, Kenneth E. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Pathol, Oklahoma City, OK 73104 USA
来源
LABMEDICINE | 2014年 / 45卷 / 03期
关键词
HIV; test interference; microclots; immunoassay; VIRUS SCREENING ASSAY; MULTICENTER EVALUATION; IMMUNODEFICIENCY; ANTIGEN; SEROCONVERSION; TRANSMISSION; INFECTION; REDUCTION;
D O I
10.1309/LMAAGVXK05LUWOQN
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We report a case of a false-positive HIV result in an apparently healthy pregnant woman. Since no prenatal HIV testing had been performed, we screened for HIV reactivity utilizing the Architect HIV-Ag/Ab Combo assay. Results obtained were inconsistent in that they were repeatedly HIV reactive on a single serum sample while nonreactive on a plasma sample. However, both sample types were nonreactive on the Advia Centaur HIV-1/0/2 and Oraquick assays. For further confirmation, an HIV-1 Western blot and viral load were performed; blot results were indeterminate while the viral load was undetectable. We concluded that the repeatedly reactive serum serology results were false-positive. While the cause of this false reactivity is not clear, most likely fibrin microdots in the serum sample interfered with the assay and thus accounted for the false positivity. Plasma may thus provide a more appropriate sample type when using the Architect assay, especially when testing pregnant women.
引用
收藏
页码:259 / 263
页数:5
相关论文
共 50 条
  • [41] Healthcare Worker with "Pertussis": Consequences of a False-Positive Polymerase Chain Reaction Test Result
    Weber, David J.
    Miller, Melissa B.
    Brooks, Rebecca H.
    Brown, Vickie M.
    Rutala, William A.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (03) : 306 - 307
  • [42] Case report: A pediatric case of repeated false-positive urea breath test for Helicobacter pylori without decreased gastric acid secretion
    Nishino, Masafumi
    Kakiuchi, Toshihiko
    Fukuda, Kayoko
    Yoshiura, Masato
    FRONTIERS IN MEDICINE, 2023, 10
  • [43] HIV Status Discordance: Associated Factors Among HIV Positive Pregnant Women in Lagos, Southwest Nigeria
    Ujah, Innocent A. O.
    Ezechi, Oliver C.
    Ohihoin, Aigbe Gregory
    AFRICAN JOURNAL OF REPRODUCTIVE HEALTH, 2015, 19 (02): : 108 - 116
  • [44] Blood screening for human immunodeficiency virus: a new algorithm to reduce the false-positive results
    Zhang, R.
    Sun, Y.
    Wang, L.
    Zhang, K.
    Xie, J.
    Li, J.
    TRANSFUSION MEDICINE, 2013, 23 (04) : 260 - 264
  • [45] False-Positive Serum Cocaine Screening Results in Patients Undergoing Evaluation for Renal Transplant
    Snozek, Christine L. H.
    Corey, Rebecca L.
    Buras, Matthew R.
    Johnson-Davis, Kamisha L.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (07) : 587 - 590
  • [46] Piperacillin/tazobactam (Tazocin™) seems to be no longer responsible for false-positive results of the galactomannan assay
    Mikulska, M.
    Furfaro, E.
    Del Bono, V.
    Raiola, A. M.
    Ratto, S.
    Bacigalupo, A.
    Viscoli, C.
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2012, 67 (07) : 1746 - 1748
  • [47] Avoiding False-Positive SARS-CoV-2 Rapid Antigen Test Results with Point-of-Care Molecular Testing on Residual Test Buffer
    LeBlanc, Jason J.
    McCracken, Gregory R.
    Goodall, Barbara
    Hatchette, Todd F.
    Barrett, Lisa
    Ross, John
    Davidson, Ross J.
    Patriquin, Glenn
    MICROBIOLOGY SPECTRUM, 2022, 10 (04):
  • [48] Correlation between rapid HIV testing and fourth-generation ELISA results for HIV detection among pregnant patients in the delivery room
    Almaguer, Alejandro G.
    Mendoza-Flores, Lidia
    Sanchez-Lopez, Luis A.
    Palau-Davila, Laura A.
    Padilla-Orozco, Magaly
    Camacho-Ortiz, Adrian
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2017, 137 (01) : 31 - 33
  • [49] Modelling the probability and impact of false-positive serology forBorrelia burgdorferisensu lato: A case study
    Houben, Rosa M. A. C.
    Meersschaert, Carole
    Hendrickx, Guy
    Pitel, Pierre-Hugues
    Amory, Helene
    EQUINE VETERINARY JOURNAL, 2021, 53 (01) : 71 - 77
  • [50] False-positive results corrected by the use of heterophilic antibody-blocking reagent in thyroglobulin immunoassays
    Massart, Catherine
    Corcuff, Jean-Benoit
    Bordenave, Laurence
    CLINICA CHIMICA ACTA, 2008, 388 (1-2) : 211 - 213