BIO-IMPEDANCE MEASUREMENT ALLOWS DISPLAYING THE EARLY STAGES OF NEUTROPHIL EXTRACELLULAR TRAPS

被引:9
|
作者
Linnemann, Caren [1 ]
Venturelli, Sascha [2 ,3 ]
Konrad, Franziska [4 ]
Nussler, Andreas K. [1 ]
Ehnert, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Siegfried Weller Inst Trauma Res, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Inst Physiol, Dept Vegetat & Clin Physiol, Tubingen, Germany
[3] Univ Hohenheim, Inst Nutr Sci, Dept Nutr Biochem, Stuttgart, Germany
[4] Univ Hosp Tuebingen, Dept Anesthesiol & Intens Care Med, Tubingen, Germany
来源
EXCLI JOURNAL | 2020年 / 19卷
关键词
Bio-impedance; neutrophils; neutrophil extracellular traps; Sytox Green Assay; xCelligence; immune cell activation; NADPH OXIDASE; DYNAMICS; VIABILITY; PROMOTE; ASSAY;
D O I
10.17179/excli2020-2868
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Neutrophils are the most abundant immune cells in the blood. Besides common immune defense mechanisms, releasing their DNA covered with antimicrobial proteases and histones represent another strong defense mechanism: neutrophil extracellular traps. In vitro the two most common inducers of these, so called, NETs are calcium ionophores (CI) and PMA (Phorbol 12-myristate 13-acetate). Following stimulation monitoring of NET release is necessary. For now, the methods of choice are quantification of free DNA by fluorescent dyes or analysis of immunofluorescence images. As a new method we tested bio-impedance monitoring of neutrophils after stimulation with the two inducers PMA and CI in gold-electrode coated plates. Bio-impedance (cell index) was measured over time. Results were compared to the monitoring of NETs by the fluorescent DNA-binding dye Sytox Green and immunofluorescence analysis. Cell index peaked about 25 min faster following CI stimulation than following PMA stimulation. The activation in Sytox Green Assay was significantly later detectable for PMA (+ approx. 90 min) but not for CI stimulation. The earlier and faster activation by CI was also confirmed by immunofluorescence staining Our data suggest that bio-impedance measurement allows an easy online tracking of early neutrophil activation. This offers new opportunities to monitor early phases and stimuli-dependent dynamics of NETosis.
引用
收藏
页码:1481 / 1495
页数:15
相关论文
共 50 条
  • [41] Mixing frequency bio-impedance measurement technology based on DFT and virtual reference vector
    Wang Chao
    Huang Chunyan
    Zhang Xiaoli
    Wang Huaxiang
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 455 - +
  • [42] 3′-Nucleotidase/Nuclease Activity Allows Leishmania Parasites To Escape Killing by Neutrophil Extracellular Traps
    Guimaraes-Costa, Anderson B.
    DeSouza-Vieira, Thiago S.
    Paletta-Silva, Rafael
    Freitas-Mesquita, Anita Leocadio
    Meyer-Fernandes, Jose Roberto
    Saraiva, Elvira M.
    INFECTION AND IMMUNITY, 2014, 82 (04) : 1732 - 1740
  • [43] Error Correction Algorithm for High Accuracy Bio-Impedance Measurement in Wearable Healthcare Applications
    Kubendran, Rajkumar
    Lee, Seulki
    Mitra, Srinjoy
    Yazicioglu, Refet Firat
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (02) : 196 - 205
  • [44] Predicting burst pressure of radiofrequency-induced colorectal anastomosis by bio-impedance measurement
    Zhao, Lingxi
    Zhou, Yu
    Song, Chengli
    Wang, Zhigang
    Cuschieri, Alfred
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (03) : 489 - 500
  • [45] Error Correction Algorithm for High Accuracy Bio-impedance Measurement in Wearable Healthcare Applications
    Kubendran, Rajkumar Chinnakonda
    Lee, Seulki
    Mitra, Srinjoy
    Yazicioglu, Refet Firat
    2013 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2013, : 1292 - 1295
  • [46] Digitally controlled reference impedance device for test and calibration of the bio-impedance measurement system (BIMS) in a networked environment
    Birjukov, A.
    Krivoshei, A.
    Parve, T.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 276 - 279
  • [47] PLASMA MYELOPEROXIDASE- AND NEUTROPHIL ELASTASE-DNA ASSAY FOR MEASUREMENT OF NEUTROPHIL EXTRACELLULAR TRAPS
    Huq, M. A.
    Tomino, A.
    Hashiba, M.
    Ando, M.
    Gocho, T.
    Miyabe, H.
    Kano, H.
    Tsuda, M.
    Hattori, T.
    Hirakawa, A.
    Takeyama, N.
    SHOCK, 2015, 43 (06): : 55 - 56
  • [48] Analysis of Bio-impedance Measurement Method via Electromagnetic Induction Using Probe-coil
    Wang, Chao
    Xu, Chuanjin
    Zhang, Ming
    Yin, Wuliang
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 508 - 511
  • [49] Does bio-impedance spectroscopy allow a precise measurement of hydric compartments of patients in intensive care?
    Champion, S.
    Dewitte, A.
    Carles, P.
    Joannes-Boyau, O.
    Megret, F.
    Fleureau, C.
    Ouattara, A.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A391 - A391
  • [50] Computer-Simulation of Impedance Vector Dynamics of Intra-cardiac 4-electrode Bio-impedance Measurement
    Gordon, Rauno
    Ratsep, Indrek
    Kink, Andres
    BEC 2008: 2008 INTERNATIONAL BIENNIAL BALTIC ELECTRONICS CONFERENCE, PROCEEDINGS, 2008, : 257 - 260