Inverse planning for interstitial gynecologic template brachytherapy: Truly anatomy-based planning

被引:72
作者
Lessard, E [1 ]
Hsu, IC [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 54卷 / 04期
关键词
brachytherapy; gynecologic; inverse planning; simulated annealing; IPSA;
D O I
10.1016/S0360-3016(02)03802-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Commercially available optimization schemes generally result in an undesirable dose distribution, because of the particular shapes of tumors extending laterally from the tandem. Dose distribution is therefore manually obtained by adjusting relative dwell time values until an acceptable solution is found. The objective of this work is to present the clinical application of an inverse planning dose optimization tool for the automatic determination of source dwell time values in the treatment of interstitial gynecologic templates. Methods and Materials: In cases where the tumor extends beyond the range of the tandem-ovoid applicator, catheters as well as the tandem are inserted into the paravaginal and parametrial region in an attempt to cover the tumor volume. CT scans of these patients are then used for CT-based dose planning. Dose distribution is obtained manually by varying the relative dwell times until adequate dose coverage is achieved. This manual planning is performed by an experienced physician. In parallel, our in-house inverse planning based on simulated annealing is used to automatically determine which of all possible dwell positions will become active and to calculate the dwell time values needed to fulfill dose constraints applied to the tumor volume and to each organ at risk. To compare the results of these planning methods, dose-volume histograms and isodose distributions were generated for the target and each organ at risk. Results: This procedure has been applied for the dose planning of 12 consecutive interstitial gynecologic templates cases. For all cases, once the anatomy was contoured, the routine of inverse planning based on simulated annealing found the solution to the dose constraints within 1 min of CPU time. In comparison, manual planning took more than 45 min. The inverse planning-generated plans showed improved protection to organs at risk for the same coverage compared to manual planning. Conclusion: This inverse planning tool reduced the planning time significantly and produced improved plans with reduced dose to the organs at risk. Furthermore, the inverse planning approach improves the physician's control over treatment. The focus becomes the physician's prescription to the target and his or her compromise due to dose to normal structures. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1243 / 1251
页数:9
相关论文
共 21 条
  • [11] KIRKPATRICK S, 1983, SCIENCE, V220, P4598
  • [12] LACHANCE B, 2001, 43 AAPM ANN M SALT L
  • [13] Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function
    Lessard, E
    Pouliot, J
    [J]. MEDICAL PHYSICS, 2001, 28 (05) : 773 - 779
  • [14] COMBINATION OF EXTERNAL BEAM IRRADIATION AND MULTIPLE-SITE PERINEAL APPLICATOR (MUPIT) FOR TREATMENT OF LOCALLY ADVANCED OR RECURRENT PROSTATIC, ANORECTAL, AND GYNECOLOGIC MALIGNANCIES
    MARTINEZ, A
    EDMUNDSON, GK
    COX, RS
    GUNDERSON, LL
    HOWES, AE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (02): : 391 - 398
  • [15] A MULTIPLE-SITE PERINEAL APPLICATOR (MUPIT) FOR TREATMENT OF PROSTATIC, ANORECTAL, AND GYNECOLOGIC MALIGNANCIES
    MARTINEZ, A
    COX, RS
    EDMUNDSON, GK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (02): : 297 - 305
  • [16] INTERSTITIAL THERAPY OF PERINEAL AND GYNECOLOGICAL MALIGNANCIES
    MARTINEZ, A
    HERSTEIN, P
    PORTNUFF, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (03): : 409 - 416
  • [17] The use of fluoroscopy to guide needle placement in interstitial gynecological brachytherapy
    Nag, S
    Martinez-Monge, R
    Ellis, R
    Lewandowski, G
    Vacarello, L
    Boutselis, JG
    Copeland, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02): : 415 - 420
  • [18] Optimization of permanent I-125 prostate implants using fast simulated annealing
    Pouliot, J
    Tremblay, D
    Roy, J
    Filice, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03): : 711 - 720
  • [19] Laparoscopic-assisted application of interstitial brachytherapy for locally advanced cervical carcinoma: Results of a pilot study
    Recio, FO
    Piver, MS
    Hempling, RE
    Eltabbakh, GH
    Hahn, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02): : 411 - 414
  • [20] A new technique for performing Syed-Neblett template interstitial implants for gynecologic malignancies using transrectal-ultrasound guidance
    Stock, RG
    Chan, K
    Terk, M
    Dewyngaert, JK
    Stone, NN
    Dottino, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (04): : 819 - 825