Inverse planning for interstitial gynecologic template brachytherapy: Truly anatomy-based planning

被引:72
作者
Lessard, E [1 ]
Hsu, IC [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 54卷 / 04期
关键词
brachytherapy; gynecologic; inverse planning; simulated annealing; IPSA;
D O I
10.1016/S0360-3016(02)03802-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Commercially available optimization schemes generally result in an undesirable dose distribution, because of the particular shapes of tumors extending laterally from the tandem. Dose distribution is therefore manually obtained by adjusting relative dwell time values until an acceptable solution is found. The objective of this work is to present the clinical application of an inverse planning dose optimization tool for the automatic determination of source dwell time values in the treatment of interstitial gynecologic templates. Methods and Materials: In cases where the tumor extends beyond the range of the tandem-ovoid applicator, catheters as well as the tandem are inserted into the paravaginal and parametrial region in an attempt to cover the tumor volume. CT scans of these patients are then used for CT-based dose planning. Dose distribution is obtained manually by varying the relative dwell times until adequate dose coverage is achieved. This manual planning is performed by an experienced physician. In parallel, our in-house inverse planning based on simulated annealing is used to automatically determine which of all possible dwell positions will become active and to calculate the dwell time values needed to fulfill dose constraints applied to the tumor volume and to each organ at risk. To compare the results of these planning methods, dose-volume histograms and isodose distributions were generated for the target and each organ at risk. Results: This procedure has been applied for the dose planning of 12 consecutive interstitial gynecologic templates cases. For all cases, once the anatomy was contoured, the routine of inverse planning based on simulated annealing found the solution to the dose constraints within 1 min of CPU time. In comparison, manual planning took more than 45 min. The inverse planning-generated plans showed improved protection to organs at risk for the same coverage compared to manual planning. Conclusion: This inverse planning tool reduced the planning time significantly and produced improved plans with reduced dose to the organs at risk. Furthermore, the inverse planning approach improves the physician's control over treatment. The focus becomes the physician's prescription to the target and his or her compromise due to dose to normal structures. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1243 / 1251
页数:9
相关论文
共 21 条
  • [1] THE SYED-NEBLETT INTERSTITIAL TEMPLATE IN LOCALLY ADVANCED GYNECOLOGICAL MALIGNANCIES
    AMPUERO, F
    DOSS, LL
    KHAN, M
    SKIPPER, B
    HILGERS, RD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (12): : 1897 - 1903
  • [2] INTERSTITIAL PARAMETRIAL IMPLANTS IN CARCINOMA OF THE CERVIX STAGE-II-B
    ARISTIZABAL, SA
    WOOLFITT, B
    VALENCIA, A
    OCAMPO, G
    SURWIT, EA
    SIM, D
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (03): : 445 - 450
  • [3] TREATMENT OF ADVANCED CANCER OF THE CERVIX WITH TRANSPERINEAL INTERSTITIAL IRRADIATION
    ARISTIZABAL, SA
    SURWIT, EA
    HEVEZI, JM
    HEUSINKVELD, RS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (07): : 1013 - 1017
  • [4] Outcome of treatment of upper third vaginal recurrences of cervical and endometrial carcinomas with interstitial brachytherapy
    Charra, C
    Roy, P
    Coquard, R
    Romestaing, P
    Ardiet, JM
    Gerard, JP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02): : 421 - 426
  • [5] High dose rate transperineal interstitial brachytherapy for cervical cancer: High pelvic control and low complication rates
    Demanes, DJ
    Rodriguez, RR
    Bendre, DD
    Ewing, TL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (01): : 105 - 112
  • [6] Customized gynecologic interstitial implants: CT-based planning, dose evaluation, and optimization aided by laparotomy
    Eisbruch, A
    Johnston, CM
    Martel, MK
    Robertson, JM
    Reynolds, KR
    Marsh, LH
    Roberts, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05): : 1087 - 1093
  • [7] CT-guided interstitial implantation of gynecologic malignancies
    Erickson, B
    Albano, K
    Gillin, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03): : 699 - 709
  • [8] TREATMENT OF CERVICAL-CARCINOMA EMPLOYING A TEMPLATE FOR TRANSPERINEAL INTERSTITIAL IR-192 BRACHYTHERAPY
    GADDIS, O
    MORROW, CP
    KLEMENT, V
    SCHLAERTH, JB
    NALICK, RH
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06): : 819 - 827
  • [9] HSU J, 2002, INT J RADIAT ONCOL, V52, P538
  • [10] PARAMETRIAL INTERSTITIAL BRACHYTHERAPY FOR ADVANCED OR RECURRENT PELVIC MALIGNANCY - THE HARVARD STANFORD EXPERIENCE
    HUGHESDAVIES, L
    SILVER, B
    KAPP, DS
    [J]. GYNECOLOGIC ONCOLOGY, 1995, 58 (01) : 24 - 27