Comparative in vitro performance of valved holding chambers with a budesonide/formoterol pressurized metered-dose inhaler

被引:7
作者
Chambers, Frank E. [1 ]
Brown, Steven [1 ]
Ludzik, Andrew J. [1 ]
机构
[1] AstraZeneca R&D Charnwood, Pharmaceut & Analyt R&D, Loughborough LE11 5RH, Leics, England
关键词
Asthma; budesonide/formoterol; corticosteroid; delivered dose; drug delivery; fine particle dose; long-acting beta(2)-adrenergic agonist; pressurized metered-dose inhaler; tidal breathing pattern; valved holding chamber; ELECTROSTATIC CHARGE; MULTIPLE ACTUATIONS; AEROSOL DELIVERY; PLASTIC SPACERS; DEVICES; BUDESONIDE; FORMOTEROL; EFFICACY; FACEMASK; THERAPY;
D O I
10.2500/aap.2009.30.3252
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
A combination of budesonide and formoterol in a single pressurized metered-dose inhaler (pMDI) is available in the United States and elsewhere. This study was designed to evaluate the delivered dose and fine particle dose (FPD; mass of particles <4.7-micrometer diameter) using the pMDI with two valved holding chambers (VHCs), using sampling methods reflecting different patient techniques. FPD was measured using an Andersen Cascade Impactor and delivered dose was measured using a disposable filter. Two VHCs, AeroChamber Plus and AeroChamber MAX (Trudell Medical International, London, Ontario, Canada), were evaluated using three sampling methods: (1) immediate collection; (2) collection after tip to a 5-second delay, (3) using simulated adult, child, and infant tidal breathing patterns (delivered dose). Decreases in delivered dose were observed using a VHC compared with the pMDI alone. FPD with both VHCs was similar to that with the pMDI alone with minimal delay between actuation and collection. With delays, the antistatic AeroChamber MAX was more resistant than AeroChamber Plus to dose losses. Delivered doses from adult and child profiles were comparable with those after a I-second delay. The infant profile produced lower delivered doses, probably because more breath cycles are required to empty the VHC. Budesonide/formoterol pMDI can be used effectively with AeroChamber Plus and the antistatic AeroChamber MAX. With minimal delay between actuation and collection, FPD with both VHCs was similar to that with the pMDI alone, giving physicians a choice of administration regimen and taking into account the needs and skills of the patient. (Allergy Asthma Proc 30:424-432, 2009; doi: 10.2500/aap.2009.30.3252)
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
[21]   Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber [J].
Demirkan, K ;
Tolley, E ;
Mastin, T ;
Soberman, J ;
Burbeck, J ;
Self, T .
CHEST, 2000, 117 (05) :1314-1318
[22]   Comparable long-term safety and efficacy of a novel budesonide/formoterol pressurized metered-dose inhaler versus budesonide/formoterol Turbuhaler® in adolescents and adults with asthma [J].
Morice, Alyn H. ;
Hochmuth, Ludek ;
Ekelund, Jan ;
Thoren, Anders ;
Puterman, Allan S. .
PULMONARY PHARMACOLOGY & THERAPEUTICS, 2008, 21 (01) :32-39
[23]   A Validated TLC-Densitometric Method for the Simultaneous Determination of Formoterol Fumarate and Budesonide in Pressurized Metered-Dose Inhaler [J].
Rizk, Mohammad ;
Sultan, Maha ;
Talaat, Nermeen ;
Youssef, Nadia .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2017, 30 (01) :63-67
[24]   A Validated TLC-Densitometric Method for the Simultaneous Determination of Formoterol Fumarate and Budesonide in Pressurized Metered-Dose Inhaler [J].
Mohammad Rizk ;
Maha Sultan ;
Nermeen Talaat ;
Nadia Youssef .
JPC – Journal of Planar Chromatography – Modern TLC, 2017, 30 :63-67
[25]   The effect of budesonide/formoterol pressurized metered-dose inhaler on predefined criteria for worsening asthma in four different patient populations with asthma [J].
Murphy K.R. ;
Uryniak T. ;
Martin U.J. ;
Zangrilli J. .
Drugs in R&D, 2012, 12 (1) :9-14
[26]   Efficacy and safety of budesonide/formoterol pressurized metered-dose inhaler: Randomized controlled trial comparing once- and twice-daily dosing in patients with asthma [J].
Berger, William E. ;
Bleecker, Eugene R. ;
O'Dowd, Liza ;
Miller, Christopher J. ;
Mezzanotte, William .
ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (01) :49-59
[27]   Budesonide/Formoterol Pressurized Metered-Dose InhalerIn Chronic Obstructive Pulmonary Disease [J].
Katherine A. Lyseng-Williamson .
Drugs, 2009, 69 :1459-1470
[28]   Lung deposition of budesonide from a pressurized metered-dose inhaler attached to a spacer [J].
Thorsson, L ;
Edsbäcker, S .
EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (06) :1340-1345
[29]   In vitro comparison of beclomethasone and salbutamol metered-dose inhaler aerosols inhaled during pediatric tidal breathing from four valved holding chambers [J].
Finlay, WH ;
Zuberbuhler, P .
CHEST, 1998, 114 (06) :1676-1680
[30]   Automatic replacement of albuterol nebulizer therapy by metered-dose inhaler and valved holding chamber [J].
Hendeles, L ;
Hatton, RC ;
Coons, TJ ;
Carlson, L .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (10) :1053-1061