Hysteretic behavior of cold-formed steel reinforced concrete shear walls with steel meshes

被引:3
作者
Xu, Zhifeng [1 ,2 ]
Du, Qiqi [1 ,2 ]
Chen, Zhongfan [3 ,4 ]
Chen, Haitao [2 ]
机构
[1] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Shandong Key Lab Civil Engn Disaster Prevent & Mit, Qingdao 266590, Peoples R China
[3] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, 02 Sipailou, Nanjing 210096, Peoples R China
[4] Southeast Univ, Sch Civil Engn, 02 Sipailou, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Cold -formed steel; Shear wall; Hysteretic behavior; Cyclic loading; Steel mesh; Restoring force model; LIGHTWEIGHT FOAMED CONCRETE; SEISMIC PERFORMANCE; PANELS; LAYER;
D O I
10.1016/j.jcsr.2022.107445
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To satisfy the requirements of hysteretic behavior of cold-formed steel (CFS) shear walls in mid-high buildings, a new type of cold-formed steel reinforced concrete (CSRC) shear wall with steel meshes on both sides is proposed in this study. Steel mesh is made of galvanized steel sheet by pressing holes, and there are horizontal ribbed stiffeners and rectangular grids arranged at equal intervals. Five full-scale specimens with different configurations were tested subjected to reversed cyclic loading to assess the failure mode, load-bearing capacity, ductility, lateral stiffness, energy dissipation and strain. The effects of the aspect ratio, the presence of horizontal reinforcing bars, the presence of X-shaped bracing, and the horizontal reinforcement ratio were analyzed. The results showed that the shear wall shows more pronounced flexural failure characteristics with the increase of the aspect ratio. Horizontal reinforcing bars could reduce the concentration of crack distribution and improve the shear capacity of the shear wall, whereas the increase of the horizontal reinforcement ratio from 0.35% to 0.65% had little effect on the hysteretic behavior of the wall in bending failure. The X-shaped bracing significantly improved the load-bearing capacity and moderated the pinching effect of the hysteresis curve before peak load, but reduced the ductility of the wall. Finally, the restoring force model based on the experimental data and theoretical analysis was established, and the hysteretic behavior of CSRC shear walls was well predicted.
引用
收藏
页数:22
相关论文
共 53 条
  • [1] American Iron and Steel Institute (AISI), 2007, S213 AISI
  • [2] [Anonymous], 2019, The Chinese National Standard GB/T 50081
  • [3] [Anonymous], 2011, 22812010 GBT
  • [4] [Anonymous], 2015, 1012015 JGJT
  • [5] Bohl A, 2011, ACI STRUCT J, V108, P148
  • [6] Postearthquake fire experiments of cavity-insulated cold-formed steel load-bearing walls lined with plasterboards
    Chen, Wei
    Ye, Jihong
    Wang, Qiang
    Jiang, Jian
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
  • [7] Postearthquake fire performance of cavity-insulated CFS shear walls with gypsum and calcium-silicate sheathing
    Chen, Wei
    Ye, Jihong
    Wang, Qiang
    Jiang, Jian
    Qin, Yafei
    [J]. THIN-WALLED STRUCTURES, 2020, 148 (148)
  • [8] Clough RW, 1966, P JAP EARTHQ ENG S, V1, P1
  • [9] Federal Emergency Management Agency (FEMA), 2000, PREST COMM SEIS REH
  • [10] Seismic performance of cold-formed steel framed shear walls with steel sheathing and gypsum board
    Feng, Ruo-qiang
    Zhu, Baochen
    Xu, PengHui
    Qiu, Yun
    [J]. THIN-WALLED STRUCTURES, 2019, 143