Assessment of a novel heat-driven cycle to produce. shaft power and refrigeration

被引:13
作者
Alelyani, Sami M. [1 ]
Sherbeck, Jonathan A. [1 ]
Fette, Nicholas W. [1 ]
Wang, Yuqian [1 ]
Phelan, Patrick E. [1 ]
机构
[1] Arizona State Univ, Sch Engn Matter Transport & Energy, 501 E Tyler Mall,ECG303, Tempe, AZ 85287 USA
关键词
Tri-generation; Polygeneration; Combined cooling and power; Combined cooling heating and power; PERFORMANCE; DESIGN; DEHUMIDIFICATION; POLYGENERATION; STRATEGY;
D O I
10.1016/j.apenergy.2018.02.035
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a novel combined cooling and power (CCHP) system based on a composition of a Rankine, gas refrigeration (reverse Brayton), liquid desiccant, ejector, and evaporative cooling cycles. The two proposed configurations, called the original cycle (OC) and the enhanced cycle (EC), utilize heat rejected by the Rankine cycle via its condenser in order to regenerate the liquid desiccant cycle. The desiccant cycle allows the cooling systems to decouple sensible and latent loads, and potentially reduce water consumption relative to pure evaporative cooling. Based on our thermodynamic calculations, the OC and EC are more feasible from an energy saving viewpoint compared with separate systems that provide the same services for sensible heat ratios (SHR) less than 14% and 39%, respectively. At a fixed heat source input of about 2.4 MWth at 210 degrees C, the OC is capable of generating 103 kW(e) of electrical power, 181 kW(th) of sensible cooling, 1631 kW(th) of latent cooling capacity, and fresh water at 2.7 m(3)/h capacity. At a SHR of 10%, the OC can achieve an exergy efficiency and primary energy saving ratio (PESR) of 24% and 28%, respectively. Similarly, and at the same thermal energy input, the EC can supply 354 kW(e), 400 kW(th), and 1199 kWth, and 1.8 m(3)/h of electrical power, sensible cooling capacity, latent cooling capacity, and fresh water capacity, respectively, at a SHR of 25%. Furthermore, the EC is more efficient than both the OC and stand-alone conventional systems as it shows a higher exergy efficiency of 53% and PESR of 29%.
引用
收藏
页码:751 / 764
页数:14
相关论文
共 25 条
  • [1] Review of tri-generation technologies: Design evaluation, optimization, decision-making, and selection approach
    Al Moussawi, Houssein
    Fardoun, Farouk
    Louahlia-Gualous, Hasna
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 120 : 157 - 196
  • [2] Techno-economic analysis of combined ammonia-water absorption refrigeration and desalination
    Alelyani, Sami M.
    Fette, Nicholas W.
    Stechel, Ellen B.
    Doron, Pinchas
    Phelan, Patrick E.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 143 : 493 - 504
  • [3] Calise F., 2016, Simulation of Polygeneration Systems
  • [4] Cengel Y.A., 2002, SEA, V1000, P8862
  • [5] Combined cooling, heating and power: A review of performance improvement and optimization
    Cho, Heejin
    Smith, Amanda D.
    Mago, Pedro
    [J]. APPLIED ENERGY, 2014, 136 : 168 - 185
  • [6] Properties of aqueous solutions of lithium and calcium chlorides: formulations for use in air conditioning equipment design
    Conde, MR
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (04) : 367 - 382
  • [7] A review of combined power and cooling cycles
    Demirkaya, Goekmen
    Vasquez Padilla, Ricardo
    Goswami, D. Yogi
    [J]. WILEY INTERDISCIPLINARY REVIEWS-ENERGY AND ENVIRONMENT, 2013, 2 (05) : 534 - 547
  • [8] Smart polygeneration grids: experimental performance curves of different prime movers
    Ferrari, Mario L.
    Traverso, Alberto
    Massardo, Aristide F.
    [J]. APPLIED ENERGY, 2016, 162 : 622 - 630
  • [9] Emission operational strategy for combined cooling, heating, and power systems
    Fumo, Nelson
    Mago, Pedro J.
    Chamra, Louay M.
    [J]. APPLIED ENERGY, 2009, 86 (11) : 2344 - 2350
  • [10] Quick performance prediction of liquid desiccant regeneration in a packed bed
    Gandhidasan, P